Product Details

 

Electric Fan Motor Axial Ceramic Case Resistor Type Temperature Fuse Thermal Cutoff Fuse

 

Structure
The thermal fuse is composed of ceramic shell, low melting point alloy wire, special resin, pin copper wire and sealing resin.

 

Apprearance
The marking must be clear; the sealing resin should fill the mouth and it is acceptable; the lead tin-plated layer is good; there is no oxidized black spot damage; the shell has no damage marks, perforations, etc.

 

No.Rated operating temperature
Tf(℃)
Hold temperature
Tc(℃)
Limit temperature Tm
(℃)
Measured operating temperature
(℃)
Rated voltage    (V)Rated current
In(A)
Y2011587150112±32502

 

Dimensions
abcd
9.5±0.580±50.5±0.22.5±0.1

 

 

Name

Thermal Fuse

 

 

Applicable Standards

 

Test items

Unit

Safety standard

Testing equipment

Action temperature detection

+0
TF
-10

thermotank

High pressure test

V

1000+2 times the rated voltage

Withstand voltage tester

Insulation resistance detection

MΩ

>2

Digital Megger

Internal resistance detection

Ω

<0.028

Bridge resistance tester

High pressure test after temperature check

V

>500

Withstand voltage tester

Insulation resistance test after temperature test

MΩ

>0.2

Digital Megger

Distortion detection

Each lead is bent 90° at a distance of 10mm from the thermal fuse, and then twisted in the opposite direction by 180° without damaging the components.

Manual operation

 

Experimental Method
The experimental conditions are temperature 25±10℃, humidity 65±15%M
1 Action humidity accuracy: Rely on the IE691: 1995 inspection method and measure with the built-in silicone oil pool in the thermostat.
2 Size: Measure the finished product with a micrometer/vernier ruler.
3 Appearance: visual inspection.
4 Insulation resistance: Measure the finished product with SP-3A digital megohmmeter, and measure the voltage DC500V.
5 Withstand voltage: Use the ZNY-12 withstand voltage test to determine the finished product, which takes 1 minute.
6 Tensile force: Measure the finished product with a push-pull tester, and the pin bears 1.5 pounds of pulling force for 10 minutes without damaging the components.
7 Torsion: Bend the lead at 10mm at 90°C, and then reverse it at 180°C without damaging the component.

 

Test Requirements
1. Rated operating temperature (Tf): The temperature at which the thermal fuse is tested according to the standard method to change its conductive state. (The Japanese Electrical Appliances Management Law stipulates that the tolerance range is ±7℃ for operation).
 

2. Measured operating temperature: The temperature fuse is heated in the silicone oil bath at a rate of 0.5-1°C per minute, and the fusing temperature obtained when the detection current is less than 100MA. It is the actual temperature of the thermal fuse.
 

3. Holding temperature (Tc): The maximum temperature at which the thermal fuse can maintain 168 hours without changing its conductive state when passing the rated current.
 

4. Limit temperature (Tm): The maximum temperature at which the thermal fuse can withstand 10 minutes without reconnection.
 

5. Rated voltage (Ur): The highest working voltage of the thermal fuse.

Hot Products

E521 E522 E523 28V DC Metal Case Stud Type Overload Protector Modified Reset Bimetal Circuit Breaker ...
E511 E512 E513 5A to 50A 12V 28V DC Metal Cabinet Stud Automatic Reset Type Circuit Breaker E511 ...
Plastic Case Cabinet Stud Bracket Mount 5A 10A 20A 30A 40A 50A Overload Protector Bimetal Automotive ...
E3 Series Mini Blade Type Plug-in Automatic Reset Car Automotive DC Circuit Breaker E31 is a single ...
E87 E88 E89 Auto Manual Reset Maxi Blade Fuse Plug-in Resettable Type Car Circuit Breaker Applicatio...
E77 E78 E79 Car Overload Protector Blade Fuse Automatic Manual Reset Automotive Circuit Breakers ...