KUS600 series ultrasonic transmitter

1. Dimensions

Unit in the diagram is mm.

 


2. Electronic interface and signals definition

 

Cable colorPinDescriptionNote
Red1Power supply 
Black2GND 
Yellow3Analogue outputThe 600B will work in mode 1 or 0 cannot work in power save mode, if the 4-20mA, 0-3.3V 0-5V analogue output used.
Blue4RS485A+TTL-TXD for ttl output signal
Green5RS485B-TTL-RXD for ttl output signal
 

For switch output

Cable colorPinDescriptionNote
Red1Power supply 
Black2GND 
Yellow3Switch outputLoad current 1A@60V
White4Switch output
Brown5RS485A+TTL-TXD for ttl output signal
Green6RS485B-TTL-RXD for ttl output signal
 

 

3. Parameter

General specifications

600B

 

Sensing range600... 5000 mm@3.3V power supply. The measure distance can reach 6 meters if the power supply is 24V.
Adjustment range300….5000mm
Unusable area0 ... 600 mm
Response delayapprox. 10 ms

 

Electrical specifications

 

Operating voltage UB3.3 ... 24 V DC , ripple 10 %SS
No-load supply current I0≤ 20 mA active period and ≤0.3mA during sleep time

4. Description of Sensor Functions

The detail refers to the 600B software engineer application guide.

Adjusting the analogue output.

The analogue output can be programed as the user want. Such as working at switch output or working at liner output all the parameters can be set by the RS485 interface.

There is 8 types of output functions can be programed.

All the setting routine as follows,

step 1 set one pointed distance by the RS485,

step 2 set another pointed distance by the RS485.

Step3 set the output type liner or switch, and set the related output options

Step4 reboot the sensor.

1. Window mode normally-open and liner mode positive slope output function.

2. Window mode normally-closed and liner mode negative slope output function.

3. Single switching point, normally-open function.

4. Single switching point, normally-closed function.

5. Single switch point with hysteresis gap normally-open function.

6. Single switch point with hysteresis gap normally-closed function.

7. Detection of object presence-normal open function.

8. Detection of object presence-closed open function.

Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only setting the request distance after power restart.

For the RS485 output type.

There are 2 kinds of working style,

One for auto measure, the sensor will measure the distance or level repeatedly, and the measurement period can be set by the UART. The measure result can be fetched every time.

The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU.

For example the measure result can be read by access the register 0x101 by Modbus protocol.

For more information please contact us for the software engineering guide.

5. Installation conditions

If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.

6. Ordering information

KUSBody sizeOUTPUTMax rangeDescription
 600 
CustomizedCustomized
 SWSwitch Output (online configurable for NPN or PNP)
mA3 wire 4-20mA output
10VOutput is Vout 0-10V
5VOutput is Vout 0-5V The power supply range is 5.0 at least
3.3VOutput is Vout 0-3.3V The power supply range is 3.3 at least
RS485Output is RS485
TTLUART TTL output
 XXX mmXxx mm is the maxim range can be detected, the default length is 1 meter
KUS600RS4855000mm 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Products

1. Description KPS110 pressure and temperature integrated transmitter is a temperature and pressure ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Features 1) ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...
Kacise IP66 High Accuracy Wide Pressure Range Digital Pressure Gauge With Data Logger 1. Overview ...