5x17mm Micro Temperature Sensor , 15KOhm Probe Type Temperature Sensor

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

 

Electric Underfloor Heating Floor Micro Temperature Sensor Probe 5x17mm 15KOhm 3470 With IP68 Rated Waterproof

 

 

Dimension (Unit:mm)

 

Dimension
ABCDL
51725±53±1as required
 

 

Material List

 

NOMaterial NameMaterial and Specifications
2-1.ElementR25=15KΩ±1% B25/50=3470K±1% DC
2-2.CoatingNTC encapsulated using PVC over-mold material (Black)
2-3Cable featuresCustomization 2464-22#*2C Black hard round sheath wire (OD3.3)
2-4.Wire ends

Tinned

 

 

Important Note

 

This sensor has a resistance of 15,000 Ohms at 25ºC. Therefore it is not compatible with certain brands of underfloor heating thermostats such as Devi which have a resistance reading of 10k Ohms at 25°C. Please contact us if you are unsure or have any questions regarding this sensor.We have both type : 10k Ohms at 25°C and 15,000 Ohms at 25ºC.

 

______________________________________________________________________________Epoxy Coated Photocell 11mm Diameter Photoresistor Light Sensor GM11528 With Light Resistance 10-20 KOhm Download________

 

 

Description

 

All Comfort Heat thermostats include a floor sensor maintaining consistent floor temperature. Floor sensing thermostats are the safest and most energy efficient floor heating regulators ensuring the floor does not overheated, and kept at the desired temperature.

Replacement floor temperature sensor suitable for a wide range of underfloor heating thermostats.

An electric underfloor heating remote probe used to control floor or air temperature where moisture might be a problem (For example in a wet room or bathroom.) The sensor can also be used to control floor temperature where overheating would cause damage. The underfloor heating probe is compatible with all of our electric floor heating thermostats.

The remote probe sensor is supplied with 3 meters of cable as standard but can be extended up to a maximum of 20 meters if required. The ability to extend the underfloor heating probe provides a highly flexible solutions should you wish to install the underfloor heating thermostat in a remote location. The probe is covered in a flexible PPC coating ensuring a durable and waterproof finish.

 

 
Electrical Performances
 
NOItemSignTest ConditionsMin.Nor.Max.Unit
1.Resistance at 25℃R25

Ta=25±0.05℃

PT≦0.1mw

14.8515.015.15
2.B ValueB25/50 3435.334703504.7k
3.Dissipation factorσIn still airAbout 2mW/℃
4.Time responseτIn flowing waterAbout 15sec
5.Withstanding Voltage/1500VAC 2SecNo breakdownSec
6.Insulation Resistance 500VDC≧100
7.Operating temp. range//-30/+105
 

 

Features

 

Works with a wide range of different thermostats
Please check the resistance values of your current sensor against the table below for compatibility
Cable has high rigidity, allowing it to be easily passed through existing flexible conduit
Suitable for use in wet areas. IP68 Rated (When installed according to manufacturers instructions)
Rubber thermoplastic protective housing for NTC sensor
Sensor dimensions; 17mm x 5mm 

Works with a wide range of different thermostats. Please check the resistance values of your current sensor against the table (Shown on pictures.)
Cable length can be customized(Extendable upto 20 meters)
Suitable for use in wet areas - IP68 (When installed according to manufacturers instructions)
No polarity, simply connect the two wires either way round to the sensor outlet on the thermostat.

Electric Underfloor Heating Remote Probe Floor Sensor

Used as Air or Floor Sensor

Waterproof

5mm Probe Diameter

 

 

Installation Recommendations

:
When installing the EcoHeatCool underfloor heating remote probe into any form of screed or solid floor construction we recommend you run the thermostat into a sleeve (tube) within the floor should the thermostat need to be replaced at a later date.


To extend the underfloor heating probe use an equivalent gauge electrical cable ( Note: The maximum distance from the thermostat should be no more than 20 meters.)

 

Mark the position of the conduit on the floor. Remove the surrounding heatmat(s) and cut a channel 12mm wide x 8mm deep in the floor to accommodate the conduit. This will maintain the overall finished floor level. Ensure that the floor is clean before installation of heatmat(s)

 

 

SENSOR LOCATION

 

The sensor end should be located in the floor between the heating cables/pipes so it measures the typical floor temperature. The sensor tube should not pass over or under the heating cable.

 

 

SENSOR TUBE

 

All Comfort Heat sensors installed in-slab, in-screed or thin mats are installed in a sensor tube. (12mm plastic tube with capped end) This allows the sensor to be removed if required, without lifting floor tiles.

Under-carpet and under timber systems do not require a sensor tube.

