Home Companies WENZHOU QIUPU ELECTRIC POWER CO., LTD.

Polymeric Metal Oxide Gapless Lightning Arrester For Electrical Substation 11kV

WENZHOU QIUPU ELECTRIC POWER CO., LTD.

Contact Us

[China] country

Trade Verify

Address: ROOM 302 , BUILDING 65 , ZHENGDA CITY , NO. 555 YANHAI WEST ROAD , CHENGNAN STREET , YUEQING CITY , ZHEJIANG, PROVINCE . CHINA-325600

Contact name:Cheng

Inquir Now

WENZHOU QIUPU ELECTRIC POWER CO., LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Polymeric Metal Oxide Gapless Lightning Arrester For Electrical Substation 11kV

Country/Region china
City & Province zhejiang
Categories Lightning Rod
InquireNow

Product Details

    HY5W-11/36 Zinc Oxide Arrester with Electrical Switchgear Euipment

 

 

Specification:

     

Rated VoltageWork VoltageAC Current
11KV36kV10A
   

   

 

    At the same time, this value should be compared with the manufacturer's specified value, the change should not be greater than 5 %. If the MOA is too low, it may explode under the transient overvoltage of various operations and faults. If the surface of the MOA ceramic cover is seriously damped, the measurement value will also be affected, so the surface leakage should be eliminated during the test. Measurement of alternating current leakage of operating voltage. The test is to measure the total current, resistance current and power loss.

 

If the total current value is measured to be more than 20 % higher than the initial value, or to exceed the manufacturer's specified value, it should cause immediate concern and strengthen the operation monitoring. If the total current value is measured to be more than 50 % higher than the initial value, the operation should be eliminated.

 

If the measured resistance current more than double the factory's specified value, should also be out of operation, until the reason for removal or replacement, but can not take the fault operation. In conducting the above-mentioned tests on MOA, the current ambient temperature, relative humidity and operating voltage should be recorded, and the effects of the related interference should be noted and eliminated in the tests.

Hot Products

Bus Bar Insulators With Brass Screw, Sm Sb Type Bus Bar Insulator Busbar Insulator 1. We are ...
Best Quality Epoxy Resin Insulator SM Series Bus Bar Insulator For Switchgear 1. The BMC(DMC) ...
Wholesale 10-35KV Cabinet Indoor, High Voltage Epoxy Resin Insulator High Red Epoxy Resin Insulator ...
Low Voltage Electrical Epoxy Resin Standoff Support Insulator Of Busbar Product Description: ...
Epoxy Resin Insulation Support EL-24 70X210 24KV Busbar High Voltage Standoff Insulator Product ...
Electrical Epoxy Resin Bus Bar Insulator Sm76 - Sm25 Porcelain Insulators​ Product Description: ...