Home Companies Xi'an Kacise Optronics Co.,Ltd.

KUS3000 M18 Compact Housing Ultrasonic Proximity Sensor High Repeatability

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

KUS3000 M18 Compact Housing Ultrasonic Proximity Sensor High Repeatability

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

KUS3000 M18 Ultrasonic Level Meter

1. Dimensional structure
The unit is mm.

      M18 series size structure
 

2. Electrical interface

 

 

Note: This product has two cable specifications, and the cable wiring instructions of the two specifications are as follows:

Type A cableType B cable
Pin1BrownPin1Yellow
Pin2WhitePin2Black
Pin3BluePin3Red
Pin4BlackPin4Green

The default cable mix is based on the specifications received by the customer

 

3. Technical parameter

M18
range150... 1000 mm
Adjustable interval range150….1000mm
blind spot0 ... 150 mm
Response timeapprox. 10 ms

 

Indicator light

Blue led lightThe blue light flashes to indicate that calibration can be performed. Blue and other constants indicate that the power supply of the sensor is normal. The blue light will flash within 5 minutes after the power is turned on, indicating that the user can perform output adjustment and calibration. After 5 minutes, the blue light is always on to indicate that the sensor cannot be receiving Calibration command. .
Tellow led lightIt is used to indicate whether the measured object is detected. During the calibration stage, the yellow light flashes to indicate that the current calibration state is locked, and it can be switched to the next calibration state.
Red LED light

In normal working state, the red light is not on, and the red light is on to indicate that there is a fault.

During the calibration process, the flashing red light indicates that the sensor locks the current echo loss or infinity state, and the user can switch to the next calibration state.

 

Electrical parameters

Supply voltage13 ... 30 V DC , Special wide voltage requirements can be customized
No-load current I0≤ 45 mA

 

IOT-spectric models

Supply voltage3.3-12 DC , ripple 10 %SS
Power consumption I0≤ 15 mA, sleep mode≤1mA, Serial wake up,

 

Output

output type

1 Switch output PNP output normally open and long closed can be calibrated

2 Switch output NPN output normally open and long closed programmable

3 Analog voltage output 0-10V programmable.

4 Analog 4-20mA output programmable

5 RS485 output E4 programmable.

Overcurrent Ie200 mA , Reverse polarity protection, short circuit protection
Default setting

M18 Switch point A1: 150mm Switch point A2: 1000mm

M30 Type 1 switch point A1 200mm switch point A2: 2000mm

M30 type 2 switch point A1 300mm switch point A2: 4000mm

M30 type 3 switch point A1 500mm switch point A2: 6000mm

Output voltage drop≤ 2.5 V
Repeatability≤1 %
On-off level f≤ 13 Hz High frequency can be customized
Default hysteresis characteristic amplitude5% of the set value, special requirements can be customized
Temperature Compensation Range-40℃-85℃

 

Temperature Requirements

Working temperature-25…70℃(248...343K)
Storage temperature-40…85℃(233...358K)

 

Mechanical part description

ConnectionV1 connector(M12×1),4-Pin
Protection classIP65 Other can be customized
Shell materialNickel-plated copper, others can be customized

 

Note: When the M18 product and M30 product have 4-20mA analog output, the meter connection method is different from that of the 550,600 product. Since the output terminal of the M18 and M30 products is powered by VDD, as shown in Figure 1, the meter should be connected to the power supply port. Between the output terminal and the output terminal, the connection instruction diagram is shown in Figure 2:

Figure 1 Output power supply circuit diagram

Figure 2 Schematic diagram of connection method

 

4. Order information

KUSTypes ofoutputrangedescribe
 M18M18 housing, maximum measuring range is 1 meter
M30-Type1M30 maximum measuring range is 2 meter
M30-Type2M30 maximum measuring range is 3 meter
M30-Type3M30 maximum measuring range is 6 meter, 8 meters can be customized
CustomizedShell supports user customization
 NPNoutput as NPN
PNPoutput as PNP
10VoutThe output is analog 0-10V, the power supply requirement is greater than 11V
5VoutThe output is analog 0-5V, the power supply requirement is greater than 6V
mAoutThe output is analog 4-20mA
RS485The output is RS485 Modbus protocol, please refer to the software interface manual for specific description.
  XXX mmThe customer specifies the linear interval or switch interval, which can be set at the factory
KUSM30RS4852000mm 

 

5.Application

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...