Home Companies Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

380V R134A Refrigerant Flooded Water Cooled Screw Chiller

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Active Member

Contact Us

[China] country

Address: Euroklimat Industrial Park, Huangjiang Dongguan Guangdong China 523766

Contact name:LENG Zhengliang

Inquir Now

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

380V R134A Refrigerant Flooded Water Cooled Screw Chiller

Country/Region china
City & Province dongguan guangdong
InquireNow

Product Details

 
Flooded water cooled screw chiller R134a
 
 
Overview
 
Water (ground) heat pump system is an efficient and energy-saving air-conditioning system that uses the shallow geothermal resources (also known as ground source energy, including underground water, soil, orground surface water) to provide heating and cooling. The system realizes shift of low temperature thermal energy to high temperature thermal energy by introducing few electricity energy. The ground source energy is used as the heat source for heat pump in winter and the cooling source for air-conditioner in summer. The unit consumes energy of 1 kW to obtain more than 4 to 5 kW cooling/ heating capacity. The energy sources from underground. The system does not discharge any waste gas, water, or residue, making it an ideal green air-conditioner that can be widely used in office buildings, hotels, schools, dormitories, hospitals, guesthouses, malls, villas, and residential areas.
 

 
Unit Features
 
1. Single system flooded evaporator Multi-compressor single-system design.


The industry-leading single-system flooded evaporator design and multicompressor single-system design enable the single compressor system to provide cooling capacity of up to 500 RT. The compressors start one by one, greatly reducing shock of the startup current on the grid. In partial load, the dual compressors run by turns, providing a long life cycle.
 
2. Oil separation efficiency as high as 99.95% 


The air return outlet of the flooded evaporator is directly connected to the air suction inlet of the compressor. The optimal built-in oil route lubricating system is equipped with an innovative external efficient oil separator, which has a unique structure to change the flow direction and works with a multi-layer high-density oil filter to deliver the optimal oil separation effect with efficiency of more than 99.95%. The air return outlet of the flooded evaporator is directly connected to the air suction inlet of the compressor. This effectively reduces pressure loss and ineffective overheat of the air suction pipeline. Such design is compact, efficient and energy-saving.
 
3. Environment-friendly R134a refrigerant


The refrigerant injection amount is reduced by 50% or more compared with a traditional flooded unit. The lubricant injection amount is reduced by 50% or more compared with a traditional flooded unit. Applicable to heat pump, full heat recovery, and cooling accumulation conditions.
.
4. Efficient and stable R134a flooded screw compressor
 
■ EK’s latest leading R134a efficient dual-screw compressor technology specifically designed for flooded unit is used. The maximum cooling capacity of a single-compressor system can reach 450 RT, efficiently reducing the number of compressors while obtaining high full-load COP. The full series unit meets
national requirements for energy efficiency of energy-saving air-conditioning products.
■ Direct connection design
The air return outlet of the flooded evaporator is directly connected to the air suction inlet of the compressor. This effectively reduces pressure loss and ineffective overheat of the air suction pipeline. Such a design is compact, efficient and energy-saving.
■ Oil supply upon pressure difference
The optimal built-in oil route lubricating system is equipped with an innovative external efficient oil separator. The oil is supplied through pressure difference. The structure is simple, safe and efficient.
■ Oil spray and noise reduction
The unique oil spray and noise reduction function can spray a small amount of lubricant to the air exhaust side, and form an even oil film on the surface of the rotor to absorb sound energy and reduce the overall noise of the compressors. In addition, the even oil film can efficiently lubricate and seal, reducing the leakage amount and improving compressor efficiency.
■ Motor cooling
International famous efficient dual-pole three-phase F-level insulation induction motor is used. The independent motor cooling and heat dissipation design efficiently reduces the air suction pressure loss and invalid overheat of air suction. A PT100 temperature sensor is built in, and an INT69 module array is configured to protect the motor, providing active control on motor temperature rise. The coil temperature of the compressor motor can be accurately monitored and regulated to ensure long-term and wide-range running of the motor in the running range of the compressors
■ The design of smart control on even spray for liquid refrigerant is adopted, improving the compressor efficiency while fully reducing the risks of large-amount leakage of refrigerant and lubricant. In addition, no heat is discharged to the equipment room, saving the initial investment and running expenses for cooling equipment in the equipment room.
■ Capacity spool
The spool-type load adder/reducer device is used as the compressor regulation mode. The capacity spool structure configures a highly reliable international brand electromagnet for precise control and perfect match with actual load to ensure efficient running of the unit, provide comfort and save the energy.
■ Dual-layer shell
A fine dual-layer shell f o r g e d b y g r a y c a s t iron and processed by precision M/C machine tools is used. A threedimensional precision tester is used to test the processing precision, ensuring that the gap of the compressor meets the requirements of highefficiency calculation.
The dual-layer design complies with pressure-bearing requirements, and reduces the noise. Such a high-strength and high-rigidity design ensures long-term running of the compressor.
 
