Home Companies Hontai Machinery and equipment (HK) Co. ltd

4WE-10 Series-Solenoid Operated Directional Valves Directional control valves

Hontai Machinery and equipment (HK) Co. ltd

Contact Us

[China] country

Trade Verify

Address: 27P , Block B , Duhui 100 , Zhonghang Road , Futian District , Shenzhen , China

Contact name:Biona

Inquir Now

Hontai Machinery and equipment (HK) Co. ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

4WE-10 Series-Solenoid Operated Directional Valves Directional control valves

Country/Region china
City & Province shenzhen guangdong
Categories Valves
InquireNow

Product Details

                4WE-10 Series-Solenoid Operated Directional Valves Directional control valves

 

CHARACTERISTICS
  • Direct operated, solenoid actuated directional spool valve high performance version.
  • Porting pattem to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H
  • Wet pin AC or DC solenoids with removable coil.
  • Solenoid coil can be rotated through 90o
  • Coils can be replaced without releasing any fluid.
  • Choice of either certral or indevidual lelctrical connections.
  • Optional hand emergency.
HOW TO ORDER

FUNCTIONAL DESCRIPTION
  • Type WE diectional control valves are solenoid operated directional spool valves. Thery control the start, stop and direction of flow.
  • Essentially the directional control valves consist of housing (1), one or two solenoids (2), the control spool (3), and one or two retum springs (4).
  • In the de-energised condition the control spool (3) is held in the neutral or initial position by means of retum springs (4) (except for impulse spool). The control spool (3) is operated by wet pin solenoids (2).
  • To guarantee satisfactory operation care shoud be taken to ensure that the solenold pressure chamber is filled with oil.
  • The force of the solenoid (2) acts via the plunger (5) on the control spool (3) and pushes this from its neutral position to the required end position. The gives free flow from P to A and B to T or P to B and A to T.
  • When solenold (2) is de-energised, the control spool (3) is retumed to its neutral position by means of retum springs (4).
  • An optional hand emergercy (5) allows movement of the control spool (3) without energising the solenoid.

Hot Products

CR - M012DC2 pluggable interface Electrical Relay , ABB CR - M miniature relay The pluggable ...
CR-S Range The slim line of interface relays and optocouplers The pluggable interface relays and ...
CR-P range The pluggable pcb interface relays The pluggable interface relays of the CR-P range are ...
The TZIDC represents the digital, intelligent positioner for communication via HART within the ...
AF09 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are ...
The TZIDC represents the digital, intelligent positioner for communication via HART within the ...