Home Companies Sinuo Testing Equipment Co. , Limited

Programmable Constant Humidity Temperature Test Chamber 1200L IEC60068-2 SINUO

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Programmable Constant Humidity Temperature Test Chamber 1200L IEC60068-2 SINUO

Country/Region china
City & Province guangzhou guangdong
Categories Other Measuring & Analysing Instruments
InquireNow

Product Details

 

1200L Programmable Constant Temperature And Humidity Test Chamber


Complied Standards & Clauses


 

IEC60068-2-1:2007  Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT

 

IEC60068-2-2:2007  Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT

 

IEC60068-2-30:2005  Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT

 

IEC60068-2-78:2012  Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT


 
Technical Parameters


 
No.ProjectContent
AProduct numberSN881-1200L
BProduct brandSINUO
CStudio sizeD1450 x W1250 X H2050 (without motor) mm
Working Area DimensionsCabinet part: about 1000 D × 1000W × 1200H mm
DTemperature range-55℃~+100℃(range adjustable)
Humidity range25%-98% RH (refer to the temperature and humidity controllable range chart, no moisture source or heat load)
Temperature uniformity≤±2.0℃ (stable state)
Heating rate1.0℃/min (no load)
Cooling rate3.0℃/min (no load)
Temperature fluctuation≤±0.5℃ (stable state)
Temperature deviation≤±2.0℃
Humidity deviation≤±3.0%RH
Load

1000 w at +20°C;

800 w at 0°C;

500 w at -20°C;

300 w at -40°C.

EMotor noise≤85dB
WeightAbout 780kg
FApplied standards

GB/T 2423.1-2008 Test A: Low temperature test method

GB/T 2423.2-2008 Test B: High temperature test method

GB/T 2423.3-2006 Test Ca: Constant Damp Heat Test

GB/T 2423.4-2008 Test Db: Alternating Damp Heat Test

GJB 150.3A-2009 High temperature test

GJB 150.4A-2009 Low temperature test

GJB 150.9A-2009 Damp heat test

GBT 5170.8-2016 Inspection of Environmental Test Equipment for Electrical and Electronic Products

GJB150A-2009 Laboratory Environmental Test Methods for Military Equipment

GNoteThe above performance indicators are the values measured at room temperature +25°C without sample.
 
 

Equipment Overview


 

This test chamber simulates the temperature and humidity changeable environment for the products or materials. It is widely used in the adaptability test of electrical, electronics, instrument and meter and other product parts under high and low temperature and humid environment during storage, transportation and usage, to determine the temperature adaptability of the above products or materials to high and low temperature and humid environment, especially for product electrification changes in performance and mechanical properties.

 

MaterialInner box materialCold-rolled steel plate, pickling and phosphating high-grade powder paint
Outer box materialSUS304# stainless steel plate
Insulation materialRigid polyurethane foam + ultra-fine glass fiber
StructureAir duct partsCentrifugal fan; the air outlet can adjust the air volume, height and return air volume
Door(Double) Open hinged door, with handle-type non-reaction handle, equipped with observation window, lighting, window frame/door frame anti-condensation electric heating device, door size: (approx.) 1.0*1.2M
Test windowThere is a conductive film explosion-proof tempered glass observation window on the door (with anti-condensation function) 500W×600H (mm)
FanLong axis centrifugal fan
Sample holderTwo built-in stainless steel adjustable movable trays
ImpellerImported stainless steel impeller from Taiwan
HeaterNickel-chromium alloy electric heater
Refrigeration CompressorsImported Tecumseh compressor
EvaporatorFinned evaporator
Cooling methodMechanical compressor cascade
Cooling methodAir cooling
Temperature control instrument7-inch intelligent LCD touch programmable controller
Lead holeφ50mm 2 with special foam rubber stopper (located on the left side of the box)
 Sample holder2 stainless steel sample racks, height adjustable.
 

Heating, humidifying and cooling systems and how they work

 

ProjectPrinciple description
Heating systemStainless steel tube sleeve type anti-dry heating tube with built-in nickel-chromium alloy heating wire
U-shaped fin type stainless steel high-speed heating electric heater for heating
Completely independent system, does not affect the control line
Humidification systemHumidifier method

1. External detachable boiler humidification method or built-in water tank humidification

2. Stainless steel armored humidifier

3. Humidifier control mode: non-contact equal period pulse width adjustment, SSR (solid state relay)

4. Water level control device, humidifier anti-dry burning device, sediment collection device, liquid level observation window