 

Sensor Testing


Using a multi-meter, measure the resistance between the two connection wires in the floor temperature sensor flex, and check against the Thermostat Kit Installation / Operation Guide supplied with the thermostat. Check the resistance before and after installation.

 

Where do the RCD/Timer/Thermostat go on the circuit ?
 
The mat is laid and the cold leads are fed into a junction box. It doesn't matter where you physically fix these items, though you may want them to be hidden in a cupboard. If you have a thermostat that reads air temperature, this will need to be in the appropriate room. However, if it is fitted with a floor sensor then this isn't necessary.
 
 
Wiring Diagram Example:’

 

 

HOW DOES THE FLOOR SENSOR DETECT THE TEMPERATURE FOR ELECTRIC UNDERFLOOR HEATING?

 

The most efficient way of running and controlling Electric Underfloor Heating is by using a controller that has a floor sensor attached that is located in the floor in between the heating cables. The floor sensor should be located inside a hollow conduit pipe that runs down the back of the wall and into the floor construction, this means the sensor can be protected from the screed or adhesive so no damage is caused but also can easily be pulled out and new one fed back if necessary at a later date.

The sensor cable is signal/bell wire and has a probe at the end of the sensor that detects the temperature. By being located next top the heating cable the temperature is more reactive and less influenced by the changes in Ambient temperature meaning the system will constantly adjust itself without the need for being on for extended periods of time.

Although the controller on the wall can be switched to read the Ambient temperature, it is not Touch Underfloor Heatings preferred option as it can be easily influenced by draughts, sunlight, high temperatures etc meaning your Underfloor Heating system will either run constantly or not at all. Tocuh Underfloor Heating provised the 10mm conduit pipe as part of the Kit.

More thermostat help can be found here.

 

 

Reliability Test

 

NOItemTechnical requirementsTest conditions and method
1.Dry heat storage

△R25: R25≤±3%

△B25/85: B25/85≤±2%

80±2℃,Room temperature storage 1000H.
2.Warm storage55±2℃,95% RH, Room temperature storage 1000H.
3.Low temperature storage-30±2℃, Room temperature storage 1000H.
4.Temp. cycle test-20℃×30min → 25℃×10min →100℃ Water×30min → 25℃×10min, total 10 cycles
5Lead wire pulling testNo visible damage, and are within specificationFix the product and apply 9.8Nor 1.0kg force on axial direction of each lead wire, for 10 secs.
6Lead wire bending testFix the product and apply 100g force on axial direction of each lead wire, then bend both lead wires to same direction slowly, before bending them back to original location, for 10 times
7Welding abilityTin covered area should be larger than 90%Soak lead wires with flux, immerse into flux at 230-260, for 3 to 5 secs.

 

 

Resistance Vs. Temperature Table

 

R-T CONVERSION TABLE
R25=15KΩ±1% B25/50=3470K±1%
T/℃RminRcenRmaxT/℃RminRcenRmax
-55765.738804.9845.979-20106.488109.725113.05
-54712.99748.914786.569-19101.264104.29107.395
-53665.938699.009733.648-1896.32999.157102.058
-52623.575654.108686.067-1791.66594.30997.02
-51585.122613.377642.932-1687.25789.72992.262
-50549.967576.164603.548-1583.08985.40187.768
-49517.631541.956567.367-1479.14681.30983.522
-48487.733510.346533.954-1375.41677.43979.508
-47459.969481.01502.963-1271.88673.77875.713
-46434.092453.684474.113-1168.54470.31472.123
-45409.905428.157447.177-1065.37867.03568.726
-44387.243404.254421.969-962.37963.92965.511
-43365.97381.829398.334-859.53660.98762.467
-42345.973360.76376.141-756.84158.19959.583
-41327.154340.943355.279-654.28455.55556.85
-40309.428322.29335.652-551.85953.04854.26
-39292.723304.719317.175-449.55650.6751.804
-38276.973288.163299.774-347.37148.41349.473
-37262.119272.557283.382-245.29446.2747.262
-36248.108257.845267.937-143.32144.23545.163
-35234.891243.974253.383041.31442.16543.029
-34222.422230.896239.668139.66340.46341.276
-33210.659218.565226.744237.96738.71639.476
-32199.562206.938214.565336.35437.05537.765
-31189.093195.975203.088434.81835.47436.138
-30179.217185.64192.273533.35633.96934.591
-29169.901175.894182.081631.96332.53733.118
-28161.112166.706172.477730.63731.17431.716
-27152.821158.043163.427829.37329.87430.382
-26144.998149.873154.897928.16828.63729.111
-25137.618142.17146.8571027.01927.45727.9
-24130.653134.904139.2791125.92326.33226.746
-23124.08128.05132.1341224.87725.2625.646
-22117.876121.584125.3971323.87924.23724.597
-21112.019115.483119.0431422.92723.2623.596
        
