100% Vol Ir CO2 Gas Detector Sensor Module Heteronuclear Molecules

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

 

KCS571

Infrared CO2 Gas Sensor Module

 

 

 

 

 

1. Brief Introduction

SW711 is a gas sensor based on the principle of NDIR infrared absorption, suitable for testing the gas concentration of various heteronuclear molecules in industrial applications.

SW711 adopts a patented optical cavity, imported light source and dual-channel detector to achieve dual optical path reference compensation in space. SW711 has good selectivity, no oxygen dependence and long life.

The SW711 has UART, 4 to 20mA outputs, 485 outputs, etc., and provides customers with a manually calibrated MCDL pin. It is convenient for customers to use outdoor free-flowing clean air to calibrate the sensor module relative to zero.

SW711 adopts diffusion ventilation method, and the response time is less than 30 seconds.

The SW711 is available in a variety of packages that can be customized to meet customer needs. There are three common packages: package one, package two (six pins 4-20mA), package three (seven pins 485 interface), of which package two and package three are the same size.

 

 

 

 

 

2. KCS571 size block diagram

 

 

 

Package one

 

 

Package 2 (6-pin 4-20mA) Package 3 (7-pin 4 85 connectors).

 

 

3. KCS571 Technical Parameters

 

 

parametersymbolminimumTypical valuesmaximumunit
Storage TemperatureTstg-20-80°C
Operating TemperatureTA-20 60°C
Operating HumidityHA0 90% RH
Work PressurePA0.8 1.2atm
Supply VoltageVs555.5V
Maximum Operating CurrentImax 120150mA
Detection Range20050000100% vol can be customized ppm
Measurement accuracy-± 50ppm or ±3% true value± 300ppm± 3% true ppm
T90diffusion-3060second
repeatabilityzero  <±50 ppm
50% FS- <±2% of the measured value- 
life span 3510year

 

 

 

 

5.Installation instructions

The sensor mounting thread dimensions refer to the block diagram.

6.Matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, it is recommended that it be no more than 3 months, and calibration is not required on the long-term operation side if automatic calibration is turned on

Do not use the sensor for a long time in an environment with a high density of dust

Please use the sensor within the range of the sensor's power supply

7.Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information

1) Sensor name, 2) Sensor range 3) Sensor measurement accuracy and output mode, etc

For example, SW711, 50000ppm, 4-20mA output

 

 

 

 

 

8.Ordering Information

 

Order Information Selection Form
productspower supplyCable lengthSignal output  
KCS571Infrared CO2 Gas Sensor Module 
 12VDCPower supply is 12VDC (default) 
220V/110VACThe power supply is 220/110VAC 
 Cable length  
XXmThe default is 5 meters, the maximum is 500 meters 
 4-20mA4-20mA output without RS485 output 
RS485RS485 output, without 4-20mA output by default 
ARS4854-20mA output with RS485 output 
 Modbus-RTUThe protocol for the RS485 output is Analog-to-Digital Bus-RTU (default) 
Modbus-ASCThe protocol for RS485 output is Modbus-RTU 
KCS571DC12V5 metersRS485  
        

 

9.Precautions

 

 

1 In environments with EMC issues, shielded cables must be used.

2 When the module is cold started, the warm-up time should not be less than 2 minutes.

3 The sensor should be calibrated regularly, not more than 3 months is recommended.

4 Do not use the sensor for a long time in a dusty environment.

5 Please pay attention to the wiring of the positive and negative terminals of the power supply and the signal output terminals. Do not connect backwards.

6 High concentrations of chemical contamination can lead to the destruction of the sensor polymer layer, therefore, the product should be stored and used away from the source of chemical contamination.

7 Please refer to the relevant national product installation standards for the installation process.

 

 

Contact Details

URL: www.kacise.com

Tel: +86-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, High-tech Zone, Xi'an, Shaanxi Province

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix

 

ShorthandFull name
VOL1% VOL refers to 1% of the volume of a particular gas in air.
PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2Oxygen molecules
LCDLCD display
RS485Asynchronous serial port 485
DCdirect current
ACCommunication
PVCpolyvinyl chloride

 

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...