Home Companies DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

ASTMF2101 Mask Tester Evaluating Bacterial Filtration Efficiency BFE Of Medical Face Mask Materials Bioaerosol

DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.168 Zhen'an West Road Changlian Industry Mansion Xiabian Community Dongguan China

Contact name:Sophia Su

Inquir Now

DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

ASTMF2101 Mask Tester Evaluating Bacterial Filtration Efficiency BFE Of Medical Face Mask Materials Bioaerosol

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials, Using a Biological Aerosol of Staphylococcus aureus  EN14683-2019,ASTMF2299/F2299M-03(2017)
 
Product overview:
Medical external mask bacterial filtration efficiency (BFE) detector
 
Standards:
- ASTMF2101
- EN14683-2014.
 
Technical Parameters:
Technical characteristics of mask bacterial filtration efficiency (BFE) detector
2.1 Negative pressure experiment system to ensure the safety of operators;
2.2 Built-in peristaltic pump in negative pressure cabinet, A and B two-stage six-stage Andersen;
2.3 Flow rate of peristaltic pump can be set;
2.4 Dedicated microbial aerosol generator can be set at night.
2.5 atomization effect is good;
2.6 Embedded high-speed industrial microcomputer control;
2.7 10.4-inch industrial-grade high-brightness color touch display;
2.8 USB interface, support U disk data transfer;
2.9 Cabinet with built-in high-brightness lighting;
2.10 Built-in leakage protection switch to protect operator safety;
2.11 The inner layer of the stainless steel is integrally processed and formed, and the outer layer is spray-coated cold-rolled sheet
2.12detachable bracket, height of bracket can be adjusted;
2.13 Support and move dual-purpose casters.

 

Technical index:

Main parameters

Parameter range

Resolution

Maximum allowable error

A channel sampling flow rate

28.3L/min

0.1L/min

better than ±2.5%

B channel sampling flow rate

28.3L/min

0.1L/min

better than ±2.5%

Spray flow

(8~10)L/min

0.1L/min

better than ±5.0%

Peristaltic pump flow

(0.006~3.0)mL/min

0.001ml/min

better than ±2.5%

Front pressure of channel A

(-20~0)kPa

0.01kPa

better than ±2.5%

Front pressure of channel B

(-20~0)kPa

0.01kPa

better than ±2.5%

Pressure before spray flowmeter

(0~300)kPa

0.1kPa

better than ±2.5%

Aerosol chamber negative pressure

(-90~-120)Pa

0.1Pa

better than ±2.0%

Operating temperature

(0~50)℃

Cabinet negative pressure

(-50~-200)Pa

Data storage capacity

>100000 group

HEPA filter characteristics

Filtration efficiency for particles above 0.3um ≥99.99%

Aerosol generator mass median diameter

Average particle diameter (3.0 ± 0.3) μm, geometric standard deviation ≤1.5

Dual 6-stage Anderson sampler captures particle size

Ⅰ>7μm,Ⅱ(4.7~7)μm,Ⅲ(3.3~4.7)μm,Ⅳ(2.1~3.3)μm,Ⅴ(1.1~2.1)μm,Ⅵ(0.6~1.1)μm

Aerosol chamber specifications

(Length 600 x diameter 85 x thickness 3) mm

Total number of positive QC sampler particles

(2200±500)cfu

Negative pressure cabinet ventilation flow

≥5m3/min

 
 

Hot Products

ISO 9151 Protective Clothing Heat Transmission Tester BS EN 367 Product Description: Heat transfer ...
600°F Flame- Retardant Protective Clothing Testing Equipment GB 8965.1.2009 Scope of application: ...
CSN EN 136 Fire Testing Equipment Full Cover Thermal Radiation Tester Product Brief: The mask heat...
ISO9185 Protective Clothing- Resistance Of Materials To Molten Metal Splash Testing Equipment ...
ISO 17492 TPP Thermal Protection Performance Tester NFPA 1971 Application: TPP thermal protection ...
ISO 17492 Clothing For Protection Against Heat And Flame- Heat Transmission On Exposure NFPA 1971 ...