Electromagnetic flowmeter is suitable for liquid flow measurement with uniform and conductive texture

Introduction

Insertion Electromagnetic Flowmeter is a kind of induction instrument designed by Faraday’s law of electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of insertion of single chip to realize digital excitation and employs CAN local fieldbus.

Insertion Electromagnetic Flowmeter can realize local indication and output electrical current signal of 4-20mA which can be used to record, adjust and control. Insertion electromagnetic flowmeter is used to measure the flow of conductive fluid in water, iron and steel, petroleum, chemical, electric power, industry, water conservancy, etc. it can also be used to measure acid, alkali, salt and other corrosive conductive liquids.

 

Features

1. Simple structures, firm, no movable parts and long operation life.

2. No intercepting fluid parts, no pressure loss and fluid clogging.

3. No mechanical inertia, quick response and good stability, application in automatic examination, adjustment & controlling.

4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.

5. Employ Teflon or rubber liner and different combination of electrode material such as Hastelloy C, Hastelloy B, 316L, and Titanium and adapt the need of different mediums.

6. Supply many styles of flow meters such as inline type and insertion type, etc. Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.

7. Integral type electromagnetic flow meters and remote type electromagnetic flow meters.

8. LCD back light display with high clearness. (Option: LED display is optional).

 

Specifications

ItemsDescription
Suitable DiameterDN200~DN2600
Suitable FluidLiquid with conductive ratio more than 5 μs/cm
Measuring Range0.5~10m/s (extendable to 15m/s)
Upper Limit of Span0.5~10m/s. 1~5m/s recommended
Accuracy0.3% (Option), 0.5%, 1.0% of F.S..
RepeatabilityBelow 0.25%
Display of Converter

Display : Flow rate ( 4-digits), Totalizer (9-digits), Velocity, Alarm status

by LCD ( LED-option)

Scale unit: selectable of L/h, L/m, L/s, m3/h, m3/m, m3/s
Flow direction : selectable by program
3 Digits display below of decimal points.
K-factor: 5 digits.
Data logger for 2-3years.
Programming language: English, Korean(on request)
Mounting: Integral type; Remote Type
PowerAC: 220V, 50-60Hz; DC: +24V(Option)
Output Signals

4~20m ADC, load ≤ 750ohm,

0~3kHz, 5V with source and changeable width.

High terminal and effective frequency output

Voltage output:0-5 V DC

Conduit connectionM20 * 1.5 Thread
Communication InterfaceRS-232; RS-485; HART
Operation Pressure1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
Fluid Temperature-20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material
Ambient TemperatureSensor -40°C ~80°C. transducer -15°C ~50°C
Ambient Humidity≤ 85%RH (at 20C)
Cable Outlet SizeM20×1.5
Power Supply220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years)
Power Consumption≤ 8W
Protection RatingsIntegral type: IP65. Remote type: sensor IP68, transducer IP65.
MaterialsElectrode

316L (stainless steel), Hastelloy C, Hastelloy B,

Titanium, Tantalum, etc.

 LinerPTFE, Soft rubber, Hard rubber, F46, FS, PUR.
Measuring tubeSUS 304
FlangeCarbone Steal
Ground ring316L (stainless steel), HC, Ti, Ta, Cu.
Connection of Flange

National Standard GB9119-88 (DIN2051, BS4504), JIS, ANSI. Screw.

Tri-clamp for sanitary application

Insertion type.

EX-proof protectionExde ib ii BT2
Quality controlISO9001-2008, CE

 

Ordering Information

 

 

 

Our Services

 

  • Your inquiry will be replied in 24hours.
  • Well-trained and experienced staffs to answer all your enquires in fluent English.
  • OEM&ODM, we can help you to design and your request will be put into product.
  • Distributorship are offered for your unique design and some our current models.
  • Protection of your sales area, ideas of design and all your private information.
  • Discounts are offered based on order quantities.

 

We supply high quality Insertion Electromagnetic Flowmeter, hope we can coopperate in near future by providing you suitable products, good services and reasonable prices.

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...