Sichuan Chuanxiao Fire Trucks Manufacturing Co., Ltd. |
Verified Suppliers
|
|
1. 6x6 Airport ARFF Fire Fighting Truck China Manufacturer for Fire Engine
This vehicle is a special fire-fighting vehicle for the airport. It has strong power and excellent road passing ability. It can arrive safely and quickly for fire-fighting and rescue.The detailed parameters are as follows.
2. The Whole Fire Truck's Parameters
No. | Main Items | Technical Parameters |
2.1 | Model | SXF5322GXFJX110/B |
2.2 | Overall Dimension | 9800mm×2500mm×3900mm |
2.3 | Full Load Weight | 27100kgs |
2.4 | Number of the Crew | 3 (include driver) |
2.5 | Max. Speed | 100km/h |
2.6 | Capacity | 10000L Water & 1000L Foam. PP composite material liquid tank |
2.7 | Fire pump flow rate | 100L/s @ 10bar |
2.8 | Fire monitor | 100L/s flow rate, 80m shoot range |
2.9 | Painting | Red paint of U.S. PPG |
3. Benz Chassis
Manufacturer: Germany Benz
Model: Benz Arocs 3358
Drive type: 6*6
Wheelbase: 4450mm+1450mm
Engine model: OM473
Engine type: Inline 6-cylinder, turbocharged, inter-cooled diesel
engine
Rated power: 425Kw
Gearbox form: Automatic transmission, 16 forward gears + 4 reverse
gear
Fuel tank capacity: 290L
4. Fire Extinguishing System
4.1 Fire Pump
Flow Rate: 100L/s @ 10bar
Vacuum Pump: Integrated design with the water pump, directly driven
by the pump shaft, no need for additional power, no noise
Priming Manner: Automatic
Suction Height: 7m
Priming Time: ≤80s
Location: Rear mounted
4.2 Fire Monitor
Flow Rate: 100L/s @ 10bar,adjustable flow
Shoot Range: Water ≥ 90 m, Foam ≥ 85 m
Location: On the top of the tank
Control Manner: Remote control
Horizontal Rotation Angle 0°~330°
Pitch Rotation Angle: -15°~60°
4.3 Liquid Tank
Capacity: Water 10000L, Foam 1000L.
Material: PP composite material and Never Rust.
Structure: Two Tank Manhole; One Overflow Device/Pressure Relief
Device; Two Liquid Level Indicators; One Foam tank Drain Outlets
with Valves; One Water tank Drain Outlets with Valves.
4.4 Control Panel
Structure: Each fire extinguishing system is controlled by PLC, and
different standardized control modules can be selected. IP56
protection level.
Location: In middle pump room.
5. Company Pictures for Reference