Home Companies Qingdao Hengfengyou Electrical Engineering Co., Ltd.

Insulation Electrical Switchgear For UZ UK RU Market Rated Frequency(Hz)50 Low Voltage Cabinet Low Voltage Switchgear

Qingdao Hengfengyou Electrical Engineering Co., Ltd.
Active Member

Contact Us

[China] country

Address: N0.506 Huicheng Road, Chengyang District, Qingdao City,China

Contact name:Jack

Inquir Now

Qingdao Hengfengyou Electrical Engineering Co., Ltd.

Insulation Electrical Switchgear For UZ UK RU Market Rated Frequency(Hz)50 Low Voltage Cabinet Low Voltage Switchgear

Country/Region china
City & Province qingdao shandong
Categories Other Chargers
InquireNow

Product Details

Insulation Electrical Switchgear For UZ UK RU Market Rated Frequency(Hz)50 Low Voltage Cabinet Low Voltage Switchgear

Product description

MNS Drawout Low-Voltage Switchgear is assembled with modularized components as combination unit (hereinafter called the device). It is applied to AC 50-60Hz @ rated operating voltage of 660V or below for power receiving and distribution of low voltage distribution system and for power switching, distribution and control of power distribution and motor control center as well as capacitance compensation. The switchgear cabinet complies with GB7251.12-2013.

 

Structural features:

The frame is adopted with C profiles. The mounting holes in ∅5.3mm with module E=25mm on the main framework enables its assembly flexible and convenient.Framework, component door and electrical appliance are made of cold rolled steel plate 2 thickness, and other parts are made of cold rolled steel plate with 1.5 thickness. The panel is cleaned by pickling and phosphating and then electrostatic spraying. Framework, internal partition plate and drawer parts are made of cold-rolled white galvanized sheet or aluminum-zinc sheet, all of which are assembled by self tapping, and the accuracy and firmness of the parts are improved after assembly. There are separate function units, bus room and cable outlet room. Unit isolation room with plastic plate, equipped with L type a copper line. The arrangement of the horizontal bus adopts the flat type after the cabinet or the sitting way of the top of the cabinet. The ability to resist electric power is strong. The connection between the power distribution unit and the external cable is completed in the cable room or in the post outlet room. The cable can go up and down, and the installation and maintenance are convenient. The degree of protection is IP3X-4X.Glass door cabinet at least 650mm, cabinet depth of at least 700mm.

 

Conditions of use

1. For indoor use, the elevation of the service point shall not exceed 2000m.

2, the ambient air temperature is not higher than +40 degrees, not lower than negative 5 degrees.The average temperature should not be higher than +35 degrees within 24 hours.When exceeding, the capacity should be reduced according to the actual situation.

3. The relative high temperature of the surrounding air is +40 ° c and does not exceed 50%, and a large relative temperature is allowed at a lower temperature;If +20 degrees is 90%, consideration should be given to the effect of occasional condensation caused by temperature changes.

4. When the device is installed, the tilt with the vertical plane shall not exceed 5°, and the whole set of cabinets shall be relatively flat in line with the standard of gbj232-2.

5. The device shall be installed in a place where there is no severe vibration and impact and no corrosion of electrical components is sufficient to use

 
4. Electrical panels Basic Parameters
 
ItemUnitParameter
Rated operating voltageVAC380,660
Rated insulation volatgeVAC660,1000
Horizontal busbar current ratingA1250 2000 2500 3200
Vertical busbar current ratingA1000
Max. feeder circuit currentA2500
Max. drawer circuit currentA630
Max. control motor capacitykW320
Rated frequencyHz50/60
Horizontal busbar peak withsatnd currentkA/0.1s105,176
Horizontal busbar short-time withstand currentkA/1s50,80
Vertical busbar peak withstand currentkA/0.1s105
Vertical busbar short-time withstand currentkA/1S50
Rated power freq. withstand voltageV/1min.2500
Secondary power freq. withstand voltageV/1min.2500
Enclosure protection degree IP30,IP40
 

 

5.  Order information

Schematic diagram of main circuit or electrical schematic diagram
Arrangement and layout
Model, specification and quantity of main components.
Incoming and outgoing wire method and cable specification, etc
If bus connection is required between the devices, bus connection and height from the ground shall be provided.

 

Working Environment

1. Indoor altitude above sea level: Maximum installation altitude: 2000m

2. Ambient air temperature: -5℃~+40℃ and the average temperature should not

exceed +35℃ in 24h

3. Relative humidity should not exceed 50% at max temperature +40℃. Higher

relative humidity is allowed at lower temperature. Ex. 90% at +20℃. But in view of

the temperature change, it is possible that moderate dews will produce casually.

4. No fire, explosion danger, serious pollution, chemical corrosion and severe vibration

5. Installation gradient not exceed 5°

6. This product is suitable for the following temperature transportation storage: -25 ~+55 24h, in a short period of time (no more than 24hours) not more than+70℃.

Characteristics

This series of products with high breaking capacity, good dynamic stability, advanced and reasonable structure, electrical program of practical, series, strong versatility, various schemes of unit combination, a cabinet contained many circuits, save the area , beautiful appearance, high level protection, safe and reliable, convenient maintenance etc.

It accords with the standards IEC439 NEMA ICS2-322 as well as the GB7251-87 “Low voltage complete switch device ” national standards and ZBK36001-89 "low voltage withdraw type complete switch device” professional standards"

 

 

 

Hot Products

Electrical Cast Resin Dry Type Transformer 11~35kv Intdoor Dry Type Transformer SC(B)10, SC(B)11, SC...
SC(B)10 Series Resin-insulated Dry Type Transformer,cast resin transformer,dry-type transformer,cast ...
11KV 500KVA Three Phase Toroidal Dry Type Electrical Transformer With Price A. the material of iron ...
SCB10 3 Phase 415v to 220v Dry Type Step Down Distribution We can make Cast Dry-Type Transformer , ...
11kV VPI Open Ventilated Dry Type Transformer The three-phase dry-type phase-shifting frequency ...
(SC(B)-35) 35kv Dry-Type Transformer 1.Product Description Our SC(B) series epoxy resin cast dry ...