Home Companies Sinuo Testing Equipment Co. , Limited

DIN 75220 Electric Vehicle Solar Simulation Test Chamber Halogen Lamp Test Chamber

Sinuo Testing Equipment Co. , Limited

Contact Us

[China] country

Trade Verify

Address: Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone, Shibi Street, Panyu District, Guangzhou, China

Contact name:Zoe Zou

Inquir Now

Sinuo Testing Equipment Co. , Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

DIN 75220 Electric Vehicle Solar Simulation Test Chamber Halogen Lamp Test Chamber

Country/Region china
City & Province guangzhou guangdong
Categories Temperature Instruments
InquireNow

Product Details

 

 

DIN 75220 Electric Vehicle Solar Radiation Halogen Lamp Test Chamber

 

Complied Standards & Clauses


 

DIN 75220: “Ageing Automobile Components in Solar Simulation Units”

ISO9060:2007 “Solar energy-Specification and classification of instruments for measuring hemispherical solar and direct solar radiation

ISO 12097-2: "Road vehicles-Airbag components-Part 2: Testing Of airbag modules"

 

Technical Parameters


Working Dimensions: D×W×H2500×2500×2500MM
External Dimensions: D×W×H4100X3100X3000MM
Power (kw)13KW
PerformanceTemperature RangeWorking room temperature: -30 ℃ ~ 85 ℃ (dark cycle)
Humidity Range1. Lighting cycle: 10 ~ 60% RH
2. Humidity range of dark cycle: up to 100%
3. Humidity accuracy: ≤ ± 5%
Spectral Wavelength290-2450nm optional
Lamp Radiation Intensity1050W/m2 accuracy≦±0.01W/m2
Lamp Tube Power2.5KW (Air-cooled full solar spectrum metal halogen lamp) X 4
Lamp Total Power10KW, lifespan:1000 hours
Blackboard TemperatureBST control range: 80 ℃ (adjustable)
BPT control range: 80 ℃ (adjustable)
Distance from Arc Center to Sample1200mm, effective exposure area ≥ 3000cm2
 Sample Rack1200X1200MM
 Accuracy RangeSetting / indication accuracy: temperature 0.1 ℃, humidity 1% RH
Temperature and Humidity SensorPlatinum resistance.PT100Ω / MV
Heating SystemFully independent system, nickel-chromium alloy electric heater
Humidification SystemExternal isolation type, all stainless steel shallow surface evaporative humidifier
Blackboard TemperatureBimetallic blackboard thermometer
Temperature ControllerAdopt Siemens color touch screen and German Siemens PLC module control
Circulatory SystemTemperature-resistant and low-noise air-conditioning motor. Multi-blade centrifugal wind wheel
MaterialOuter Chamber MaterialHigh quality carbon steel plate, phosphating electrostatic spray treatment / SUS304 stainless steel matte line hairline treatment
Inner Chamber MaterialSUS304 high-quality stainless-steel smooth plate
Sample Rack MaterialSUS304 high-quality stainless-steel bar 
Door Frame Insulation

High and low temperature aging silicone rubber door sealing strip

 

 
Number of Sample RacksThe number of samples is 16, according to the blackboard temperature and irradiation sensor 
Sun EyeIntelligent irradiation induction loop system with German chip. Automatically correct the setting value of irradiation intensity. It is high temperature and high humidity resistance; shell is made of 304 material. 
Standard Configuration1 set of anti-radiation glass windows, 4 lamps 
Safety ProtectionProtection of electric leakage, short circuit, over temperature, water shortage, motor overheat, over current 
Power SupplyAC380V±10% 50±0.5Hz three-phase five-wire system 
Use Ambient Temperature5℃~+30℃ ≤85%RH

 

Equipment Overview


 

Lighting System

The system is composed of intelligent control power supply, optimized design of reflector lamp housing, Osram 2500W metal halogen lamps, cabinet, illuminance meter, etc. It can perfectly simulate the sunlight irradiation environment under various conditions. Coupled with environmental factors such as temperature, humidity, rain, and snow, it is used to evaluate the impact of direct solar radiation on the test specimen (thermal, mechanical, chemical, electrical, etc.), and can also be used to reveal the mutual interaction between different materials in the component effect. The sunlight simulation system can be used alone for testing of electronics, materials, and small-volume test pieces. Multiple sets of systems can also be combined into a light array through professional design and layout, which is used for the test of cars, trucks, photovoltaic modules, even trains and airplanes.

