Qingdao AIP Intelligent Instrument Co., Ltd |
|
Safety Testing System For Home Appliance With Variable Speed
1. Test object: safety testing system applies to all kinds of home appliance,
production line, and laboratory.
2. Feature
Power test for products with variable speed: such as electric fan
and soybean milk machine. The product needs to be tested at
different speed and the testing system will give the test result
automatically.
The safety testing system equipped with standard PLC remote
control, RS232 and alarm light port.
3. Technical parameters
Test items | AC Hipot, DC Hipot, Insulation resistance, Grounding resistance, leakage current, power |
Data save mode | USB save |
AC Hipot | |
Output voltage setting range/ precision | AC 200~5000V ±(3%×setting value+5 words) |
Breakdown current testing range/ precision | 0.10~25.00mA ±(3%×display value+5 words) |
Breakdown current presetting alarm range | Max:0.10~25.00mA ;Min:0.00~5.00mA |
Test time range/ resolution | 1~300s 1s/step |
DC Hipot | |
Output voltage setting range/ precision | DC 200~5000V ±(3%×setting value+5 words) |
Breakdown current test rang | 0.10~10.00mA ±(3%×display value+5 words) |
Breakdown current presetting alarm range | Max:0.10~10.00mA;Min:0.00~5.00mA |
Test time range/ resolution | 1~300s 1s/step |
Insulation resistance | |
Output voltage setting range/ precision | DC 500/1000V ±(3%×reading +5 words) |
Insulation resistance testing range / precision | 1~2000MΩ ≤100MΩ:±(5%×display value +3 words) >100 MΩ:±(8%×display value +8words) |
Insulation resistance alarm setting range | Max:0~2000MΩ;Min:1~2000MΩ |
Test time range/ resolution | 1~300s 1s/step |
Grounding resistance | |
Grounding current output range/ precision | AC 5.0~30.0A ±(3%×setting value +5 words) |
Grounding resistance testing range/ precision | 10.0~600mΩ ±(3%×display value+5 words) |
Grounding resistance alarm setting range | Max:5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ; |
Test time range/ resolution | 1~60s 1s/step |
Leakage | |
Output voltage | 1.06 times rated voltage |
Leakage type setting | Dynamic leakage, static leakage ,optional equipped with 3 types of body network ,,which can be customized and switched freely. |
Output voltage testing range / precision | AC 50~280V ±(0.5%×display value+2words) |
Leakage current test range/ precision | 0.05~20.00mA ±(1.5%×display value +0.02mA) |
Leakage current setting alarm range | Max:0.05~20.00mA;Min:0.01~5.00mA |
Test time range | 1~300s 1s/step |
Power | |
Output voltage | 1.0 times rated voltage |
Output voltage testing range / precision | AC 50~280V ±(0.5%×display value+2words) |
Output current testing range / precision | AC 0.20~30.00A ±(0.5%×display value+2words) |
Active power testing range / precision | 30~6000W ±(0.5%×display value+5words) |
Multi-position setting | 4 positions can be set, identify position switch automatically, each position can display corresponding test data after complete the test. |
Power setting alarm range | Max:3~6000W Min:0~6000W |
Test time range / resolution | 1~300s 1s/step |
4. Feature
5. Usage
The safety testing system is used for testing the Hipot of high
voltage elements, it is mainly used to detect whether the product
has leakage current, grounding reliable and harmless to the human
body. The main test items include voltage, leakage current,
insulation resistance and grounding resistance.
6. Production on site