Paper / Textile industry Chemical Centrifugal Pump 1450 r/min
IHF-type fluorine centrifugal pump ┃ fluorine plastic centrifugal
pump start, run and stop:
- IHF centrifugal pump should be filled before filling the pump
filled with the delivery of liquid, no liquid start.
- Close the outlet valve, turn on the power immediately after
checking the pump steering must be the same as the pump steering
arrows, is strictly prohibited reverse operation.
- IHF centrifugal pump to reach the normal speed after starting, and
then gradually open the outlet valve, and adjust to the required
conditions put into operation. The pump can not work for more than
3 minutes while the valve is closed on the discharge line.
- Shut down the valve should first be closed, and then cut off the
power.
IHF-type fluorine centrifugal pump ┃ fluorine plastic centrifugal
pump repair and maintenance:
- Check the pump and motor regularly and replace the consumable
parts.
- Always pay attention to the bearing box filling high-quality
calcium-based grease to ensure a good bearing lubrication state.
- Long-term downtime is not used, in addition to the pump corrosive
liquid put the net, but also pay attention to the parts and pump
flow channel cleaning, and cut off the power.
- The pump does not allow no-load operation.
- If the solid particles in the medium, should be added to the pump inlet filter.