KUS3000 M30-Type1 Ultrasonic Level Meter


 

1. Dimensional structure

The unit is mm.

2. Electrical interface

Note: This product has two cable specifications, and the cable wiring instructions of the two specifications are as follows:

Type A cableType B cable
Pin1BrownPin1Yellow
Pin2WhitePin2Black
Pin3BluePin3Red
Pin4BlackPin4Green

 

The default cable mix is based on the specifications received by the customer

3. Technical parameter

M30-type 1
Range200... 2000 mm
Adjustable interval range200….2000mm
Blind spot0 ... 200 mm
Response timeapprox. 10 ms


Indicator light

Blue led lightThe blue light flashes to indicate that calibration can be performed. Blue and other constants indicate that the power supply of the sensor is normal. The blue light will flash within 5 minutes after the power is turned on, indicating that the user can perform output adjustment and calibration. After 5 minutes, the blue light is always on to indicate that the sensor cannot be receiving Calibration command. .
Tellow led lightIt is used to indicate whether the measured object is detected. During the calibration stage, the yellow light flashes to indicate that the current calibration state is locked, and it can be switched to the next calibration state.
Red LED light

In normal working state, the red light is not on, and the red light is on to indicate that there is a fault.

During the calibration process, the flashing red light indicates that the sensor locks the current echo loss or infinity state, and the user can switch to the next calibration state.

 

Electrical parameters

Supply voltage13 ... 30 V DC , Special wide voltage requirements can be customized
No-load current I0≤ 45 mA

 

IOT-spectric models

Supply voltage3.3-12 DC , ripple 10 %SS
Power consumption I0≤ 15 mA, sleep mode≤1mA, Serial wake up,

 

Output

Output type

1 Switch output PNP output normally open and long closed can be calibrated

2 Switch output NPN output normally open and long closed programmable

3 Analog voltage output 0-10V programmable.

4 Analog 4-20mA output programmable

5 RS485 output E4 programmable.

Overcurrent Ie200 mA , Reverse polarity protection, short circuit protection
Default setting

M18 Switch point A1: 150mm Switch point A2: 1000mm

M30 Type 1 switch point A1 200mm switch point A2: 2000mm

M30 type 2 switch point A1 300mm switch point A2: 4000mm

M30 type 3 switch point A1 500mm switch point A2: 6000mm

Output voltage drop≤ 2.5 V
Repeatability≤1 %
On-off level f≤ 13 Hz High frequency can be customized
Default hysteresis characteristic amplitude5% of the set value, special requirements can be customized
Temperature Compensation Range-40℃-85℃

 

Temperature Requirements

Working temperature-25…70℃(248...343K)
Storage temperature-40…85℃(233...358K)

 

Mechanical part description

Even machineV1 connector(M12×1),4-Pin
Protection classIP65 Other can be customized
Shell materialNickel-plated copper, others can be customized

Note: When the M18 product and M30 product have 4-20mA analog output, the meter connection method is different from that of the 550,600 product. Since the output terminal of the M18 and M30 products is powered by VDD, as shown in Figure 1, the meter should be connected to the power supply port. Between the output terminal and the output terminal, the connection instruction diagram is shown in Figure 2:


        Figure 1 Output power supply circuit diagram

 

 

 


 

Figure 2 Schematic diagram of connection method

 

4. Sensor function description

Switch point and advance interval setting and adjustment of switch output and analog output products

Switch value and analog output can be set using the adjustment terminal, specifically, there are 8 working modes that can be set.

The specific setting method of each type of bean flour is the following steps.

In the first step, the user selects a distance set by himself, or puts the sensor into a lost wave state.

The second part, connect the calibration terminal to the power supply or GND, keep it connected until the yellow light flashes (if the wave is lost, the red light flashes).

In the third step, the user selects the second distance set by himself, or lets the sensor enter the lost wave state.

The fourth step, connect the calibration terminal to GND or power supply (the state is different from the second step), keep it connected until the yellow light flashes (if the wave is lost, the red light flashes).

There are 8 working modes of switch output

1. Window normally open mode (analog output products are in positive linear working mode or distance measurement mode).

2. Window normally closed mode (analog output product is in negative linear working mode or liquid level measurement mode).

3. Single point normally open mode.

4. Single point normally closed mode.

5. Single-point normally open mode with large hysteresis interval.

6. Single point normally closed with large hysteresis interval mode.

7. Whether to detect the normally open mode.

8. Whether to detect normally closed mode.

Description of RS485 output model products.

There are 3 working modes,

1: Automatic measurement mode, the sensor continuously measures the liquid level and distance, and the user can read the measurement results through the 485 interface at any time.

2: If the user does not initiate a 485 communication, the sensor will initiate a measurement and report the result.

3: Sleep mode, the product enters sleep mode, the user first wakes up the sensor through the 485 interface, and then initiates a measurement and obtains the result before the sensor sleeps again.

Definition of LED indicator meaning
  When calibratingDuring normal work
red lightBrighterror indicationerror indication
extinguishnormal worknormal work
flickerIndicates the status of the calibration station lock-on echo lossmeaningless
Yellow lightBright----detected object
extinguish------The measured object is lost
flickerInstructs the calibration stage to lock the current position and can switch to the next calibration stateThe echo lost and echo detected states alternate. relatively critical.
Blue lightBrightnormal power supplynormal power supply
extinguishAbnormal power supplyAbnormal power supply
flickerIndicates that the user can calibrate the sensor at the current timemeaningless

 

5. Installation conditions

When installing, pay attention to protect the surface of the sensor to avoid injury. If you work in an environment with heavy volatile gas or dust and heavy condensation, you need to clean the surface of the sensor regularly to avoid sensitivity reduction or failure to work. The installation thread should not be over-tightened, which will cause the sensor to be pressurized and not work properly.

6. Order information

KUS

 

Types ofOutputRangeDescribe
 M18M18 housing, maximum measuring range is 1 meter
M30-Type1M30 maximum measuring range is 2 meter
M30-Type2M30 maximum measuring range is 3 meter
M30-Type3M30 maximum measuring range is 6 meter, 8 meters can be customized
CustomizedShell supports user customization
 NPNoutput as NPN
PNPoutput as PNP
10VoutThe output is analog 0-10V, the power supply requirement is greater than 11V
5VoutThe output is analog 0-5V, the power supply requirement is greater than 6V
mAoutThe output is analog 4-20mA
RS485The output is RS485 Modbus protocol, please refer to the software interface manual for specific description.
  XXX mmThe customer specifies the linear interval or switch interval, which can be set at the factory
KUSM30RS4852000mm 

 

 

 

 


 

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...