Home Companies WENZHOU QIUPU ELECTRIC POWER CO., LTD.

Casting Resin Indoor High Voltage Current Transformer Single Phase / 3 Phase

WENZHOU QIUPU ELECTRIC POWER CO., LTD.

Contact Us

[China] country

Trade Verify

Address: ROOM 302 , BUILDING 65 , ZHENGDA CITY , NO. 555 YANHAI WEST ROAD , CHENGNAN STREET , YUEQING CITY , ZHEJIANG, PROVINCE . CHINA-325600

Contact name:Cheng

Inquir Now

WENZHOU QIUPU ELECTRIC POWER CO., LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Casting Resin Indoor High Voltage Current Transformer Single Phase / 3 Phase

Country/Region china
City & Province zhejiang
InquireNow

Product Details

LZZBJ9-35 Casting Resin Indoor High Voltage Current Transformer

 

 

The primary coil is in series in the circuit, and the number of turns is very small. Therefore, the current in the primary coil depends entirely on the load current of the circuit being tested, but not on the secondary current;
The current coil impedance of the current Transformer secondary coil and the relay are very small, so under normal circumstances, the current Transformer is running near short circuit.
The ratio of the first and second rated current to the current Transformer, called the rated mutual inductance ratio: kn = I1n / I2n
Since primary coil rated current I1n has been standardized and secondary coil rated current I2n has been unified to 5(1 or 0.5) Ann, the rated mutual inductance ratio of current Transformer has also been standardized. Kn can also be expressed roughly as the turn ratio of the first and secondary coils of the transformer, i.e. the turn ratio of N1. N2 to the first and second coils in the Kn _ kN = N1/N2.

There are two kinds of transformer, voltage Transformer and current Transformer. Voltage transformer can be used for measuring voltage and power in high-voltage and high-voltage power systems. The current Transformer can be used for the measurement of exchange current, the measurement of exchange voltage and the protection of power drag lines.
Voltage transformer


By purpose


Measurement winding of voltage Transformer or voltage transformer for measuring: To provide grid voltage information to measuring device within normal voltage range;
Protection winding of voltage Transformer or voltage transformer for protection: In the state of power grid failure, provide information on power grid failure voltage to relay protection devices.

 

 

Ratedprimary CurrentAccuracy classInsulation Level
20-2500A0.2/0.240.5/95/200kV
   

        

Hot Products

Bus Bar Insulators With Brass Screw, Sm Sb Type Bus Bar Insulator Busbar Insulator 1. We are ...
Best Quality Epoxy Resin Insulator SM Series Bus Bar Insulator For Switchgear 1. The BMC(DMC) ...
Wholesale 10-35KV Cabinet Indoor, High Voltage Epoxy Resin Insulator High Red Epoxy Resin Insulator ...
Low Voltage Electrical Epoxy Resin Standoff Support Insulator Of Busbar Product Description: ...
Epoxy Resin Insulation Support EL-24 70X210 24KV Busbar High Voltage Standoff Insulator Product ...
Electrical Epoxy Resin Bus Bar Insulator Sm76 - Sm25 Porcelain Insulators​ Product Description: ...