5. Humidifier power: 6KW

Humidifier

1. Automatic water supply device or push-button electric automatic water replenishment

2. RO membrane + activated carbon water supply filter, removable for cleaning

3. High and low temperature double water level electronic liquid level switch to prevent mis-operation

4. Water shortage and empty heating and over-temperature protection + ultra-low water level protection + water supply over-time protection to ensure the safe operation of the equipment

Refrigeration systemCooling methodAir-cooled
Refrigeration compressorAdopt imported Taikang compressor, use environmentally friendly refrigerant
Refrigerant copper tubeInternal spiral K-TYPE refrigerant copper tube
CondenserCorrugated fin type air-cooled condenser
EvaporatorSlope type FIN—TUBE evaporator
Freezing elementOriginal imported solenoid valve, drying filter, etc.
FeaturesThe whole system pipelines are tested for leak detection by ventilating and pressurizing 22kg.
Heating and cooling systems are completely independent
Equipped with the company's professional technical characteristics, it can prevent the high temperature and high-pressure airflow from returning to the cooling machine and damage the system.
All refrigeration system action programs are completely controlled by microcomputer controller
 
Electrical control system
 
NameBrandRemark

Compressor

Imported Tecumseh compressor

Pressure relay

Denmark DANFOSS

or Emerson

Evaporating pressure regulating valveDenmark DANFOSS

Denmark DANFOSS

or Emerson

Throttling deviceCapillary or Expansion Valve

The electromagnetic valve

Sagittarius in Japan or CASTEL in Italy or Emerson in the United States
 

Adjustment System

 

ProjectIllustrate
Adjustment method

Forced circulation ventilation, balanced temperature regulation. The control system controls the output of the heater according to the temperature point set by the system through the result of PID automatic calculation output, and finally achieves a dynamic balance.

Circulation deviceThe built-in air-conditioning room, circulating air duct and long axial flow fan improve the air flow and heating capacity by improving the agitation airflow of the air, and greatly improve the temperature uniformity of the test chamber.
 

Control System

 

Projectillustrate
Controller7-inch PLC LCD touch programmable controller
Touch high-definition screenThe fixed conditions and program conditions can be set arbitrarily, the Chinese screen can be set, and the curing test name and serial number can be set.
Settable time range0—999H59min.

Programmable mode

 

At the same time, 120 groups of programs with different conditions can be set. In any group of programs, the work can be divided into 1200 segments, and the number of segments can be arbitrarily intercepted to execute the cycle, or the periodic cycle of any segment or group can be performed.
In each group of programs, up to 1200 different temperature and time sections can be set (each section can be set up to 999h59min). 120 groups of programs can be connected in series at will, and the maximum number of sections can be cycled up to 999 times.
SafetyWith a power-off memory device, the remaining programs can continue to be executed when the power is restored, and the machine can be reserved to execute the start-up and machine running time.
ControlRising and cooling can be used for slope control and curve control, and has the function of self-correcting temperature and humidity reference points. It has the function of PID automatic calculation, which can reduce the convenience brought by manual setting.
Communication functionU disk interface, RS-232 interface, mis operation hardware lock, random computer communication software
Set upTouch setting, direct display of position, all conditions are completely automatically locked by microcomputer
Call the policeIf there is an error in the setting or operation, a warning signal will be provided
OutputThe controller has a recording signal port output, which can be connected to a temperature and humidity recorder and output a recording curve
InterfaceWith standard RS-232 communication interface, long transmission distance, can be connected to PC for control and recording.
 

Safety Protection Device

 

Cooling System

Compressor overheating protection

Compressor overcurrent protection

Compressor high and low pressure protection

Compressor oil pressure protection

Liquid temperature over-temperature protection

Ultra-high pressure relief protection

Air-cooled: the condensing fan is overheated

Test box

Adjustable over temperature protection

Air conditioning channel extreme over temperature protection

Fan motor overheating protection

Other

Total power phase sequence and phase loss protection (applicable to three-phase power supply)

Overload and short circuit protection

Refrigeration system failure alarm protection caused by multiple openings of the box

Other configuration
Power cableAC380V power supply: 1 five-core (three-phase four-wire + protective ground wire) cable (about 4 meters long)
Main power switchChint Circuit Breaker
TransportationThe test box is combined and transported separately
SizeMaximum Shipping Dimensions (without packaging): "See Dimensions"
weightMaximum shipping weight (without packaging): "See Weight"
Conditions of UseThe following conditions are guaranteed by the user
Installation site

1. The ground is flat and well ventilated

2. No strong vibration around the device

3. There is no strong electromagnetic field around the device

4. There is no flammable, explosive, corrosive substances and dust around the equipment

5. Appropriate space for use and maintenance should be reserved around the equipment, as shown in the following figure:

 

A: ≥40cm

 

