Home Companies WWHS Biotech.Inc(exclusive marketed by Dawin)

CA15-3 Antigen Rapid Test Kit 3000 Tests/Day IVD Tumor Marker

WWHS Biotech.Inc(exclusive marketed by Dawin)

Contact Us

[China] country

Trade Verify

Address: Rm 505, 1st Building, Shenzhen Biomedicine Innovation Industrial Park, No. 14th, Jinhui Road, East Jinxiu Road, Kengzi Street, Pingshan District, Shenzhen

Contact name:Richard

Inquir Now

WWHS Biotech.Inc(exclusive marketed by Dawin)

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

CA15-3 Antigen Rapid Test Kit 3000 Tests/Day IVD Tumor Marker

Country/Region china
City & Province shenzhen
Categories Respiratory Equipment
InquireNow

Product Details

【Product name】
Carbohydrate Antigen 153(CA153)Rapid Quantitative Test(Fluorescence immunoassay)
 
【Package specification】
  25 Tests/kit
 
【Inspection principle】
  The CA153 Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of CA153. The CA153 antigen in the sample was first bound with the conjugated compound of fluorescent labeled CA153 monoclonal antibody, then moved and combined with another CA153 monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.
 
【Components】

 NameQuantityComponent
Test cards25It is composed of fluorescent pad (coated with fluorescent labeled CA153 monoclonal mouse antibody), nitrocellulose membrane (coated with CA153 monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent25(300μL/tube)Phosphate buffer
ID card1With specific stand curve file

 
 


The components in different batches of kits cannot be used interchangeably.

 

 

【Limitations of methods】

 1,This kit is only used to detect human plasma/whole blood samples

 2,Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.

 3,The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.

 4,When the concentration of CA153 in the sample is less than 500U/ml, there is no hook effect.

 5,HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.

 6,When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

 

【Procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
  3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
  4. Place the test card on a clean horizontal table and mark it horizontally.
  5. Mix 100µL of patient sample with 300µL of sample diluent. Apply 100µL of diluted samples to the well of the test card.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, read and record the results at 15 minutes after addition of samples, then dispose of used test appropriately.

 

 【Note】

  1. This kit is only used for in vitro diagnosis.

  2. The test card and sample diluent are disposable and cannot be reused.

  3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

  4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.

  5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.

 
WWHS Assay List
 

Tumor Marker     
cat#.Product itemSpecimenReaction TimeMeasure RangeClinical RangeItended Use
20AFPSerum/Plasma15min.2.5-200ng/ml<20ng/mlpregnancy cancer
21CEASerum/Plasma15min.1-200ng/ml<5ng/mlcolon cancer, colorectal cancer,etc.
22NSESerum/Plasma15min.1-400ng/ml<16ng/mlnon-small cell lung cancer
23FOBfecal specimens10min.50-1000ng/ml<100ng/mlAbnormal recessive gastrointestinal bleeding
24PG IISerum/Plasma15min.1-100ug/LPGI/PGII>3.0gastric abnormalities
25PG ISerum/Plasma15min.2.5-200ug/L>70ng/mlgastric abnormalities
26TPSASerum/Plasma15min.0.5-40ng/ml<4ng/mlprostate cancer
27FPSASerum/Plasma15min.0.1-10ng/ml<1ng/mlprostate cancer
28CA12-5Serum/Plasma15min.20-500U/ml<35U/mlovarian cancer
29CA15-3Serum/Plasma15min.10-400U/ml< 25 U/mLbreast cancer
30HE4Serum/Plasma15min.50-2000pmol/L<140 pmol/Lovarian cancer
31CA19-9Serum/Plasma15min.10-400U/ml< 27 U/mLpancreatic cancer
32β-HCGSerum/Plasma15min.5-400mIU/ml<10 mIU/mLEarly pregrancy, ectopic HCG cancer,incomplete abortion
33CK19(Cyfra21-1)Serum/Plasma15min.0.5-50ng/ml<2.5ng/mlnon-small cell lung cancer

 



 

 
FAQ
1. What is fluorescent immunoassay analyzer?

The Biopanda Fluorescence Immunoassay Analyser is used by small labs for the detection of a range of biomarkers to assist with the diagnosis and monitoring of several medical conditions including cardiovascular disease, inflammation, kidney disease, thyroid conditions, and fertility.
2. Do you have CE certificate for immunoassay analyzer?
WBC analyzer belongs to IVD other/general, no need CE, Ec declaration is enough.
3. How does fluorescence immunoassay work?
Fluorescent Immunoassays are simply a different type of immunoassay. ... A modern fluorescent based immunoassay uses as the detection reagent a fluorescent compound which absorbs light or energy (excitation energy) at a specific wavelength and then emits light or energy at a different wavelength.
4. What is indirect immunofluorescence assay?
Indirect immunofluorescence, or secondary immunofluorescence, is a technique used in laboratories to detect circulating
autoantibodies in patient serum. It is used to diagnose autoimmune blistering diseases.
5. Is immunofluorescence an immunoassay?
Immunofluorescence assay (IFA) is a standard virologic technique to identify the presence of antibodies by their specific ability to react with viral antigens expressed in infected cells; bound antibodies are visualized by incubation with fluorescently labeled antihuman antibody.
 

Hot Products

CTnI Cardiac Troponin I Test Kit WWHS FIA POCT(Fluorescence Immunoassay) [Product Name]cTnI.pdf ...
Product Name Creatinekinase MB Rapid Diagnostic Kit (Immunochromatography) Intended Use CK-MB is one ...
Product name Lp-PLA2.pdf Diagnostic Kit for Lipoprotein-Associated Phospholipase A2(Immunochromatogr...
D-Dimer test kit Help hospitals quickly target suspected patients and increase productivity.Many ...
【Product name】NT.pdf N-terminal prohormone of brain natriuretic peptide (NT-proBNP) Rapid Quantitati...
【Product name】D-Dimer.pdf D-Dimer Rapid Quantitative Test(Fluorescence immunoassay) 【Package ...