Home Companies DONGGUAN YUYANG INSTRUMENT CO., LTD

EN 13823 250KPa Building Materials Test SBI Single Burning Item Test Machine

DONGGUAN YUYANG INSTRUMENT CO., LTD

Contact Us

[China] country

Trade Verify

Address: B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China

Contact name:Seline Yu

Inquir Now

DONGGUAN YUYANG INSTRUMENT CO., LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

EN 13823 250KPa Building Materials Test SBI Single Burning Item Test Machine

Country/Region china
City & Province dongguan guangdong
Categories Laser Equipment Parts
InquireNow

Product Details

 

EN 13823 Building Material Single Burning Item Test Machine(SBI)

 
Application:
Method of test for determining the reaction to fire performance of building materials and products
excluding flooring,and excluding products which are indicated in the EC Decision 2000/147/EC.
Standard:
EN 13823 Reaction to fire tests for building products ― Building products excluding floorings exposed
to the thermal attack by a single burning item
GB/T 20284 Single burning item test for building materials and products
Operating Conditions:
1. Power supply:AC 220V 50HZ;
2. Power:8.5KW;
3. Ambient temperature: 5~35 ℃;
4. Relative humidity:20%~80%;
5. Atmospheric pressure:0~250KPa.

Specifications:
The test apparatus contains test room,control room,trolley,exhaust duct,data collection analysis
device,gas supply control device.
1. Test room:L3000*W3000*H2400(MM),at the top of room connecting hood with sampling pipe and

exhaust ducting,there is space for natural gas in-out blew the trolley.During testing,the combustion heat
release of sample and combustion production can be discharged from exhaust duct.With brick building.
2. Ignition source,placed on trolley vertical rectangular box in the corner of the 31 kw propane sandbox

burners(two equal sides 0f 250mm,height 80mm);
3. Exhaust pipe is provided with general measurement section for placing sensors and sampling tubes;
4. Exhaust speed: 0.50 m3 /S~0.65 m 3/ S;
5. Test room ambient temperature measurement:K-type sheathed thermocouples with diameter

2mm,ambient pressure test accuracy: ± 200Pa;
6. Flue temperature measurement:K-type sheathed thermocouples with diameter 0.5mm;
7. Temperature measurement accuracy: 0.5 ℃;
8. Flue high-precision pressure sensor accuracy: ± 2Pa;
9. Time recording system accuracy: 0.1S;
10. Test time: 1 to 30 minutes can be set;
11. Smoke density measurement system to measure the density of the smoke during testing;
12. Gas analyzer, and the key components are imported.
1 )Measuring range: 0-25%
2) Signal output: 4-20mA;
3 )Response time T90: ≤2S;
4 )Ambient temperature: 0-45 ℃;
5 )Relative humidity: <90% (non-condensing);
6 )Linearity: <± 0.1% O2;
7 )Zero drift: 0.05% O2 per week;
8 )Repeatability: <± 0.02% O2;
15. Carbon dioxide(CO2) measurement:

1) Measuring range:0-10%;
2) Repeatability: <± 1% internal structure of the control cabinet;
3) Zero drift: ≤2% / week;
4) Span drift: ≤2% / week;
5) Linearity deviation: <± 1%;
6) Response time: T90≤2 seconds;
16. Record data acquisition system can collect oxygen concentration, carbon monoxide concentration,

temperature, smoke density, heat release rate, mass loss rate, etc., can be stored.
Application:
Method of test for determining the reaction to fire performance of building materials and products
excluding flooring,and excluding products which are indicated in the EC Decision 2000/147/EC.
Standard:
EN 13823 Reaction to fire tests for building products ― Building products excluding floorings exposed
to the thermal attack by a single burning item
GB/T 20284 Single burning item test for building materials and products
Operating Conditions:
1. Power supply:AC 220V 50HZ;
2. Power:8.5KW;
3. Ambient temperature: 5~35 ℃;
4. Relative humidity:20%~80%;
5. Atmospheric pressure:0~250KPa.

Specifications:
The test apparatus contains test room,control room,trolley,exhaust duct,data collection analysis
device,gas supply control device.
1. Test room:L3000*W3000*H2400(MM),at the top of room connecting hood with sampling pipe and

exhaust ducting,there is space for natural gas in-out blew the trolley.During testing,the combustion heat
release of sample and combustion production can be discharged from exhaust duct.With brick building.
2. Ignition source,placed on trolley vertical rectangular box in the corner of the 31 kw propane sandbox

burners(two equal sides 0f 250mm,height 80mm);
3. Exhaust pipe is provided with general measurement section for placing sensors and sampling tubes;
4. Exhaust speed: 0.50 m3 /S~0.65 m 3/ S;
5. Test room ambient temperature measurement:K-type sheathed thermocouples with diameter

2mm,ambient pressure test accuracy: ± 200Pa;
6. Flue temperature measurement:K-type sheathed thermocouples with diameter 0.5mm;
7. Temperature measurement accuracy: 0.5 ℃;
8. Flue high-precision pressure sensor accuracy: ± 2Pa;
9. Time recording system accuracy: 0.1S;
10. Test time: 1 to 30 minutes can be set;
11. Smoke density measurement system to measure the density of the smoke during testing;
12. Gas analyzer, and the key components are imported.
 

Hot Products

IEC 60332 Single Cable Vertical Flame Spread Tester Description: Single Cable Vertical Flame Spread ...
ASTM C518 Steady-State Thermal Conductivity Properties Tester by Heat Flow Meter Description: It is ...
BS EN 367 80 kW/m2 Protective Clothing Heat Transmission Tester Introduction: A new term heat ...
AC 220V,50HZ Flooring Radiant Heat Flux Fire Testing Machine Description: This test method is used ...
ASTM E108 Roof External Exposure Fire Spread Tester Used For Wood Burning Test Description: The ...
IEC 60332 Flame Propagation Tester, Single Cable Flame Propagation Testing Machine Description: Wire ...