Home Companies Xi'an Kacise Optronics Co.,Ltd.

1.6MPa Pressure GPRS Water Meter , Wirless Water Meter With Pulse Output

Xi'an Kacise Optronics Co.,Ltd.

Contact Us

[China] country

Trade Verify

Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.

Contact name:Evelyn Wang

Inquir Now

Xi'an Kacise Optronics Co.,Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

1.6MPa Pressure GPRS Water Meter , Wirless Water Meter With Pulse Output

Country/Region china
City & Province Shaanxi
InquireNow

Product Details

Wirless GPRS Water Meter Pulse Output Water Meter With GPRS Module

 

 

Description

 

Ultrasonic water meter is a new type of water meter which can detect the time difference caused by the change of speed when ultrasonic beam propagates in the water downstream and countercurrent, and analyze and deal with the flow rate of water so as to further calculate the discharge of water.

KACISE KUHM2100 series ultrasonic water meter adopts the most advanced non-magnetic technology, which has the advantages of high precision, stable operation, easy maintenance, strong corrosion resistance, long service life, beautiful appearance, safety and affordable.

Can be widely used in industrial process measurement and control, instead of mechanical flowmeter to improve the accuracy and reliability of measurement, instead of all kinds of high performance flowmeter.

A variety of communication methods can be selected according to the needs of users.

 

Features

 

☆ Measure Heat.
☆ Cold measure and display (for heat/cold Ultrasonic Heat Meter )

☆ Show supply/return water temperature and differential temperature.
☆ Display pile flow measure and instantaneous flow measure.
☆ Running time display.

 

Specifications

 

Installation precautions

 

The ultrasonic water meter can be installed on the inflow pipe or the return pipe. It is installed on the inflow pipe by default. If it is needed on the return pipe, it must be explained in advance. When installing, attention should be paid to whether the arrow on the water meter is consistent with the direction of the medium flow.

 

Note: Whether the ultrasonic meter is installed in the inflow pipe or the return pipe, the sensor should be properly connected (red label for inflow pipe, blue label for return pipe).

Instrument Common Problem

 

The meter cannot work normally

Heating system is working or not;

Globe valve is opened entirely or not;

the pipe is blocked or not;

the lead seal is complete or not;

Battery is good or not;

heat meter isn’t counting

①,heat meter reversed installation

②,transducer cables are broken

③,the filter is be blocked on heat supply pipe of in the resident room

How to determine the filter whether block?

Inflow temp. is normal, return flow temp. is too low, the temp. difference of inflow and return flow is more than 10°, flow rate is too low(m3/h), or now flow rate, usually the filter is blockage, or user does not use.

Solution:Close the valve (inflow and return flow valve), remove the filter, to observe whether filter is black, clean filter and inside of it, then install the filter, open pipe valves, wait 3 mins to check whether the flow rate and temp. is normal.

Heat meter data abnormal or jumping

①,Installation position is not correct, down water level

②,Front and back straight pipes are too short, bend is too big, front pipe diameter is

changing bigger.

Heat meter has flow quantity, no heat, or heat is very big

①,Without heat is usually reversed installation of inflow and return flow temp. sensors

②,Heat is very big, because the temp. sensor measure temp. incorrectly, temp. difference is very big.

Heat meter abnormal temp., or the temp. is 0

①,the temp. sensor cable is broken

②,Temp. sensor stainless steel casing is broken.

 

Technical Specification

 

DiameterMin FlowQuantity of FlowMax FlowLength
qmin(m³/h)qp(m³/h)qmax(m³/h)mm
DN150.031.53110
DN200.052.55130
DN250.073.57160
DN320.12612180
DN400.21020200
Measurement AccuracyCJ128-2007<Heat Meter>Class 2
ConnectionDN15~DN40 Threaded connection/DN50~DN300 Flange connection
Pressure Loss≤0.02MPa
Maximum Working Pressure(MWP)1.6MPa
Flow Measuring Range1:100
Temperature Sensor1.5m standard a pair of PT1000 Temperature Sensor (cable length could be changed)
Data StorageContinuous store of 18 months record
Power-off ProtectionAfter power-off, meter could save all the record of before flow rate and the corresponding time, after power back, it recovery measure function automatically, and ensure the time continuation
Remote TransmissionMBUS/RS-485
Power SupplyHigh Power Lithium battery
Protection ClassIP67 (IP68 need to modified)
Environmental ClassClass B
Temperature Range(5~95)℃
Temperature Difference(3~90)K
Installation WayInflow or Return flow(Default is Inflow, for return flow need to indicate when ordering)
Installation PositionHorizontal / Vertical
PermanenceService cycle≥6 years
Display8-bit LCD display
Anti-magnetic DisturbanceWhen the intensity of magnetic field interference is not more than 100 ka/m, should not affect water meter measurement and remote transmission characteristics
 

 

Hot Products

GXPS400 Series High Accuracy Submersible Liquid Level Sensor Description GXPS400 series liquid level ...
GXPS400M Split Type High Accuracy Liquid Level Sensor GXPS400M is a split type liquid level sensor ...
Introduction GXPS353 series pressure transmitter is a high-volume, low cost OEM, civil & industrial ...
GXPS353 Refrigeration Industry pressure transmitter 1.Product Description GXPS353 series pressure ...
GXPS550 Female thread Internal thread differential pressure sensor with output 0-10V ​ Introduction ...
GXPS240 High-frequency Water Supply Pressure Transmitter Introduction GXPS240 series pressure ...