Home Companies Pego Electronics (Yi Chun) Company Limited

PLC Control Environment Test Equipment High - Low Temp Shock Test Chamber AC380V 50HZ

Pego Electronics (Yi Chun) Company Limited

Contact Us

[China] country

Trade Verify

Address: No. 317, Yichun South Road ( Happiness Park), Yuanzhou District, Yichun, Jiangxi, 336000, China

Contact name:Penny Peng

Inquir Now

Pego Electronics (Yi Chun) Company Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

PLC Control Environment Test Equipment High - Low Temp Shock Test Chamber AC380V 50HZ

Country/Region china
City & Province yichun jiangxi
Categories Solar Chargers
InquireNow

Product Details

Precision High - Low Temperature Shock Test Chamber from -40℃ to +150℃

 

1. Introduction

The thermal shock test, also known as the temperature shock test or the high and low temperature impact test, is used to assess the adaptability of the product to the rapid changes in the ambient temperature. It is an indispensable test in the identification test of the equipment design and the routine test in the batch production phase. In some cases, it can also be used for environmental stress screening tests.

The thermal shock test chamber is divided into two-box type and three-box type. The difference is that the test method and internal structure are different. The product conforms to the standard: GB/T2423.1-2008 test A, GB/T2423.2-2008 test B, GB- T10592-2008, GJB150.3-198, GJB360A-96 Method 107 Requirements for temperature impact test. The thermal shock test chamber is an indispensable test equipment for the metal, plastic, rubber, electronics and other materials industries. It is used to test the degree to which a material structure or composite material can withstand in a transient environment of extremely high temperature and extremely low temperature. It is possible to detect chemical changes or physical damage caused by thermal expansion and contraction in the shortest time.

 

Standard:MIL STD,GB,JIS,JEDEC,IEC60068-2-3

 

2. Parameters:

High temperature range+80℃~ +200℃
Low temperature range-10℃~ -60℃
Temperature cyclic range-40℃~ +150℃

Temperature fluctuation

±1.0℃

Temperature uniformity

±1.0℃

Accuracy±2℃
Resolution0.01℃
Rising time at hot spaceRT~150℃ <40mins
Rising time at cold spaceRT~-40℃ < 50mins
Recover time at test space(-40℃~+150℃): 3~5 mins
Weight of EUT5kg above
Constructionhigh temperature chamber, low temperature chamber, test chamber
Interior Size (W*D*H)

60L (500mm*300mm*400mm)

80L (400mm*400mm*500mm)

100L (500mm*400mm*500mm)

150L (500mm*500mm*600mm)

 

3. Features

●Thermal insulation material:High-density glass wool and high strength PU foamed insulation

● High-low temperature automatic switching equipment

● Power supply: 3 phase 5 wires (AC380V, 50HZ)

● Working conditions requred: 0℃~35℃, ≤85%R.H

● Equipment consists by: high temperature chamber, low temperature chamber, test chamber, control system, cooling system, heating system, air duct system, drainage system

● Control system: TEMI880N+LCD touch screen

 

4. Working Pricinple:

A. Low temperature storage room: The temperature state inside the tank is determined by the working state of the heater, evaporator and fan in the air duct. After the refrigerant flowing out through the expansion valve enters the evaporator in the working chamber, the heat in the working chamber is absorbed and vaporized, so that the temperature of the working chamber is lowered; the working fluid after gasification is sucked by the compressor and compressed into high temperature and high pressure gas into the condenser. The medium is condensed into a liquid, and after being screened, finally throttled by the expansion valve, and then re-entered into the evaporator of the working chamber to absorb heat and vaporize and then be sucked and compressed by the compressor. So reciprocating loop work, the studio temperature is lowered to the set temperature requirements.

 

B. High-temperature storage room: The central controller detects the instantaneous signal from the temperature-sensing component, compares it with the set temperature signal, and obtains the comparison signal. The output of the instrument PID logic circuit controls the turn-on or turn-off time of the solid-state relay to adjust the heater output power. In order to achieve the purpose of automatic temperature control.

 

C. Impact temperature test chamber: The high and low temperature air valve is automatically controlled by the meter, and is switched between the low temperature or high temperature storage chamber, and a closed circuit air circulation system is formed respectively with the high temperature box or the low temperature box to quickly reach the target temperature of the test.

 

The temperature state in the test chamber is determined by the operating conditions of the heater, evaporator, and fan in the duct. The working chamber of the test box adopts the forced axial flow “scattering” type loop wind operation, which can greatly improve the parameters such as fluctuation and uniformity of equipment operation.

 

5. FAQ

1. What is the warranty period of the equipment?
Answer: the equipment warranty is 12 months upon you receipt of the equipment

 

2. Can you provide third-lab calibration certificate?
Answer: Yes, the equipment can send to the third-labs authorized by ISO17025 and get the calibration certificate, but the buyer should undertake the charges.

 

3. Does this equipment has English operation interface?
Answer: of course, yes, the operation interface has English instruction.

 

4. Your power plug can not be used in our country, can you change it for us?
Answer: yes, we will change the power plug to fit your demands, please subbmit this issue when you make order.

 

Hot Products

Luminaire Short Circuit Protection Test Chain with Resistance Value of 2.5Ω/m±20% 1. Usage 1). The ...
200MHz 7 inch TFT - LCD Digital Oscilloscope with 2 Channel and Screen Protect Function 1. ...
Auto Testing Machine Flame Resistance Test Glow Wire Testing Equipment with 999s Burning Time ...
IEC60695-2-10 Fire Testing Equipment Glow Wire Tester with Observation Window 1. Standard of Glow ...
Needle Flame Tester Electrical Instrument Test Equipment with 35mm length Burner and Black ...
IEC60112 Industrial electrical Test Equipment Tracking Tester with Platinum Electrode 1. Standard of ...