CJX2(LC1-D09) Series AC Contactors |
Application |
CJX2(LC1-D09) series A.C.contactor are suitable for frequency
50/60Hz, rated insulation voltage up to 1000V, rated operation current 9~330A under AC-3duty. It is
mainly used for making/breaking electric circuits at along distance & for frequent
starting/stopping & controlling A.C.Motors. It is used in combination with thermal relay to compose a magnetic motor
starter, so. The products accords with such standards as IEC60947-4-1 & GB14048.4. |
Technical parameter |
Rated operational voltage & rated insulation voltage of the
contactor see table1. |
Model | Rated operating voltage(V) | Rated operating voltage(V) | CJX2-9~95 | 220~660 | 220~1000 | CJX2-115~330 | 660 | 1000 |
|
Conventional thermal current and rated operating current and
maximum power of controllable 3-phase |
A.C.motor under AC-3 duty see Table 2. |
Model | Conventional thermal current(A) | Rated operating voltage(V) | Rated operating voltage(V) | 380V | 660V | 1000V | 380V | 660V | 1000V | CXJ2-9 | 20 | 9 | 6.6 | | 4 | 5.5 | | CXJ2-12 | 20 | 12 | 8.9 | | 5.5 | 7.5 | | CXJ2-18 | 32 | 16 | 10.6 | | 7.5 | 9 | | CXJ2-25 | 40 | 25 | 18 | | 11 | 15 | | CXJ2-32 | 50 | 32 | 21 | | 15 | 18.5 | | CXJ2-40 | 60 | 40 | 34 | | 18.5 | 30 | | CXJ2-50 | 80 | 50 | 39 | | 22 | 33 | | CXJ2-65 | 80 | 65 | 42 | | 30 | 37 | | CXJ2-80 | 125 | 80 | 49 | | 37 | 45 | | CXJ2-95 | 125 | 95 | 49 | | 45 | 45 | | CXJ2-115 | 200 | 115 | 65 | 40 | 55 | 80 | 65 | CXJ2-150 | 200 | 150 | 80 | 50 | 75 | 100 | 65 | CXJ2-185 | 275 | 185 | 95 | 65 | 90 | 110 | 100 | CXJ2-225 | 275 | 225 | 115 | 80 | 110 | 129 | 100 | CXJ2-265 | 315 | 265 | 150 | 95 | 132 | 160 | 147 | CXJ2-330 | 380 | 330 | 185 | 115 | 160 | 220 | 160 |
|
Endurance is shown in table 3. |
Model | Frequency of operation(1/h) | Frequency of operation(1/h) | Frequency of operation(1/h) | CJX2-9~25 | 1200 | 1200 | 100 | CJX2-32~40 | 600 | 800 | 80 | CJX2-50~65 | 60 | CJX2-80~95 | 600 | CJX2-115~150 | 1000 | 120 | CJX2-185~225 | 600 | 100 | CJX2-265~330 | 80 |
|
Voltage range of control coil:(0.85-1.1)US |
Technical date of the auxiliary contacts see table 4. |
Utilization category | AC-15 | | AC-15 | Rated insulation voltage(V) | | 660 | | Rated operating voltage(V) | 380 | | 220 | Conventional thermal current(A) | | 10 | | Rated operating current(A) | 0.95 | | 0.15 | Contarol capacity | 360VA | | 33W |
|
Voltage of control coil power see Table 5 |
Model | Control Voltage(V) | Control capacity | Staring(VA) | Attracting(VA) | CJX2-9~18 | 24,36,48,110,127,220,380 | 60 | 7 | CJX2-25~32 | 90 | 7.5 | CJX2-40~95 | 200 | 20 | CJX2-115~150 | 110,127,220,380 | 660 | 54 | CJX2-185~225 | 966 | 66 | CJX2-265 | 110,127 | 7200 | 10 | CJX2-330 | 220,380 | 840 | 12 |
|