1,  Generating Set Model: P175HE

2,  Engine Make & Model:Perkins 1306-E87T215

3,  Alternator Model:LL3014H

3,  Circuit Breaker Type:3 Pole MCCB

4,  Frequency:50 Hz / 60 Hz

5,  Cycle:  4 Stroke

6,  Engine Speed:1800 rpm

7,  Cooling Method:  Water

8,  Governing Type:  Electronic

9,  Output Type: AC Three Phase

10,Base Frame Type:Heavy Duty FabriCAT-parts-partsed Steel

 

 

3 Pole MCCB Portable Genset Diesel Generator , 185 kVA Generator

 

Output Ratings

Generating Set Model

*                               P175HE Prime*                     Standby*

380-415V, 50 Hz

-                               -

-                               -

480V, 60 Hz

169.0 kVA                185.0 kVA

135.2 kW                 148.0 kW

  • Refer to ratings definitions on page 4.

           Ratings at 0.8 power factor.

 

Technical Data

Engine Make & Model:

Perkins 1306-E87T215

Alternator Model:

LL3014H

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCCB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

-                      1800

Fuel Tank Capacity: litres (US gal)

350 (92.5)

Fuel Consumption:  P160H    l/hr (US gal/hr)

-               41.8 (11.0)

Fuel Consumption:   P175HE   l/hr (US gal/hr)

-               43.7 (11.5)

P160H / P175HE

 

 

Engine Technical Data

 

Physical Data       

 

Manufacturer:                             Perkins

Model:                                  1306-E87T215

No. of Cylinders/Alignment:      6 / In Line

Cycle:                                        4 Stroke

Induction:                              Turbocharged

Cooling Method:                          Water

Governing Type:                      Electronic

Governing Class:                  ISO 8528 G2

Compression Ratio:                    17.2:1

Displacement: l (cu.in)            8.7 (530.9)

Bore/Stroke: mm (in)

                                      116.6 (4.6)/135.9 (5.4)

Moment of Inertia: kg m² (lb. in²)  

                                               1.54 (5266)

Engine Electrical System:

-Voltage/Ground:                   24/Negative

-Battery Charger Amps: 45

Weight: kg (lb)

-                                         Dry:  671 (1479)

-                                         Wet: 698 (1539)

 

Air System 

 

Air Filter Type:                     Replaceable

Element Combustion Air Flow: m³/min (cfm)       

-Standby:                              18.0 (636)

-Prime:                                  20.6 (727)

Max. Combustion Air Intake Restriction: kPa (in H2O)                     6.2 (24.9)

Radiator Cooling Air Flow:m³/min (cfm)                                    414.0 (14620)

External Restriction to Cooling Air Flow: Pa (in H2O)                       125 (0.5)

 

Cooling System

 

Cooling System Capacity:l (US gal)                                                36.8 (9.7)

Water Pump Type:                                                                        Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby:                                                                                     88.5 (5033)

-Prime:                                                                                         79.4 (4515)

Heat Radiation to Room:kW (Btu/min)       

-Standby:                                                                                                                     52.0 (2957)

-Prime:                                                                                         45.1 (2565)

Radiator Fan Load: kW (hp)                                                           2.0 (16.1)

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

Contact your local FG Wilson dealer for power ratings at specific site conditions.

 

Performance  

 

Engine Speed:                                                 RPM 1800

Gross Engine Power: kW (hp)

-Standby:                                                      171.5 (230.0)

-Prime:                                                          156.0 (209.0)

BMEP: kPa (psi)

-Standby:                                                    1313.0 (190.5)

-Prime:                                                        1194.0 (173.2)

Regenerative Power:                                       kW 28.6

 

 

LubriCAT-parts-partsion System

 

Oil Filter Type:                                        Spin-On, Full Flow

Total Oil Capacity l (US gal):                         26.4 (7.0)

Oil Pan l (US gal):                                         22.7 (6.0)

Oil Type:                                                 API CG4 15W-40

Cooling Method:                                               Water

 

 

Fuel System

 

Fuel Filter Type:                                         Replaceable

Element Recommended Fuel:                 Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

110%              100%               75%                50%

Load               Load               Load               Load

P160H

50 Hz                 -                      -                       -                      -

60 Hz         43.7 (11.5)      41.8 (11.0)   

                   34.7 (9.2)        24.9 (6.6)

