Home Companies Xi'an Kacise Optronics Co.,Ltd.

MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

MF30 Series Ultrasonic Distance Sensor 200mm - 6000mm Detection Range with NPN PNP Anolog Output

1. Parameter

General specifications

M18
Sensing range100... 1000 mm
Adjustment range100….1000mm
Unusable area0 ... 100 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox.220 kHz
Response delayapprox. 10 ms

 

 

M30-type1
Sensing range200... 2000 mm
Adjustment range200….2000mm
Unusable area0 ... 200 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox.150 kHz
Response delayapprox. 10 ms

 

 

M30-type2
Sensing range200... 3000 mm
Adjustment range200….3000mm
Unusable area0 ... 150 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox.70 kHz
Response delayapprox. 20 ms

 

 

M30-type3
Sensing range400... 6000 mm
Adjustment range400….6000mm
Unusable area0 ... 300 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox.50 kHz
Response delayapprox. 40 ms

 

Indicators/operating means

 

LED blue

Flashing :program can be acted, this status

The Blue led will flash around 5 minute after the sensor power on, indicate the sensor can be programed, and then the blue led will perpetually turn on. To indicate the power status.

LED yellow

indication of the switching state

flashing: during program function object detected

LED red

Normal working: light on indicate error detected.

Programing: flashing, echo lost, that means the sensor covered or no object in the fromt of the sensor,

Electrical specifications

 

Operating voltage UB13 ... 30 V DC , ripple 10 %SS
No-load supply current I0≤ 45 mA

Input

Input type1 TEACH-IN input

operating range A1: 0V/GND ... +1 V, operating range A2: +6 V ...

+UB

input impedance: > 4.7 kΩ ; TEACH-IN program pulse: ≥ 1 s

 

Output

 

Output type

1 switch output E4, NPN NO/NC, programmable

2 switch output E4, PNP NO/NC, programmable

3 Analog 0-10V output E4 programmable.

4 Analog 4-20mA output E4 programmable

5 RS485 output E4 programmable.

Rated operating current Ie200 mA , short-circuit/overload protected
Default settingSwitching point A1:150mm Switching point A2: 1000mm
Voltage drop≤ 2.5 V
Repeat accuracy≤1 %
Switching frequency f≤ 13 Hz(customized for high frequency version)
Range hysteresis H5 % of the set operating distance
Temperature influence±1.5% of full-scale value

Ambient conditions

 

Ambient temperature-25…70℃(248...343K)
Storage temperature-40…85℃(233...358K)

Mechanical specifications

 

ConnectionV1 connector(M12×1),4-pin
Protection degreeIP67
Material Housingbrass, nickel-plated
Transducer

epoxy resin/hollow glass sphere mixture;

foam polyurethane, cover PBT

 

2. Dimensions

3. Electronic interface and signals definition

4. Description of Sensor Functions

Adjusting the switching points and the analog output.

The switch output type and analog output type sensor can be programed as the user want.

There is 8 types of output functions can be programed.

All the teach routine as follows,

step 1 teach one point with the related teach in condition(High level voltage or GND). step 2 choose a different distance(not the same with step1) point and a different teach in condition(not same with the step1). The program routine must be finished during the blue led flashing, the default value will be efficient if the not.

The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure. Switching point A1 is taught with - UB, A2 with +UB. Five different output functions can be set.

1. Window mode normally-open and liner mode positive slope output function.

2. Window mode normally-closed and liner mode negative slope output function.

3. Single switching point, normally-open function.

4. Single switching point, normally-closed function.

5. Single switch point with hysteresis gap normally-open function.

6. Single switch point with hysteresis gap normally-closed function.

7. Detection of object presence-normal open function.

8. Detection of object presence-closed open function.

Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only setting the request distance after power restart.

For the RS485 output type.

There is 2 kinds of working style,

One for auto measure, the sensor will measure the distance or level repeatedly, and the measurement period can be set by the uart. The measure result can be fetched every time.

The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU.

For example the measure result can be read by access the register 0x101 by Modbus protocol.

For more information please contact us for the software engineering guide.

 

LED displays
  Programming timeWorking time
Red LEDON--Error accured
OFFWorking wellWorking well
Flash

Doing the echo lost program,

For Single switching point, program, or Detection of object.

-----
Yellow LEDON----Object detacted
OFF------Echo lost
Flash

Teach in for the status ready,

That means the sensor has locked the set distance for program

-----
Blue LEDONPower onPower on
OFFPower offPower off
Flash

Program period indication,

Only the blue led flashes the program routine can be done

Program can be carried on

 

 

Hot Products

GXPS 4-20ma differential pressure transmitter GXPS500 4-20ma differential pressure transmitter 1. ...
GXPS353 Universal Pressure Transmitter / Industry High Accuracy Pressure Sensor Feature Accuracy: ±0...
GXPS600 Series ±0.5%F.S Accuracy Digital RS485 Digital output pressure sensor Pressure Transducer ...
KSCCP21 Capacitive Ceramic High Accuracy Pressure Sensor Compact Design Long Term Stability pressure ...
GXPS353 Analog signal output 4-20mA Output Pressure Sensor for Automatic Detection System Applicatio...
Hirschman connector water pipe pressure sensor water tank pressure transmitter MEMS diaphragm 4-20mA ...