Home Companies Shenzhen Feihuan Medical Instruments Co., Ltd

High Efficiency Root Canal Preparation Instruments Circular Cutting Edge

Shenzhen Feihuan Medical Instruments Co., Ltd
Active Member

Contact Us

[China] country

Address: 1305,Wensheng Center, Wenjin Sq., Tianbei 1st Rd., Luohu District, Shenzhen City, China

Contact name:Eileen Li

Inquir Now

Shenzhen Feihuan Medical Instruments Co., Ltd

High Efficiency Root Canal Preparation Instruments Circular Cutting Edge

Country/Region china
City & Province shenzhen guangdong
Categories Rubber Product Making Machinery Parts
InquireNow

Product Details

High Efficiency Root Canal Preparation Instruments , Peeso Reamers In Endodontics

 

Peeso Reamer Stainless Steel Assorted Size #1 - #6 for Access Preparation

 

 

Specifications:

 

Product NamePeeso Reamers
Brand NameProfa
MaterialStainless Steel
LengthL28mm & L32mm
Size DeterminationSize 11 ring
Size 22 rings
Size 33 rings
Size 44 rings
Size 55 rings
Size 66 rings
DiameterSize 10.5mm
Size 20.7mm
Size 30.9mm
Size 41.1mm
Size 51.3mm
Size 61.5mm
Recommended Rotary Speed800-1200 RMP

 

 

Description:


1. Head : Circular cutting edge is good to prevent the steps and impalement .

2. Special process : specially designed, if broken, broken parts is closed to handle , which is easy to

    remove from the root canal .


3. Handle : Each Size has different rings to distinguish , used for preparation of upper 1/3 root canal

    crown ; to bring out the filled material in the root canal; to prepare the post path . 

 

4. Recommended Rotary Speed : 800~1200 rmp

 

 

Operation Sequence :

 

1. To be applied in pulp canal protective ;

 

2. To bring out the filled material in the root canal ;

 

3. To prepare the post path ;

 

4. To prepare the upper 1/3 part of molar root canal crown.

 

 

Warning :

 

1. Only skilled dentists are allowed to use .

 

2. Be sure to sterilize this product for each use .

 

3. Do not use this product except for the dental service and treatment . Use it in accordance with the

    intended use .

 

 

Precautions for use

 

1. To prevent infection , sterilize the product by autoclave and make sure sterilization is completed before

    using.

 

2. Choose the most appropriate type for each case and follow the general method .

 

3. Before using , make sure the instruments outside of dental cavity that there are no deformations ,

   scratches and cracks .

 

4. If the head of product is thin , long or large , there are possibilities for breaking or twisting . Because of

    this , be sure to avoid using unreasonable angle and excessive pressure .

 

5. Wear safety glasses to protect your eyes from damage . Also , wear a dust protective mask to prevent

    inhaling dust .

 

6. Wear rubber dam etc . to avoid accidental ingestion and falling .

 

7. Do not use this instrument for any purposes except for listed applications above .

 

8. Only for use by dentists .

 

9. After using , follow an appropriate treatment as medical waste .

 

10. Dispose the product if damaged or contaminated .

 

11. After using , wash it with medical cleaning agent and brush , then wash away foreign substances like

      adherent body fluids and body tissues .

 

12. Set the handle plugger to a stand when cleaned by ultrasonic cleaner to avoid working part

      deterioration .

 

13. Use handle plugger with great care to avoid puncturing fingers because of its possession of sharp-

      edged part .

 

 

Maintenances and Inspections

 

1. Sterilize this product by autoclave under established method and term for each use.

 

    Method of sterilization:

 

    Put this product in a sterilization pack or (or foil) and place it on a sterilization tray, or files stand for

    autoclave sterilization with reference to the following terms.

 

    Terms for sterilization :

 

    term ( 1 ) temperature : 121degrees Celsius time: 20 minutes or more

 

    term ( 2 ) temperature : 126degrees Celsius time: 15 minutes or more

 

2. Do not use high pressure steam sterilizer which heats more than 200 degrees Celsius including drying

    process .

 

3. When reusing the instrument, wash away foreign substances completely and sterilize .

 

4. Regarding use of medical cleaning agent, follow the instruction manual by its manufacturer strictly .

 

5. Dispose the product if damaged or decreased in performance

 

 

Applications :

 

Dental Root Canal TreatmentHospital , Clinic , lab ...

 

 

Competitive Advantage :

 

1. Imported high quality raw materials 

 

2. High corrosion resistance

 

3. Better equilibrium and stability of hardness 

 

Hot Products

Size S1 Niti Files Endodontics Voilet Root Canal Instruments With ISO Approved NITI Super Files Gold ...
NITI Super Files Gold Material Endo Hand Files For The Formation Of 1/3 Root Canal Tip They are ...
Super Files Gold Hand use NITI Material Assorted Size ISo Color Dental Material with Silicon Stopper ...
NITI Super Files Gold Hand File like Protaper Gold with M-wire Material Size F4 ISO Yellow Root ...
Blue M Wire Endodontic Files Size F3 With Advanced Nano Gold Plating Technology NITI Super Files ...
NITI M Wire Material Endo Hand Files Gold With Good Fracture Resistance NITI Super Files Gold Hand ...