P175HE

50 Hz                                        -                       -                      -

60 Hz                                43.7 (11.5)       37.0 (9.8)        26.9 (7.1)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

 

 

Exhaust System  

 

Silencer Type:                                            Level 1

Silencer Model & Qty:               SD100 (1) Pressure Drop Across

Silencer System: kPa (in Hg)                  8.70 (2.569)

Silencer Noise ReductionLevel:                  DB10

Max. Allowable Back Pressure:         kPa (in. Hg)  10.7 (3.2)

Exhaust Gas Flow: m³/min (cfm)       

-Standby:                                              43.0 (1519)

-Prime:                                                  47.2 (1667)

Exhaust Gas Temperature:  °C (°F) m³/min (cfm)       

-Standby:                                                407 (765)

-Prime:                                                    322 (611)

P160H / P175HE

 

 

Alternator Performance Data

 

Data Item

             50 Hz                                            60 Hz

480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

230/115V

440/254V

220/127V

Motor Starting Capability* kVA

420

282

330

309

363

Short Circuit Capacity** %

-

-

-

-

-

Reactances: Per Unit

Xd X'd X''d

2.610

0.090

0.053

4.140

0.140

0.083

3.480

0.120

0.070

3.760

0.130

0.076

3.110

0.100

0.063

 

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

      ** With optional Permanent Magnet generator or AREP excitation.

 

 

Alternator Technical Data

 

Physical Data                                                                   Operating Data

Manufacturer:  FG WILSON

Overspeed: RPM 2250

Model:  LL3014H

Voltage Regulation (steady state) (%): + /- 0.5

No. of Bearings:  1

Wave Form NEMA = TIF: 50

Insulation Class:  H

Wave Form IEC = THF: 2.0%

Winding Pitch Code:  2/3 - 6

Total Harmonic Content LL/LN:    4.0%

Wires: 12

Supression is in line with European Standard

Radio Interference: EN61000-6

Ingress Protection Rating:   IP23

Radiant Heat: kW (Btu/min)

-50 Hz:                                           -

-60 Hz:                                   11.0 (626)

Excitation System: SHUNT

AVR Model:R230

P160H / P175HE

 

 

Technical Data

 

3 Phase Ratings and Performance at 50 Hz,   -RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM

 

 

 

Voltage         Prime Model    Standby Model        Voltage          Prime Model             Standby Model

        -                                  -                                                           P160H                         P175HE

kVA                 kW

kVA                 kW

 

kVA                 kW

kVA                  kW

 

 

220/127V

169.0              135.2

185.0              148.0

 

 

380/220V

168.0              134.4

185.0              148.0

 

 

240/120V

169.0              135.2

185.0              148.0

 

 

230/115V

169.0              135.2

185.0              148.0

 

 

440/254V

169.0              135.2

185.0              148.0

 

 

220/110V

168.0              134.4

185.0              148.0

 

 

208/120V

169.0              135.2

185.0              148.0

 

 

Definitions

Standby Rating

 

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


 

Prime Rating

 

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 

 


 

Weights and Dimensions

 

Weights: kg (lb)                                                             Dimensions: mm (in)

 

 

Net (+ lube oil)

 

1865 (4112)

 

Length

 

2960 (116.5)

Wet (+ lube oil & coolant)

1902 (4193)

Width

1003 (39.5)

Fuel, lube oil & coolant

2197 (4844)

Height

1718 (67.6)

 

 

 

General Data

 

Documents

 

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.



 

Generating Set Standards

 

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.


 

Warranty

 

All equipment carries full manufacturer's warranty.

 

Hot Products

1, Model:DCEC Cummins 6BTA5.9-G2, 4-cycle 2, Air Intake System:Turbo, Water/Air Cooling 3, Fuel ...
1, Model:DCEC Cummins 4BTA3.9-G2, 4-cycle 2, Air Intake System:Turbo, Water/Air Cooling 3, Fuel ...
1, Generating Set Model:P250HE 2, Engine Make & Model:Perkins 1306-E87TA300 3,Alternator Model...
1, Generating Set Model: P175HE 2, Engine Make & Model:Perkins 1306-E87T215 3, Alternator Model...
1, Generating Set Model: JPP150E 2, Engine Make & Model:Perkins 1006TAG 3, Alternator Model:LL3014F ...
1, Generating Set Model: JPP100E 2, Engine Make & Model:Perkins 1006TG1A 3,Alternator Model:LL3014B ...