1. Temperature, humidity, date(year,mouth,day), clock, with
screen display
2. Clock for 12/24 hours
3. Daily alarm.The whole point timekeeping function
4. ℃/℉temperature display.The temperature and humidity of
the maximum and minimum memory
5. Luminous function
6. Temperature measurement range:0℃~50℃(-32℉~122℉)
7. Temperature display resolution:0.1℃(0.2℉)
8. The temperature measurement precision:±0.5℃(0℃~50℃), the
other is ±1℃
9. Humidity measurement range: 10%RH~99%RH
Operating instructions :
1. The night opens:Shake the body light luminous,
automatically extinguished after 5 seconds.
2. Switching temperature unit:
Press the [℃/℉] buttonto switch temperature display unit.
3.Checkand clean the memory:
Press the [MEMORY] memory button can check the maximum
(MAX)/minimum (MIN) temperature and humidity value in the memory.
When showed Maximum (MAX)/ minimum (MIN) temperature and humidity
value in display, long press the [MEMORY] memory button to clean
the maximum (MAX)/minimum (MIN) temperature and humidity value in
the memory.
4. The date and clocksetting:
When display the clock,long press the [MODE] button start to set
the clockfollowed by minutes→hours→12∕24hours→year→mouth→day, press
the [ADJ] key to adjust, then press the [MODE] button to confirm
the clock and date.
5.The alarm time setting:
When display the clock,short press [MODE]buttonto switch to
the alarm display,and then long press the [MODE] button start to
set thealarm timefollowed byminutes→hours, press the [ADJ]buttonto
adjust. Then press the [MODE] button again to confirm the alarm
time setting mode.
6.The alarm clock and the whole point timekeeping opening and
closing
When display the clock,short press [MODE]buttonto switch to
the alarm display, and then press the [ADJ]buttonto open and close
alarm clock or the whole point timekeeping, followed by the alarm
clock opened->the whole point timekeeping opened->both the
alarm clock and the whole point timekeeping opened-> both the
alarm clock and the whole point timekeeping closed.