Home Companies Guangdong ALI Testing Equipment Co,.Ltd

60Hz Perkins Diesel Generator , 3 Pole ACB , P2200E , Three Phase

Guangdong ALI Testing Equipment Co,.Ltd
Active Member

Contact Us

[China] country

Address: No. 2, Shajiao Sijia Gate, Humen Town, Dongguan City, Guangdong Province, China

Contact name:Kris

Inquir Now

Guangdong ALI Testing Equipment Co,.Ltd

60Hz Perkins Diesel Generator , 3 Pole ACB , P2200E , Three Phase

Country/Region china
City & Province dongguan guangdong
Categories Diesel Generators
InquireNow

Product Details


1, Engine Make & Model:Perkins 4016TAG2A

2,Generating Set Model:  P2200E

3,Alternator Model:LL9124H

4, Circuit Breaker Type:           3 Pole ACB

5, Frequency:                          50 Hz / 60 Hz

6,Cycle:                                       4 Stroke

7, Engine Speed:                      1500rpm
    
8, Cooling Method:          Turbo, Water/Air cooling

9, Governing Type:                    Electronic

10, Output Type:                  AC Three Phase

10, No.of Cylinders/Alignment:  16 / Vee

11,Base Frame Type:   Heavy Duty FabriCAT-parts-partsed Steel

 

P2200E Perkins Diesel Generator , 3 Pole ACB

 

Output Ratings

Generating Set Model

*P2200E     Prime*                     Standby*

380-415V, 50 Hz

2000.0 kVA              2200.0 kVA

1600.0 kW               1760.0 kW

220/127V, 60 Hz

 

-                               -

-                               -

  • Refer to ratings definitions on page 4.

            Ratings at 0.8 power factor.

Technical Data

Engine Make & Model:

Perkins 4016TAG2A

Alternator Model:

LL9124H

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole ACB

Frequency:

50 Hz           60 Hz

Engine Speed: RPM

1500                   -

Fuel Tank Capacity: litres (US gal)

-

Fuel Consumption:  P2000     l/hr (US gal/hr)

423.5 (111.9)             -

Fuel Consumption:   P2200E    l/hr (US gal/hr)

474.1 (125.2)             -

P2000 / P2200E

 

Engine Technical Data

 

Physical Data                                                                 Air System                                   50 Hz           60 Hz

 

 

Manufacturer:                                                     Perkins

Model:                                                             4016TAG2A

No. of Cylinders/Alignment:                          16 / Vee

Cycle:                                                                 4 Stroke

Induction:                           Turbocharged Air To Air Charge Cooled

 

Cooling Method:                                      Water Governing

Type:                                                         Electronic Governing

Class:                                                          ISO 8528 G2

Compression Ratio:                                         13.6:1

Displacement: l (cu.in)                                61.1 (3730.0) Bore/Stroke: mm (in)                           160.0 (6.3)/190.0 (7.5) Moment of Inertia: kg m² (lb. in²)              20.72 (70803)

Engine Electrical System:

-Voltage/Ground:                                          24/Negative

-Battery Charger Amps:                                       40

Weight: kg (lb) - Dry:                                     5570 (12280)

- Wet:                                                               5847 (12890)

 

Air Filter Type:                                           Replaceable Element Combustion

Air Flow:

m³/min (cfm)       

-Standby:             145.0 (5121)             -

-Prime:                137.0 (4838)            

- Max. Combustion Air Intake

Restriction: kPa (in H2O)                      3.7 (14.9)               

- Radiator Cooling Air Flow:

m³/min (cfm)          2058.0 (72678)          

- External Restriction to

Cooling Air Flow: Pa (in H2O)                250 (1.0)                -

 

Cooling System                             50 Hz           60 Hz

 

 

Cooling System Capacity:l (US gal)                    355.0 (93.8)             

- Water Pump Type:                                               Centrifugal Heat Rejected to Water &

Lube Oil: kW (Btu/min)

 

-Standby:           721.0 (41003)            -

-Prime:               660.0 (37534)           

- Heat Radiation to Room:

kW (Btu/min)     -Standby:    231.0 (13137)            -

-Prime:                                    200.0 (11374)           

- Radiator Fan Load: kW (hp)   63.5 (85.2)               -

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

 

Performance                          50 Hz         60 Hz

 

Engine Speed: RPM                                 1500                       - Gross Engine Power: kW (hp)

-Standby:      1937.0 (2597.6)              -

-Prime:       1766.0 (2368.2)              - BMEP: kPa (psi)

-Standby:       2535.2 (367.7)                -

-Prime:        2311.1 (335.2)                - Regenerative Power: kW                          160.0                       -

 

LubriCAT-parts-partsion System

 

