CM Wire V Taper Endo Rotary Files For Root Canal
Treatment(compatible with Vortex Blue)
V-Taper | Size/Taper | Toque(G-CM) | Speed(RPM) | Color |
---|
#15/.04 | 75 | 500 | white |
#20/.04 | 75 | 500 | yellow |
#25/.04 | 104 | 500 | red |
#30/.04 | 104 | 500 | blue |
#35/.04 | 132 | 500 | green |
#40/.04 | 132 | 500 | black |
#45/.04 | 132 | 500 | white |
#50/.04 | 132 | 500 | yellow |
#15/.06 | 195 | 500 | white |
#20/.06 | 195 | 500 | yellow |
#25/.06 | 290 | 500 | red |
#30/.06 | 290 | 500 | blue |
#35/.06 | 368 | 500 | green |
#40/.06 | 368 | 500 | black |
#45/.06 | 368 | 500 | white |
#50/.06 | 368 | 500 | yellow |
Operation Sequence
– Establish patency by taking a #10 K-File past the canal terminus,
and at least a #15 K-File to the terminus.
--In small canals (mesials/buccals of molars, small premolars and
lower anteriors) start with a 30/.04 rotary file. Take 30/.04 to
resistance or working length (whichever occurs first). If
resistance is encountered before working length is obtained, go to
next smaller instrument following the same protocol until working
length is achieved. Between each rotary file recapitulate with a
#10 or #15 tip hand file to maintain glide path and help irrigate
(NaOCl) to the canal terminu
– In larger canals (palatal/distals of molars, larger premolars,
upper anteriors) begin with a 40/.04 rotary file. Use the crown
down technique to resistance or working length. If resistance is
encountered before working length is achieved, move on to smaller
sized instruments until working length is achieved. Between
instruments, recapitulate with small hand instrument to maintain a
glide path to working length.
V Taper properties
V Taper utilizes a unique approach in wire processing that
increases cyclic fatigue resistance and improves torque strength.
Due to this proprietary processing, V Blue files may appear
slightly curved, as demonstrated in the image below. This is not a
manufacturing defect. While the file can be easily straightened
using only your fingers, it is not necessary to straighten the file
prior to use. Once inside the canal the V Blue file will follow the
anatomy, conforming to natural curvatures
Advantage
Minimum of 65% improvement in cyclic fatigue resistance over M-wire
NITI
Minimum of 99% improvement in cyclic fatigue resistance over
standard NITI
Maximum results up to 353% better