Henan Chicheng Electric Co.,Ltd |
Characteristic features:
▲ small size, light weight (10.7x6.0x3.6cm/160 g)
▲ single button, simple operation
▲ with 16 hours of data logging and event logging 10
▲ integral anti-vibration jacket for harsh environments
▲ LCD display continuous real-time gas concentrations
▲ standard rechargeable lithium battery (charging no more than
three hours to meet the 14 hours of work)
▲ 95dB alarm sound and wide-angle bright light alarm
▲ with vibration alarm for high noise environment
▲ background light: low light in the alarm and automatically open
▲ low, high, TWA and STEL alarm level 4; over range alarm
▲ simple automatic calibration process
▲ Records TWA, STEL and maximum exposure, need to show
▲ multi-mode selection, adapt to the user application
▲ full-function self-test: sensor, battery, circuit and alarm
functions
▲ random configuration: sensor, lithium battery and charger,
stainless steel alligator clip, calibration cap and hose,
instructions
Specifications
◆ Inspection gases test 2,3,4
◆ automatic calibration and zero calibration
◆ Backlight in low light / alarm to open automatically when the
backlight
◆ plug-type sensors, electrochemical sensors (gas and oxygen);
Catalytic Combustion (LEL)
◆ content STEL time period can be set (5-15 minutes); calibration
gas concentration, calibration cycle, open or close a gas; to work
on or off beep sound, auto-zero start, alarm lock, "Safety" display
function, mute function, test function test forced expired,
◆ calibration cycle settings, selection of gas units.
◆ Alarm indicator sound, light and vibration are three Alarm
◆ Wide flashing light alarm light
◆ alarm sound changes 95dB (30cm) sound pulse
◆ Vibration alarm pulse vibration
◆ Other low battery alarm, over range, sensor failure alarm
◆ alarm set point is displayed when booting
◆ LCD display of gas concentration and the continuous real-time
status
◆ STEL / TWA STEL and TWA values of records required to display
◆ Max records the maximum exposure needed to display
◆ Full function self-test automatically after boot detection
sensor, battery, circuit and alarm functions
◆ battery life for more than 14 hours, charge 3 hours
◆ Temperature -20 ℃ - +58 ℃
◆ humidity 5% - 95% RH (non-condensing)
◆ EMI / RFI standards compliance EMC 89/336/EEC
◆ Dimensions 10.7x 6.0 x 3.6cm
◆ Weight 160 grams
◆ riot rating IP66/67
◆ event log can record more than 10 alarm events, including the
type of gas, the maximum exposure value, alarm duration, etc.
◆ Data Logger users can download the data logger, and rolling
16-hour recorded information, the default interval of 15 seconds
recording time
◆ Sensor Life O2 ≥ 2, the other ≥ 3 years
Detector Model | Gas Detected | Range | Range Optional | Resolution | Responding Time |
CO Detector | CO | 0-1000ppm | 0-500/2000/5000ppm | 1ppm | ≤20s |
O2 Detector | O2 | 0-25%VOL | 30%VOL | 0.1%VOL | ≤20s |
O3 Detector | O3 | 0-10ppm | 0-100ppm | 0.01ppm | ≤20s |
H2S Detector | H2S | 0-100ppm | 0-50/200/1000ppm | 1ppm | ≤30s |
H2 Detector | H2 | 0-1000ppm | 0-5000ppm | 1ppm | ≤30s |
CL2 Detector | CL2 | 0-20ppm | 0-10/100ppm | 0.1ppm | ≤30s |
NH3 Detector | NH3 | 0-100ppm | 0-50/500/1000ppm | 1ppm | ≤30s |
SO2 Detector | SO2 | 0-20ppm | 0-50、1000ppm | 0.1ppm | ≤30s |
NO Detector | NO | 0-25ppm | 0-500ppm | 0.1ppm | ≤30s |
NO2 Detector | NO2 | 0-20ppm | 0-50/100ppm | 0.1ppm | ≤30s |
CH2O Detector | CH2O | 0-50ppm | 0-5/10ppm | 0.01ppm | ≤30s |
HCL Detector | HCL | 0-20ppm | 0-20/100ppm | 0.5ppm | ≤30s |
Flammable Gas Detector | EX | 0-100%LEL | 0-100%LEL | 1% | ≤30s |
For the gas that is not covered here though, please don’t hesitate to contact us. |