 

Oil Filter Type:      Spin-On, Full Flow

Total Oil Capacity l (US gal):  238.0 (62.9)

Oil Pan l (US gal):      214.0 (56.5)

Oil Type:                   API CG4 15W-40

Cooling Method:                 Water

 

Fuel System

 

 

Fuel Filter Type:                    Replaceable Element Recommended

Fuel:                                                            Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

 

110%              100%               75%                50% Load               Load               Load               Load

P2000

 

50 Hz      474.1 (125.2)  423.5 (111.9)   312.9 (82.7)    212.9 (56.2)

60 Hz                 -                      -                       -                      -

 

 

P2200E

 

50 Hz                              474.1 (125.2)   344.9 (91.1)    232.1 (61.3)

60 Hz                                        -                       -                      -

 

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

 

Exhaust          50 Hz           60 Hz

 

 

Silencer Type:                        Level 1

Silencer Model & Qty:        SD350 (1)

Pressure Drop Across

Silencer System: kPa (in Hg)               0.50 (0.148)             

- Silencer Noise Reduction

Level: dB                                    17                     

- Max. Allowable Back

Pressure: kPa (in. Hg)       6.6 (1.9)                

- Exhaust Gas Flow:

m³/min (cfm)       

-Standby:           387.0 (13667)            -

-Prime:                387.0 (13667)            - Exhaust Gas Temperature:  °C (°F)

m³/min (cfm)       

-Standby:               493 (919)                -

-Prime:                   493 (919)                

 

P2000 / P2200E

Alternator Performance Data

 

 

Data Item

50 Hz                                                            60 Hz

415/240V

400/230V

380/220V

 

 

Motor Starting Capability* kVA

 

 

6986

 

 

6509

 

 

5897

 

 

Short Circuit Capacity** %

 

 

 

300

 

 

 

300

 

 

 

300

 

 

Reactances: Per Unit

 

 

Xd X'd X''d

 

 

 

 

 

 

3.230

 

0.240

 

0.126

 

 

 

 

 

 

3.480

 

0.260

 

0.136

 

 

 

 

 

 

3.850

 

0.290

 

0.151

Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.

 

Alternator Technical Data

 

Physical Data                                                                   Operating Data

 

Manufacturer:                                                   FG WILSON

 

Overspeed: RPM                                                     2250

 

Model:                                                                 LL9124H

 

Voltage Regulation (steady state) (%):                   + /- 0.5

 

No. of Bearings:                                                       1

 

Wave Form NEMA = TIF:                                         50

 

Insulation Class:                                                      H

 

Wave Form IEC = THF:                                         2.0%

 

Winding Pitch Code:                                          2/3 - 6S

 

Total Harmonic Content LL/LN:                         2.5%

 

Wires:                                                                        6

Supression is in line with European Standard

Radio Interference:       EN61000-6

 

Ingress Protection Rating:                                        IP23

 

Radiant Heat: kW (Btu/min)

 

 

-50 Hz:                                  81.0 (4606)

 

-60 Hz:                                           -

 

Excitation System:                                                  AREP

 

AVR Model:                                                             R449

P2000 / P2200E

 

Technical Data

3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz-    RPM

 

 

Voltage         Prime Model                Standby Model          Voltage          Prime Model                Standby Model

P2000                         P2200E                                            -                                  -

 

kVA                 kW

kVA                 kW

 

kVA                 kW

kVA                  kW

415/240V

2000.0            1600.0

2200.0            1760.0

 

 

 

400/230V

2000.0            1600.0

2200.0            1760.0

 

 

 

380/220V

2000.0            1600.0

2200.0            1760.0

 

 

 

 

Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

 

Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

 

Weights and Dimensions

 

Weights and Dimensions

 

General Data

 

Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.

 

Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.

 

Warranty

All equipment carries full manufacturer's warranty.

 

 

Hot Products

Alternator Brand:Original Stamford Alternator Model:UCI274C Prime Power:80KW / 100KVA Frequency:50HZ ...
150kva Volvo Generator Diesel( JP-V120) Volvo Engine: TAD731GE Prime Power: 150KVA/120KW 150kva ...
Standby power:200 kW Prime power:182 kW Rated speed:1800 RPM Phase:3 Rated voltage:480 V 6 Cylinder ...
Model:TAD940GE Cylinder Arrangement:6 in line Air Intake System:Turbo Rated Power:240KW 240KW Single ...
Genset Model:JP-V250 Genset Output Power:250KW Rated Voltage:380/220V Frequency:50hz 4 stroke Volvo ...
​ 400KW IP21 Volvo Diesel Generator , Turbo Charged Generator Brand:VOLVO Genset Model:JP-V400 ...