Home Companies DONGGUAN YUYANG INSTRUMENT CO., LTD

Standard Bunched Cable / Wire Flame Test Equipment With 0.1Mpa Gas Pressure

DONGGUAN YUYANG INSTRUMENT CO., LTD

Contact Us

[China] country

Trade Verify

Address: B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China

Contact name:Seline Yu

Inquir Now

DONGGUAN YUYANG INSTRUMENT CO., LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Standard Bunched Cable / Wire Flame Test Equipment With 0.1Mpa Gas Pressure

Country/Region china
City & Province dongguan guangdong
Categories Cable Manufacturing Equipment
InquireNow

Product Details

Standard Bunched Cable and Wire Flame Testing Equipment 0.1Mpa Gas Pressure

 

 

Scope:

 

This machin is used for bundled cables under the conditions specified in the ability to inhibit the spread of flame, and its use of the cable: that is, power, communications and other unrelated.

 


The main components:

 

1, the ignition control system

2, the collection tower and smoke device

3, gas flow control system

4, smoke concentration measurement system

5, temperature control system

6, flame control system data acquisition:

  • flow measurement
  • temperature measurement
  • speed measurement
  • smoke measurement and other data collection


Main Specifications:

 

1, The wall (concrete brick wall 1698kg / m3), the inner surface of the black tiles, the building can withstand high temperatures and flames burning.

2, The door: 0.9 × 2m (W × H) is not through the steel frame, tempered glass.

3, The thermal conductivity for the interior is 37.8 ° C when the outside temperature is 23.9 ° C.

4, Smoke collection tower inclination of 40 degrees angle, the top of the cube is 914mm. The filter is 610 sides long.

5, Observation window length is 457 ± 25 mm, three sides (except the door side) to the ground below the distance of 1295 ± 25 mm, the right to the wall distance 1143 ± 25 mm

6, Air inlet: 559 × 343mm (± 6mm), 914 × 305mm (± 6mm), 2438 (± 25mm) × 343mm (± 6mm)

7, Exhaust pipe 406mm diameter, horizontal installed in the collection tower on the right side of the cube

8, Anemometer measurement area ground fire mouth base up 1.5m, the base is 305 × 76 × 152mm

9, Ladder height 2400mm, cross-section of 305 × 25 × 25 mm (L × W × H) Square, the distance between the two cross-299 mm

10, The fire mouth flat length 341 mm width 30 mm on the 242 fire eyes, fire eyes long 257 mm, the distance between the two horizontal fire eyes 3.2 mm, the vertical distance between two fire eyes 2 mm, the distance between the three fire 5 mm

11, The indoor wind speed ≤ 1m / s speed

12, The gas flow 13.2L / M, gas pressure 0.1Mpa

13, 2438mm × 2438mm × 3353mm (test requirements: 14.5m ≤ brick wall internal area ≤ 36m)

 

 

 

Hot Products

Tag Closed Cup Auto Flash Point Analyser, ASTM D56 Fire Testing Equipment Description: TAG Closed ...
High Precision 0.7 Cubic Meter Toxicity Index Test Apparatus NES 713 Description: The NES 713 is ...
ASTM D3675 Fire Testing Equipment Radiant Panel Flame Spread Surface Test Apparatus Description: The ...
ASTM E1354 Fire Testing Equipment ISO 5660 Heat Release Rate Cone Calorimeter Description: The Cone ...
GB/T 20284, EN ISO13823 Construction Materials Single Burning Item Fire Testing Equipment Descriptio...
ISO 9705 Surface Products Full Scale Room Corner Test Heat Release Rate Fire Testing Equipment ...