 

Intelligent power supply (EPS):

 

 

1) The power module uses a high-performance MCU as the control core, and the high-precision vector control algorithm ensures a stable output of energy, so that the brightness of the lamp is fixed and is not affected by the input grid voltage and cooling.

 

2) It can realize 20% to 100% output stepless adjustment, the overall heat dissipation is small, and it has multiple control and communication methods.

 

DisplayOperation interface displayRun statusCan monitor output voltage and output current, set temperature power and module temperature, etc.
Parameters settingRelevant parameter values can be flexibly set according to actual requirements
Protection / Alarm functionsOvercurrent, overvoltage, undervoltage, overheat, short circuit, internal storage failure, etc.
SurroundingsAmbient temperature-10℃ to +50℃ (No freeze)
Ambient humidityLess than 90% (No frost)
Surrounding environmentIndoor (No direct sunlight, no corrosion, no flammable gas, no oil mist, no dust, etc.)
AltitudeLess than 1000m

 

3) The power supply control can monitor the status of the lamp in real time during the lighting process and make corresponding warnings. If the lighting is unsuccessful, it will stop the lighting and give an alarm prompt when it exceeds a certain delay, avoiding the dangerous situation of unsuccessful lighting for a long time to maintain high voltage.

 

Cabinet:

 

Modular power supply design, with the overall cabinet, with advantages of small footprint, neat lines, convenient connection; power supply can be placed in the overall cabinet for unified control, provide corresponding communication interface protocol into the test box control system, and use the touch screen for system local control and operation, control accuracy: ≤5%.

 

Sunlight simulation:

A total of 98 sets of light sources, each set of light sources is equipped with an EPS control power supply, which can control the power supply of each light source separately.

 

 

Full spectrum: +/- 10%, within a height of 1m.
After simulation, the simulation uniformity of lighting simulation is about ± 5%, better than the requirement of ± 10.
For details, see following figure of the simulation calculation:

 

Control System:

 

The lighting simulation system adopts closed-loop control mode, equipped with KIPP & ZONEN SMP10 high-sensitivity lighting sensor that meets ISO 9060 two-level standard. Through this sensor, the light intensity of the measured surface is collected in real time. The control system automatically adjusts the energy output according to the deviation between the set value and the collected value, to ensure the stability of the light throughout the test.

 

Advantages:

 

Wide operating environment

Since there are no starter lamp electronic components in the reflector of the lighting system, the system has very wide temperature and humidity operating range (temperature range is -100 ℃ -200 ℃, humidity range is 0-98%).

 

High security

Because the lighter is installed in the intelligent power supply, the intelligent power supply can monitor the working voltage and current of the metal halide lamp in real time., to ensure that the power supply is automatically stopped when the lamp is turned off and the lamp is not excited, and the alarm information is given. In addition, the device does not need to be discharged after use, to avoid negligent operation of high voltage electric shock.

Comes with BUCK voltage regulator circuit and power vector control algorithm to control the output, effectively avoiding the phenomenon of light extinction caused by grid fluctuations. With fault alarm and automatic protection, there is no voltage at the output end when the light is off.

 

Good stability

Comes with BUCK voltage regulator circuit, which can work at AC340V ~ 440V; The control system is controlled by power vector control algorithm to ensure the output power is constant and adjustable; with automatic compensation functions such as air extraction compensation, real-time monitoring of abnormalities and automatic adjustment, regardless of voltage fluctuations and ambient temperature fluctuations, the output energy is still constant; comprehensive safety protection: lamp parameter error protection, lamp disconnection protection, lamp short circuit protection, etc.; using German Siemens IGBT, Japanese magnetic core, American MCU. (Can work at 100 ℃); all equipment has passed 100% functional testing and aging process testing.

 

Wide adjustment range

Microcomputer control, with automatic compensation functions such as ventilation compensation, real-time monitoring of abnormalities and automatic adjustment, so that the system has the ability to adjust from 10% -100% energy stepless. With linear control and square wave output, the highest efficiency is achieved, regardless of voltage fluctuations and ambient temperature fluctuations, the output energy is still constant.

