Product Details

 

Description

 

The cabinet is one compartment, double-wall cabinet. The cabinet cooling uses AC air conditioner and fans, to ensure the equipments operate normally at stable temperature range, so as to make the service life of the equipments much longer and their performance more stable.

 

Technical Parameters

 

Item

  Type 

 Technical Parameter

Structure

Dimension

External Dimension: H*W*D 1650*800*1000mm

Internal Dimension: H*W*D 1350*740*950mm

Layout 

1 compartment 

Equipment Installation Method

19” rack

Door 

With one front door and one back door, and special lock for outdoor cabinet (support padlock) 

Material 

Galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate

Heat Insulation

There are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF.

Structure 

Welded

Ingress Protection

IP55

Temperature Control

Cooling 

AC220V air conditioner and DC48V fans 

Lightning Proof

Grade B lightning proof 

Nominal: 60KA, Max.: 100KA

Lighting

LED lamp

48V LED lamps (immovable), with protective circuit breaker 

Temperature 

Temperature

Working Temperature: -40°C ~ +55°C

Storage Temperature: -50°C ~ + 70°C

Transport Temperature: -50°C ~ +70°C

Humidity

Relative Humidity

5% ~ 100%

Pressure

Air Pressure 

62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)

Radiation Intensity 

Solar Radiation Intensity

1120 ×(1±5%)W/m2

 

Accessories List

 

No. 

Item

Quantity

Unit 

Specs

1

Outdoor Telecom Cabinet

1

Set 

(1) External Dimension:                   H*W*D 1650*800*1000mm;                             Internal Dimension:                     H*W*D 1350*740*950mm.                  (2) 1 compartment;                               (3) With one front door and one back door, and special lock for outdoor cabinet (support padlock) ;                                        (4) Material: galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate;              (5) Welded.

2

Air Conditioner

1

Set

Cooling capacity: 1.5KW, AC220V, 50HZ

3

110V to 220V Transformer 

1

Set

110V to 220V transformer, 1000W

4

Water Sensor

1

PC

 

5

Smoke Sensor

1

PC

 

6

Environment Monitoring Unit

1

Set

2U

7

UPS

1

Set

Model: D3K

8

Temperature and Humidity Sensor

1

PC

 

9

Power Distribution Unit

1

Set

Lightning proof: single phase, nominal 60KA, Max. 100KA;

AC Input:: 63A/2P*1;

AC Output: 20A/1P*2;

Maintenance Socket: single phase, three holes *1 

10

LED Lamps

2

PC 

DC48V

11

Auxiliary Direct Ventilation Fans

2

PC

12038 DC48V

12

Lead Acid Battery

4

SET

12V 150AH

13

Door Sensor

4

PC

Control LED lamps

14

LED lamp Circuit Board

2

PC

 

15

PDU

1

Set 

Remotely Manageable PDU, Model: NP-16R

16

Package

1

Set 

Wooden Case

 

Lead Acid Battery Specs

 

Model

Rated Voltage

Capacity

(AH)

Weight

Terminal Specs

Dimension(mm)

Internal Resistance

Short Circuit Current

Terminal Position

(V)

(Kg)

(L*W*H)

(mΩ@25°C)

(A)

RA12-150

12

150

44.5

F5/F12

483*170* 240(240)

4.3

2700

C

 

UPS Specs

 

 

 

 

Techinical Parameters

                 

      Model

D3K

Rated Output Capacity

3000VA/2400W

AC Input

Input Mode

Single Phase Grouding

Rated Voltage

100/110/120Vac

Rated Frequency

50Hz

Input Voltage Range

80~ 145VAC±5

Input Frequency Range

(45~55) ± 0.5Hz

Bypass Voltage

80VAC×(1± 5%) ~ 145VAC×(1± 5%)

 

Battery Input

Battery String Voltage

96VDC; Optional (48V, 72V)

Battery Number

8; Optional (4,6)

Backup Time (Half/Full)

Half load ≥10 minutes, Full load ≥5 minutes (standard type)

Power On Input Max. Impulse Current

< 150% of Rated Current

Battery Charge Time

Charge to 90% within 5 hours (standard type)

 

AC Output

Output Mode

Single Phase Grouding

Output Voltage

100/110/120Vac ± 3% (Inverting Output)

Output Frequency

50 ± 5Hz ( When the AC input is normal)

50Hz ± 1% ( When the AC input is abnormal)

Dynamic Voltage Transient

< 5%

Dynamic Transient Recovery Time

< 60ms

Waveform

Sine WaveTHD < 3% (linear load)

Sine WaveTHD < 8% (nonlinear load)

Output Power Factor

0.8

Overload Capability

130% load lasts for not less than 30s, recovery point is 90% load.

Output Current Peak Factor

3:1

Inverting to Bypass Time

<4ms

 

Communication and Monitoring Function

RS232 ( can be turned to RS485), dry contact, intelligent socket (can expand multiple monitoring mode such as SNMP, mobile phone text massage etc.)

Audio Noise

< 55dB (1m)

Weight (kg)

28

Dimension (W*D*H mm)

190*318*433

 

Cabinet Layout Diagram

 

 

Fans Cooling Diagram

 

Air Conditioner Cooling Diagram

 

 

 

Hot Products

Power System of High Performance and High Reliability GPH48300A Integrated Power System Input:90...
Two Bay Stainless Steel Temperature Control Outdoor Battery Cabinet With Anti-smoke Anti-corrosion ...
Stainless steel Temperature Control Outdoor Battery Cabinet With 3 Layer Battery For Telecom Station ...
ET8080150AL-BA Aluminum Outdoor Battery Cabinet 1. Application Outdoor Battery Cabinet offer a ...
Waterproof Double Wall Galvanized Steel Outdoor Battery Cabinet / IP55 Base Station Cabinet Brief ...
Air Conditioner Integrated Galvanized Steel Outdoor Battery Cabinet With Three Battery Layers 1. ...