KLD805 Liquid Wired Radar Type Level Sensor For Continuous Level Measurement

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

KLD805 80G FM Radar Level Sensor

Introduction

KLD805 radar level sensor is very suitable for non-contact level measurement in simple applications with high protection requirements. Typical applications are water treatment, pump station, rainwater overflow tank, open channel flow measurement and water level monitoring.

Feature

  • Exact measurement results independent of medium, process and environmental conditions
  • Maintenance-free operation due to non-contact 80 GHz radar technology
  • High accuracy and reliability
 

KLD805

Medium: strong corrosive liquid, steam, foam,

high temperature. and high pressure

Measuring range: 0.1m~10/20/30/60/100m

Process connection: flange ≥ DN80

Process temperature: -40~200℃

Process pressure: -0.1~2.5MPa

Antenna size: 76mm lens antenna (according to flange size)

Antenna material: PTFE/overall filling

Accuracy: ±1mm

Protection class: IP67

Center frequency: 80GHz

Launch angle: 3°

Power supply: two-wire /DC24V

four-wire /DC12~24V

four-wire /AC220V

Casing: aluminum / plastic / stainless steel

Signal output: two-wire /4...20mA/HART protocol

four-wire 4...20mA/ RS485 Modbus

 

Installation

1.Flange Installation
When using flange installation, the minimum distance between the instrument and the tank wall should be 200mm.
① datum plane
② vessel center or axis of symmetry
  
 
2.Hoisting Installation
    
 

Installation Requirements

 

When installing the instrument, avoid installing it above the material inlet, and try to avoid various objects that affect the signal, such as stirring paddles, etc.


           

 

Under extremely complex working conditions, the instrument can work normally if there is no obstacle in the area with a radius of 20cm centered on the installation point.

 

Installation connection diagram:

The maximum installation spool height H max depends on the installation spool diameter D and the size of the product launch angle.

Too long installation connection will affect the radar performance.

 

 

Dimensions

Casing Dimension
Unit in mm:

 

Production:

 

 

 

 

 

 

 

 

Hot Products

30mm /1.2" aluminium glycerine freon hydraulic pressure gauge Product Description Application PGV ...
60mm /2.5" aluminium glycerine freon nitrogen pressure gauge Product Description Application PGV ...
50mm / 2" brass silicone oil filled refrigerant freon pressure gauge Product Description Application ...
60mm /2.5" brass silicone oil filled lpg ammonia pressure gauge Product Description Application PGV ...
50mm / 2" 316ss oil filled ammonia refrigerant pressure gauge Product Description Application PGV ...
China supplier high accuracy low price digital peak pressure gauge for pressure peak value recording ...