High quality low price battery powered water sewage flow meter electromagnetic flowmeter 

Description

 

GXEFM2000 electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.

There are two basic components of electromagnetic flow meter:

1) The Detector,which includes the flow tube, isolating liner and measuring electrodes

2) The Converter, which is the electronic device responsible for signal processing, flow calculation, display and output signals.

The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of service. Revise of the compatibilities consistent with the shipment of each meter.

 

Parameters

 

Pipe diameterDN6~DN2600
Accuracy0.3% (Option), 0.5%, 1.0% of F.S..
RepeatabilityBelow 0.25%
PowerAC: 220V, 50-60Hz; DC: +24V(Option)
Output Signals4~20mA, Pulse, 0~5V
Conduit connectionM20 * 1.5 Thread
Communication InterfaceRS-232; RS-485; HART
Operation Pressure1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
Fluid Temperature-20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material
Ambient TemperatureSensor -40°C ~80°C. transducer -15°C ~50°C
Ambient Humidity≤ 85%RH (at 20C)
Cable Outlet SizeM20×1.5
Power Supply220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years)
Power Consumption≤ 15W
Protection RatingsRemote type: sensor IP68, transducer IP65.
MaterialsElectrode316L (stainless steel), Hastelloy C, Hastelloy B,Titanium, Tantalum, etc.
 LinerPTFE, Soft rubb er, Hard rubber, F46, FS, PUR.
Measuring tubeSS 304, carbon steel
FlangeCarbon Steal, SS304
Ground ring316L (stainless steel), HC, Ti, Ta, Cu.
Connection of Flange

National Standard GB9119-88 (DIN2051, BS4504), JIS,ANSI. Screw.

Tri-clamp for sanitary application

Insertion type.

EX-proof protectionExde ib ii BT2
Quality control

ISO9001-2008, CE                                                                                       

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ordering information

 

Model Suffix Code Description
GXEFM3000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter-Com        Compact type
-Rem        Remote type
-Bat        Battery power supply type
-PRO        process control type
Signal Outpt-N       No output
-4mA       4-20mA
-Pul       1~5KHz pulse
-4Pul       4~20mA / 1~5KHz
Communication-N      No communication
-Hart      HART
-MOD      MODBUS-RTU
-PRO      PROFIBUS
-GPRS      GPRS net
-CDMA      CDMA net
-WHRT      Wireless HART
-Other      special order
Power Supply-AC     85V~250Vac@46~63Hz
nominal 20W
-DC     20~36VDC nominal 20W
-Bat     Battery power supply
-Bat+     Battery +12Vdc dual power supply
Other     special request
Electorde Material-316L    Stainless steel 316L
-HasB    Hastelloy B
-HasC    Hastelloy C276
-Pt    Platinum
-Ta    Tantalum
-Ti    Titanium
-WC    wolfram carbide
Liner material-Rub1   Neoprene(-20-60℃)
-Rub2   Neoprene(-20-90℃)
-Tef1   polytetrafluroethylene(-30-120℃)
-Tef2   polytetrafluroethylene(-20-160℃)
-P   Polyurethane
-FVMQ   FVMQ
-PFA   DFA
-ETFE   Ethylene tetraflurorethylene
Grounding Ring-N  No grounding ring
-GR  Grounding ring
-GE  Grounding Electrode
Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
-Ndon't need

 

 

 

Hot Products

GXPS 4-20ma differential pressure transmitter GXPS500 4-20ma differential pressure transmitter 1. ...
GXPS353 Universal Pressure Transmitter / Industry High Accuracy Pressure Sensor Feature Accuracy: ±0...
GXPS600 Series ±0.5%F.S Accuracy Digital RS485 Digital output pressure sensor Pressure Transducer ...
KSCCP21 Capacitive Ceramic High Accuracy Pressure Sensor Compact Design Long Term Stability pressure ...
GXPS353 Analog signal output 4-20mA Output Pressure Sensor for Automatic Detection System Applicatio...
Hirschman connector water pipe pressure sensor water tank pressure transmitter MEMS diaphragm 4-20mA ...