Product Details

Wirless Ultrasonic Btu Meter Lora / GPRS Ultrasonic Heat Meter For Residence / Apartments / Buildings

 

Features

 

☆ Measure Heat.
☆ Show supply/return water temperature and differential temperature.
☆ Display pile flow measure and instantaneous flow measure.
☆ Running time display.
☆ Cool measure and display (for heat/cold Ultrasonic Heat Meter )

 

Description

 

KACISE KUHM2100 series heat meters adopt most advanced non-magnetic technology and it features elegant appearance, accurate measurement, convenient management, steady operation, strong anti-erosion, and long using life, which is secure and economic.
It is widely used in the heat system with concentrated heat supplying management, separate household data collecting management.
Varies of communication modes are optional according to the users’ need..

 

Installation and Attentions

The heat meter both can be installed in Inflow pipe or Return flow pipe (factory default installed in the inflow pipe, if need to install on the return pipe, must be clearly indication before the factory during the production). When installation, should pay attention to the flow direction of medium is as the same as the arrow on the heat meter pipe body.

Special note: no matter the heat meter installed on inflow pipe or return flow pipe, the temperature sensor should be properly connected ( red label for inflow pipe, blue label for return pipe)

 

Specifications

 

Nominal DiameterDN15DN20DN25DN32DN40
Dimension (Length mm)110130160180200
Max flow (m3/h)3571220
Norm flow(m3/h)1.52.53.5610
Min flow(m3/h)0.030.050.070.120.2
Max flow reading999999.99(m3)
Max heat reading99999999(KW·h)
Power supply3.6VDC
Battery life>6 years ( Lithium battery)
Accuracy classClass 2
Communication modeInfrared interface , M-BUS/RS485
Press loss≤ 0.025 Mpa ( under normal flow)
IP classIP 68
Temperature range(4--95) °C
Temperature difference range(3--70) k
Starting temperature difference0.01k
Temperature sensorPt 1000
Ambient temperature+5°C -- +55°C
Ambient levelLevel A
InstallationHorizontal/ vertical installation
Monitor8 digits
Length of temperature sensor1.5m
Working current45uA
Data storageStore historical data up to last 24 months

Instrument Common Problem

 

The meter cannot work normally

Heating system is working or not;

Globe valve is opened entirely or not;

the pipe is blocked or not;

the lead seal is complete or not;

Battery is good or not;

heat meter isn’t counting

①, heat meter reversed installation

②, transducer cables are broken

③, the filter is be blocked on heat supply pipe of in the resident room

How to determine the filter whether block?

Inflow temp. is normal, return flow temp. is too low, the temp. difference of inflow and return flow is more than 10°, flow rate is too low(m3/h), or now flow rate, usually the filter is blockage, or user does not use.

Solution:Close the valve (inflow and return flow valve), remove the filter, to observe whether filter is black, clean filter and inside of it, then install the filter, open pipe valves, wait 3 mins to check whether the flow rate and temp. is normal.

Heat meter data abnormal or jumping

①, Installation position is not correct, down water level

②, Front and back straight pipes are too short, bend is too big, front pipe diameter is

changing bigger.

Heat meter has flow quantity, no heat, or heat is very big

①, Without heat is usually reversed installation of inflow and return flow temp. sensors

②, Heat is very big, because the temp. sensor measure temp. incorrectly, temp. difference is very big.

Heat meter abnormal temp., or the temp. is 0

①, the temp. sensor cable is broken

②, Temp. sensor stainless steel casing is broken.

 

Technical Specification

 

DiameterMin FlowQuantity of FlowMax FlowLength
qmin(m³/h)qp(m³/h)qmax(m³/h)mm
DN150.031.53110
DN200.052.55130
DN250.073.57160
DN320.12612180
DN400.21020200
Measurement AccuracyCJ128-2007<Heat Meter>Class 2
ConnectionDN15~DN40 Threaded connection/DN50~DN300 Flange connection
Pressure Loss≤0.02MPa
Maximum Working Pressure(MWP)1.6MPa
Flow Measuring Range1:100
Temperature Sensor1.5m standard a pair of PT1000 Temperature Sensor (cable length could be changed)
Data StorageContinuous store of 18 months record
Power-off ProtectionAfter power-off, meter could save all the record of before flow rate and the corresponding time, after power back, it recovery measure function automatically, and ensure the time continuation
Remote TransmissionMBUS/RS-485
Power SupplyHigh Power Lithium battery
Protection ClassIP67 (IP68 need to modified)
Environmental ClassClass B
Temperature Range(5~95)℃
Temperature Difference(3~90)K
Installation WayInflow or Return flow(Default is Inflow, for return flow need to indicate when ordering)
Installation PositionHorizontal / Vertical
PermanenceService cycle≥6 years
Display8-bit LCD display
Anti-magnetic DisturbanceWhen the intensity of magnetic field interference is not more than 100 ka/m, should not affect water meter measurement and remote transmission characteristics
 

 

Hot Products

High temperature Hirschman connector water tank MEMS diaphragm pressure transducer 0.5% accuracy ...
high accuracy low cost OEM MEMS rubber Machine High Temperature Melt Sanitary Pressure Sensor ...
Kacise Hirsman connector high accuracy low cost OEM MEMS High Temperature Pressure Transducer ...
Introduction GXPS353 series pressure transmitter is a high-volume, low cost OEM, civil & industrial ...
GXPS400 Series High Accuracy Submersible Liquid Level Sensor Description GXPS400 series liquid level ...
GXPS400M Split Type High Accuracy Liquid Level Sensor GXPS400M is a split type liquid level sensor ...