B: ≥150cm

 

C: ≥100cm

 

D: ≥60cm

 

E: ≥40cm

Environmental conditions

1. Temperature: 5℃~35℃

2. Relative humidity: ≤85%

3. Air pressure: 86kPa~106kPa

Power supply conditions

AC380V power supply requirements:

1. Three-phase four-wire + protective ground wire

2. Voltage range: AC (380±38) V

3. Frequency fluctuation range: (50±0.5) Hz

4. The grounding resistance of the protective ground wire is less than 4Ω

5. The user is required to configure an air or power switch of the corresponding capacity for the equipment at the installation site, and this switch must be used independently for the equipment

Power supply

Imax≤32A

Pmax≤15KW

Maximum currentOpening the door of the test box during the test will cause the temperature and humidity in the box to fluctuate; if the door is opened multiple times or for a long time or the test sample emits moisture during the test, it may cause the heat exchanger of the refrigeration system to freeze instead of working properly.
 

Configuration

 

No.NameModelRemark
1Equipment boxInner SUS 304 stainless steelFeng Qianyuan
2sensorArmoured, PT100, Class ABeijing "Sai Yiling"
3AC contactorOptionalSchneider
4thermal relayOptionalSchneider
5Over temperature protection control instrumentWMK-102L(0_399)Domestic high quality
6Intermediate relayOptionalSchneider
7Circulation fan90W/220VJoint venture "Zibang"
8Programmable ControllersTH2200-ASonghua
9temperature moduleSonghua
10Touch screen (color screen)Songhua
11Leakage switch380V63AChint
12control transformerBK-300Chint
13breaker3P60ASchneider
14solid state relay40ATaiwan "Yang Ming"
15heaterNichrome wireDomestic high quality
16compressorOptionalGerman "Bitzer"
17Evaporatorcustom madeTaiwan Zhongli
18The refrigerantR404A/R23DuPont USA
19Frozen oilRL32HBritish ice bear
20oil separatorLarge system supporting 55824/55855Emerson (formerly ALCO, USA)
21Gas-liquid separatorLarge system supporting 3/8″, 1/2″Fuzhou, Taiwan
23filter drierDCL032/053/083/085Danfoss Denmark or Sporland USA
24The electromagnetic valve3/8 or 5/8Sagittarius or Kasto in Japan
25EvaporatorCustomJoint venture
26Copper miscellaneous partsOptionalTaiwan Xiongde
 

Product features and advantages

 

  1. Energy saving: The technology is based on the PWM solenoid valve customized by Sporlan Company in the United States. This technology realizes the regulation of the pipeline flow through the frequent actions of the solenoid valve. The standard solenoid valve cannot adapt to it, and it will cause fatigue damage in a short time. Currently, this technology is supported. The main performance valve is only produced by Sporlan Company in the United States. The following picture shows the difference between the solenoid valves.

PWM Valve Normal Valve

  1. Performance: The equipment conforms to the latest standards, the equipment is integral, beautiful and easy to transport; The main parts of the equipment are selected from well-known brands at home and abroad. The fully enclosed and imported French "" compressor with higher precision and the Hangzhou "Yuanfang" variable frequency power supply with better stability make the precision control more accurate during the operation of the equipment. Noise Lower, more stable performance and longer service life;
  2. Device control: The device can be connected to multiple devices, controlled by mobile phone APP, and controlled by advanced PLC, which is more intelligent and more convenient to operate. The true color touch screen displays various test data (temperature, time, test curve), which is easier to operate. observation records;
  3. Measurement and control system: real-time and dynamic display of test process and test curve, data processing through modular software, data reanalysis and editing of curve amplification, output of test reports and curve patterns in different formats, and support for networked data transmission.
  4. Professional, safe and user-friendly design: emergency stop control switch, in case of emergency, can lock equipment reliably; effectively protect equipment; multiple protection of software and hardware to ensure the safety of equipment and personnel.

 

 

Hot Products

IEC62196 Electric Vehicle Power Supply Plugs And Sockets Rolling Test Equipment Complied Standards & ...
IEC62196 Electric Vehicle Charging Plug and Socket Withdrawal Insertion Force Test Equipment ...
IEC 60390 Electric Vehicle Charging Plug And Socket Cable Flexing Test Apparatus Complied Standards ...
IEC62196 Electric Vehicle Plugs And Connectors Steel Ball Impact Device Complied Standards & Clauses ...
IEC 62196 Electric Vehicle Connector And Plug Universal Material Tensile Machine Complied Standards ...
IEC62196 New Energy Vehicle Multiple Portable Socket-Outlets Mechanical Strength Tester Complied ...