 

1. Sunlight simulation system

This test system consists of a total of 98 sunlight simulation units (14 × 7). Each sunlight simulation unit has the same power and is 4KW. The specific distribution is as follows:

 

Spectral regionBandwidth
(nm)

Radiation

(% of total)

Tolerance

Min

Tolerance

Max

Irradiance
(W/m²)
Spectral region
Irradiance (W/m²)
UVB280 to 3200.50.30.75.65.6
UVA320 to 3602.41.8326.962.7
360 to 4003.22.44.435.8
VIS400 to 52017.916.119.7200.5580.2
520 to 64016.614.918.3185.9
640 to 80017.312.819193.8
IR800 to 300042.133.750.5471.5471.5
Total11201120

 

 

2. Effective area of irradiation:  1500×1500mm

 

3. Irradiation distance:  1200mm (fixed)

 

4. Average irradiation intensity:  1050W / m2

(Continuously adjustable within 600-1200W / m2, the modulation accuracy is not greater than 50W / m2. Can be used for low-irradiation experiments of 200W / m2. Due to the EPS is infinitely adjustable within the range of 50% -100%, for experiment of low-irradiation of 200W , the grating should be increased, and the radiation intensity controlled through the transmission rate of the grating (60%, 80% two specifications), so that the light intensity can reach 200W / m2).

 

5. Light support

The lamp support is made of industrial aluminum profiles.

Lampshade is made of aluminum magnesium alloy.

There are 4 sets of lamp stands installed on the lamp support. The lamp stands are divided into 2 horizontal rows, 4 lamp tubes in each row, and each bulb is 2500W. The distance between the front, back, left, and right of the lamp tube is 1200MM, and each light bulb has an independent switch control. The layout of the light bulb is shown in the figures. The power adjustment range of the lamp is stepless adjustment within the range of 10% to 100%, the total power of the lamp is 10KW.

 

 

 

6. Light intensity sensor

Three light intensity sensors are used to measure radiant power in W / m².
The light intensity sensor is resistant to high temperatures and can be installed on the vehicle throughout the test procedure.
The light intensity sensor is equipped with a high-temperature-resistant 10 m long connecting cable.
The light intensity sensor is connected and disconnected in the junction box.

 

The metal halide lamp intensity can be adjusted to 50% by EPS. If a low-irradiation test is required, it can be achieved by turning off the light source.

1120 W/m²      electrically dimming       all lamps ON
1040 W/m²      electrically dimming       all lamps ON
915 W/m²       electrically dimming       all lamps ON
730 W/m²       electrically dimming       all lamps ON
          505 W/m²        electrically dimming       half of the lamps ON
          270 W/m²        electrically dimming       half of the lamps ON

55 W/m² Not possible

Uniformity
In the range of 600-1200W / m², the uniformity within the effective irradiation area is less than 10%. When the low-irradiation test is performed, uniformity requirements are not required. The uniformity test method: divide the effective irradiation area 4000x6000mm into 384 squares , the area of each square is 250x250mm, place the radiometer in the center of each square.

 

7. Lighting control mode

Automatic control through the light intensity feedback, also can be manually adjusted to the required intensity, and has the function of alarm / stop when the measured parameter value exceeds the limit.

 

 

8. Technical data

System operating temperature range: -20 ° C to + 60 ° C
System storage temperature range: -40 ° C to + 60 ° C
Irradiation area: 1200 mm x5000 mm
Irradiation power: 1200 W / m² maximum on the reference plane
Irradiation distance: The bulb is adjustable from 200-1200mm from the reference plane.
Irradiation intensity control: 10% ~ 100%
Uniformity: the reference surface is ± 10%
Light intensity sensor: a total of 1 set

Equipped with a computer (industrial computer)

 

Chamber Design Drawings

 

Questions & Answers


 

Q: What temperature can this device reach?
A: The system operating temperature range: -20 ° C to + 60 ° C
System storage temperature range: -40 ° C to + 60 ° C.

 

Q: What is the size for Irradiation area?
A: The
Irradiation area of the equipment is 1200 mm x5000 mm
.

 

Hot Products

IEC62196 Electric Vehicle Power Supply Plugs And Sockets Rolling Test Equipment Complied Standards & ...
IEC62196 Electric Vehicle Charging Plug and Socket Withdrawal Insertion Force Test Equipment ...
IEC 60390 Electric Vehicle Charging Plug And Socket Cable Flexing Test Apparatus Complied Standards ...
IEC62196 Electric Vehicle Plugs And Connectors Steel Ball Impact Device Complied Standards & Clauses ...
IEC 62196 Electric Vehicle Connector And Plug Universal Material Tensile Machine Complied Standards ...
IEC62196 New Energy Vehicle Multiple Portable Socket-Outlets Mechanical Strength Tester Complied ...