Changzhou Fanjin Drying Equipment Co., Ltd. |
WORKING PRINCIPLE
The fuel is burnt at the burner to produce high temperature gas.
The heat will conduct to the air by the heat exchange device. The
temperature of the high temperature gas will dropped to less than
250°C and then discharged. The clean air is pushed to hot air
furnace by the blower. The hot air will be sent from the vent after
absorbed heat up to the rated value. When the temperature of hot
air reaches the rated upper limit, the burner will stop burning or
turn down to a small fire automatically. When the temperature of
hot air drops to the rated low limit, the burner start to burn or
turn up to a big -fire automatically.
APPLICATION
This furnace is widely used for curing, heat-setting, and drying in
various industries such as pharmaceutical, chemical, food, textile,
food processing, wood processing, automobile, and etc.
TECHNICAL PARAMETER
Model | Burner | oil combustion (kg/h) | Capacity (104 kcal/h) | Overall dimensions L×W×H (mm) | Hot air inlet L×W (mm) | Total weight (kg) |
RLY1 | RIELLO.G3/DL3FS | 1.3-1.6 | 1 | 1200×1200×1600 | 200 | 460 |
RLY4 | RIELLO.G10/DL10FS | 5-6.5 | 4 | 1700×1300×1600 | 250 | 850 |
RLY10 | RIELLO.G20/DL23FS | 13-16 | 10 | 2300×1568×1870 | 300 | 2200 |
RLY20 | RIELLO 1G/DL34FS | 26-32 | 20 | 2800×1568×1870 | 400 | 2670 |
RLY30 | RL50/DL55FT | 39-48 | 30 | 3400×1568×1870 | 450 | 3060 |
RLY40 | RL70/DL75FT | 52-64 | 40 | 4440×1768×2070 | 550 | 5600 |
RLY60 | RL100/DL100FT | 78-96 | 60 | 5140×1868×2070 | 600 | 8460 |
RLY100 | PRESS 4G/DL 120FT | 130-140 | 100 | 6440×2480×2300 | 550×600 | 12800 |
RLY160 | P300/DL250FT | 200-270 | 160 | 7470×2920×3480 | 750×900 | 15780 |
RLY200 | P300/DL300FT | 260-300 | 200 | 8175×2920×3480 | 750×900 | 18500 |
RLY360 | G1510 | 480-620 | 360 | 9300×2920×3480 | 2100 |