R-T CONVERSION TABLE
R25=15KΩ±1% B25/50=3470K±1%
T/℃RminRcenRmaxT/℃RminRcenRmax
1522.01722.32922.642525.5895.75.813
1621.14921.43921.731535.4045.5135.624
1720.31920.5920.861545.2265.3345.443
1819.52619.77820.031555.0555.1615.268
1918.76919.00319.239564.894.9945.1
2018.04418.26318.482574.7324.8344.938
2117.35217.55517.758584.5794.684.782
2216.68916.87817.067594.4324.5314.631
2316.05616.23116.406604.2914.3884.486
2415.44915.61215.774614.1544.2494.346
2514.851515.15624.0234.1164.212
2614.30314.45314.602633.8963.9884.082
2713.76113.9114.06643.7743.8643.956
2813.24213.39113.54653.6563.7453.835
2912.74512.89413.042663.5433.633.718
3012.2712.41712.565673.4333.5193.606
3111.81511.96112.108683.3283.4123.497
3211.37911.52411.67693.2263.3083.392
3310.96111.10511.25703.1283.2083.291
3410.56110.70410.847713.0333.1123.193
3510.17810.31910.461722.9413.0193.098
369.819.9510.091732.8532.9293.007
379.4579.5969.735742.7672.8422.919
389.1199.2569.394752.6852.7592.834
398.7958.939.066762.6052.6782.751
408.4848.6188.752772.5292.5992.672
418.1868.3178.45782.4542.5242.595
427.8998.0298.16792.3832.4512.52
437.6247.7527.882802.3132.382.448
447.367.4867.614812.2462.3122.379
457.1077.2317.357822.1812.2462.312
466.8636.9867.11832.1192.1822.247
476.6296.756.872842.0582.122.184
486.4046.5236.6438522.0612.123
496.1886.3056.424861.9432.0032.064
505.986.0966.212871.8881.9472.007
515.7815.8946.009881.8361.8931.952
R-T CONVERSION TABLE
R25=15KΩ±1% B25/50=3470K±1%
T/℃RminRcenRmaxT/℃RminRcenRmax
881.8361.8931.9521110.9971.0351.073
891.7841.8411.8981120.9731.011.048
901.7351.791.8471130.950.9861.024
911.6871.7411.7971140.9280.9631
921.6411.6941.7481150.9060.9410.977
931.5961.6481.7021160.8850.9190.955
941.5521.6041.6561170.8650.8990.934
951.5111.5611.6121180.8450.8790.913
961.471.5191.571190.8270.8590.893
971.4311.4791.5291200.8080.840.874
981.3931.441.4891210.7910.8220.855
991.3561.4021.451220.7740.8050.837
1001.321.3661.4131230.7570.7880.819
1011.2861.3311.3771240.7410.7710.802
1021.2531.2971.3421250.7260.7560.786
1031.221.2641.308    
1041.1891.2321.275    
1051.1591.2011.244    
1061.131.1711.213    
1071.1011.1421.183    
1081.0741.1141.154    
1091.0481.0861.126    
1101.0221.061.099    
        

 

 

Ordering Information

 

Part NumberDescription@25MOQ
CWFM0153FB1-202M113XPVC Overmolded Cap Φ5.3*17mm Length 2 meterS15K Ω1000
CWFM0153FB1-322M113XPVC Overmolded Cap Φ5.3*17mm Length 3.2 meterS15K Ω1000
CWFM0153FB1-502M113XPVC Overmolded Cap Φ5.3*17mm Length 5 meterS15K Ω1000

 

* For quantities less than Minimum Order Quantity - contact us.

Hot Products

Alumlnum 4" 8W 600LM LED Slim Recessed Round Down Light / Surge Protection 3000V Product name LED ...
4" 10W 700LM J-Box Round LED Recessed Down Light Waterproof Class IP20 Advantages of our LED Down ...
Beam Angle 100° 6" 12W 840LM 5CCT LED Slim Recessed Round Down Light Application 1. Workshop, ...
Producing Low Heat 6" 15W 1125LM LED Recessed Round Retrofit Down Light Product parameters Brand ...
Aluminium 4" 12W 1000LM LED Recessed Round Retrofit Down Light High Luminous Efficiency Product ...
Alumlnum 6" 12W 1000LM LED Round Panel LED Recessed Round Retrofit Down Light Disk Light 1. UL ES ...