Home Companies Dongguan HOOHA Electrical Equipment Company Limited

Adjustable Temperature Horizontal Flammability Tester For Integrity Testing 1KW

Dongguan HOOHA Electrical Equipment Company Limited
Active Member

Contact Us

[China] country

Address: ROOM 1205, 12/F, TAI SANG BANK BUILDING, 130-132 DES VOEUX ROAD,CENTRAL, HONG KONG

Contact name:Jack young

Inquir Now

Dongguan HOOHA Electrical Equipment Company Limited

Adjustable Temperature Horizontal Flammability Tester For Integrity Testing 1KW

Country/Region china
City & Province hong kong hong kong
Categories Electric Wrenches
InquireNow

Product Details

Adjustable Temperature Horizontal Flammability Tester For Integrity Testing 1KW

 

Scope of application:


Suitable for testing cable or optical cable under the flame of not less than 750 ℃, for when the fire is keep line integrity, and test cable or optical cable in not less than 830 ℃ for offensive and exert impact conditions, whether to keep the line’s integrity.

 

Meet the standard:


In line with the GB/T19216.11 also 99-2003 / IEC60331 - "under the condition of fire cable and optical fiber cable line integrity test part 11: test unit - the flame temperature is not lower than 750 ℃ separately for fire" standard requirements;

Comply with GB / / IEC60331 T19216.12-2008-02 deprives the under the condition of fire cable or optical cable circuit integrity test part 12: test apparatus, the flame temperature is not lower than 830 ° C for offensive and exert impact "standard requirements;

In accordance with GB/T19216.21-2003/ iec60331-21:1999, line integrity test of cables and cables under flame conditions section 21: test procedures and requirements - rated voltage 0.6/1.0kv and the following cables;

In accordance with GB/T19216.23-2003/ iec60331-23:19 99, line integrity test of cables and cables under flame conditions section 23: test procedures and requirements - data cables;

In accordance with GB/T19216.25-2003/ IEC60331-25:19 99 in the flame condition, the circuit integrity test of cables and cables is part 25: test procedures and requirements - optical cable;

In accordance with GB/t19216.31-2008 / iec60331-31:2002, the line integrity test of cables and cables under flame conditions section 31: test procedures and requirements for fire and impact - rated voltage 0.6/1.0kv and below cable.

 

Main features:


Control system:

Using the assembly control system and high performance acquisition control card, automatic data acquisition and processing, data saving and output results can be realized.

The equipment has the following safety protection devices: power overload, short circuit protection and overload protection of control circuit. It has power failure, short circuit, alarm, indicating fire breakdown current: 3A (automatic alarm cut-off power and gas supply system after sample breakdown).

Adopt imported high quality devices to ensure high quality, high speed and stable operation and advanced technology.

The automatic control mode test is adopted to realize automatic detection control, automatic completion of detection work, and humanized control interface, making the detection work more convenient, faster and more accurate.

Automatically generate temperature control curve and report output, data collection and printing test results.

 

Main parameters:


The main four components of the circuit integrity tester of cable and optical cable are the combustion chamber, combustion system, control room and assembly control system.

Burner: a type propane gas burner with a 500mm length of flame surface with venturi mixer. The nominal width of the fire-breathing surface is 15mm, and the nominal diameter of three rows on the fire surface is 1. 32mm, center distance is 3. 2mm drilling.

Gas control system: the control valve, high-pressure automatic ignition and flameout device, the control thermocouple, propane, spiral valve, pressure gauge, flow meter, venturi mixer, burner, ball valve, compressed air tank, etc.

Flame temperature: 750 ° ~ 1000 ° is adjustable.

Combustion gas: a purity of 98 % propane.

Combustion gases: compressed air. (air pressure should be above 10Mba.)

Flow meter: the rotor flow meter is used.

Air flow: 0~ 200L/min.

Propane (gas) flow: 0~ 20L/min. Flow adjustable.

Thermocouple: vertical thermocouple, horizontal thermocouple.

Validation decision: two thermocouples in 10 min time average readings within the (750 + 050 ℃) requirements, and the maximum difference in the two thermocouple readings average no more than 40 ℃, should think through validation.

Validation average: at least every 30s.

Verification timer: 0~ 99. The 99min will automatically stop when it reaches the set value.

Verify accuracy: plus or minus 1s/h.

Ignition device: automatic ignition with high voltage pulse.

Supply time: 0-999min

Power supply requirements: AC380 (plus or minus 10%) V/50HZ.

Machine operation power: 1KW.

Test voltage (phase voltage) : 0-1000v continuously adjustable.

GB/T19216.25 standard continuity inspection device: optical instrument continuity check, optical instrument customer self - preparation.

 

Technical services:


1. 20 years of brand commitment, patent quality, quality assurance, superior performance, excellent quality and full service;

2. 20 years of brand communication, professional team, professional technical and technical consultant, and the cooperation of various quality inspection institutes and schools;

3. Provide free service for the whole year, five quality control procedures, from material input to product handover control quality, ensure that the user is absolutely authentic;

4. The brand effect absolutely guarantees the quality of the products, and we provide high quality products with high quality products and the highest cost performance to ensure the testing data, and the guarantee of the company;

5. 18 professional technicals will solve any problem in your products. Professional after-sales team will provide you with the most beautiful service;

6. Free teaching research, equipment maintenance and free upgrade of equipment server;

Your doubts are solved by us. What are you worried about? Pick up the phone in your hand and order.

Hot Products

ZY6235 Pavement Material Radiant Heat Flux Test Device With Powerful Exhaust System Scope of ...
wire and cable test machine QJ57 DC Kelvin Bridge wire and cable test machine Product description: ...
HH62112 Series Bridge Fixtures cable test machine Product description: Bridge fixture in line with ...
IEC 60335 Withstand Voltage Test Instrument IEC 60335 Product description: Withstand voltage test ...
GB/T3048.5-2007 ZC-90 Series Insulation Resistance Meter GB/T3048.5-2007 ZC-90 Series Insulation ...
GB / T2951.11-2008 HH31113 Intelligent Auto Profile Projector Intelligent Auto Profile Projector ...