Enviro Solutions Technology Co.,Ltd |
Verified Suppliers
|
|
The Zirconia Oxygen/Humidity Analyzer Is Designed With A High-Temperature Resistant Structure,Humidity And Oxygen Output
A zirconia oxygen analyzer is a device that measures the concentration of oxygen in a gas sample. Zirconia oxygen analyzers are used in a variety of applications, including environmental monitoring, industrial process control, and medical diagnostics.
Zirconia oxygen analyzers work by measuring the change in
electrical resistance of a zirconia ceramic sensor as the oxygen
concentration changes. The sensor is heated to a high temperature,
and the oxygen molecules in the gas sample react with the zirconia
to form a new compound. This change in chemical composition causes
the sensor to change its electrical resistance.
The electrical resistance of the sensor is measured by a Wheatstone
bridge circuit. The output of the Wheatstone bridge circuit is
proportional to the oxygen concentration in the gas sample.
Zirconia oxygen analyzers are accurate and reliable, and they are
relatively inexpensive to operate. However, they can be affected by
the presence of other gases, such as carbon monoxide and hydrogen
sulfide.
Here are some of the advantages and disadvantages of zirconia
oxygen analyzers:
**Advantages:**
- Accurate and reliable
- Relatively inexpensive to operate
- Easy to use
- Compact and portable
**Disadvantages:**
- Can be affected by the presence of other gases
- Can be damaged by high temperatures
- May require periodic calibration
1. Using self-developedThe third generation of solid electrolyte oxygen measurement technology
2. Longer field service life and stronger corrosion resistance
3. Meet the simultaneous online monitoring requirements of two factors of humidity and oxygen
4. The product adds the air one-key calibration function, which makes the instrument calibration operation simple and efficient
5. Humidity, oxygen volume percentage output, meet environmental protection technical requirements
Measuring Principle | Limiting Current Method |
Detection Range | H2O 0~40 %VOL
O2 0~25 %VOL (optional) |
Measurement Accuracy | H2O ±2% FS
O2 ±1% FS (optional) |
Repeatability | ±1%FS |
Response Time | T90 < 20s |
Sampling Method | plug-in |
Installation Method | Standard DN65 flange, other specifications can be customized |
Rod Length | Standard length 800mm, other specifications can be customized |
Flue Gas Temperature | 0~250℃, 0~500℃ (can be customized) |
Display Method | LCD screen display, inside the instrument case |
Oxygen Calibration | Support oxygen zero point and span calibration (optional) |
Humidity Calibration | Support humidity zero point and span calibration |
Power Supply | 220VAC±10% 50HZ, 24W |
Ambient Temperature | -20℃~50℃ |
Environment Humidity | 5%~100% RH |
Degree Of Protection | IP65 |
Storage Temperature | -40℃~70℃ |
Storage Humidity | 5%~95% RH |