5. Efficient heat exchanger
 
■ All internal heat exchange pipes use efficient heat exchange copper pipes with inner and outer
threads to ensure optimal heat exchange flow rate of the refrigerant and chilling medium, enhance the
heat transfer at the water side and refrigerant side, optimize the heat transfer efficiency, reduce energy
consumption of the unit, and lower the running expenses.


■ The evaporator adopts the latest efficient flooded design to efficiently reduce the filling amount of
the refrigerant by 50% or more compared with a traditional flooded heat exchanger.


■ The unique built-in over-cooling design of the system can fully avoid hydraulic shock of compressors and improve the cooling capacity and efficiency of the unit.


■ The multi-level automatic oil return system accurately returns oil regardless of theliquid level, eliminating impact on heat exchange efficiency.


■ The standard piping mode provided by the heat exchanger is trough coupling connection (with short tube), facilitating field installation. Each evaporator and condenser is equipped with independent air exhaust and water drainage devices.
 
6. Precise and efficient liquid level control
 
■ The full series adopts liquid level controller with high-resolution digital display and international famous brand electronic expansion valve to steadily control the liquid level of the evaporator at the optimal position so that the unit achieves the optimal heat exchange effect at any load. This ensures high performance running of the unit and apparently improves the efficiency under partial load.
 
7. Smart Control
 
■ The large-screen LCD developed by EK is directly connected to the digital control center, greatly improving efficiency and providing monitoring, data recording, security protection, and easy operations.
■ The chilled water outlet temperature is controlled to a precision of ±0.2oC. Various sensors in the system can accurately transfer signals and data to the controller so that the controller can protect unit parts in a timely manner, ensuring reliable running of the unit.
■ Three-level password protection prevents mis-operation by non-professional personnel and ensures safe running of the unit. In addition, multiple protection functions are provided.
■ All running parameters and alerts of the unit can be recorded and saved.
■ The start/stop of the unit can be remotely controlled and data can be transmitted over Internet.
 
8. Centralized control
 
EK centralized control system adopts the industryleading control solution. The product configuration
is applicable to the control system solution for the chilled pump, cooling pump and cooling tower.
Multiple persons are allowed to control and monitor the unit on the homepage of a Microsoft-based web
browser.
 

 

 

ModelEKSC062EKSC072EKSC084EKSC095EKSC116EKSC133EKSC152EKSC173EKSC187EKSC196
Cooling capacityU.S.RT62728495116133152173187196
kW216.8253.0294.8334.7408.0466.0536.3609.7658.1691.0
×104 kcal/h18.621.825.428.835.140.146.152.456.659.4
Cooling power inputkW42.850.056.964.878.989.3102.4115.6128.0133.1
COP5.075.065.185.175.175.225.245.275.145.19
Chilled water flow rate37.343.550.757.670.280.292.2104.9113.2118.9
Chilled water pressure drop43454546495051535454
Water source flow rate46.654.463.472.087.7100.2115.3131.1141.5148.6
Water source pressure drop43454648505152545555
CompressorTypeSemi-hermetic dual-screw compressor
Qty.1111111111
Start up typeY-Δ
Capacity modulation%25%-100% stepless
Power supply380V~415V/3N~/50Hz
CondenserTypeWater-cooled shell-tube type
Qty.1111111111
EvaporatorTypeFalling film
Qty.1111111111
Refrigerant typeR134a
LubricantCodeEK07
FillingL16151823232328284040
Temperature controlChilled water temperature PID control
Outer diameter of chilled
water inlet/outlet pipe
φ(mm)139.7139.7139.7139.7168.3168.3168.3168.3168.3168.3
Outer diameter of cooling
water inlet/outlet pipe
φ(mm)139.7139.7139.7139.7168.3168.3168.3168.3168.3168.3
Heat-insulation materialFlexible elastomeric foam insulation
Net weight 2350272027602890335034403580369039904040
Gross weight 2460285028903020353036303790392042604320
Rated current (cooling)A8396110127147166183214239244
Start up currentA230233270292407447522663753753
Max. startup current
(cooling)
A110130147172192218259294350365
Main power wiring diametermm23x503x503x703x703x953x1203x1503x1853x1853x185

 

 

ModelEKSC207EKSC224EKSC252EKSC265EKSC282EKSC293EKSC232EKSC265EKSC305EKSC347
Cooling capacityU.S.RT207224252265282293232265305347
kW729.4787.8886.7931.1992.01031.7816.1932.01072.81219.3
×104 kcal/h62.767.876.380.185.388.770.280.292.3104.9
Cooling power inputkW141.2149.0169.5174.9188.6193.3157.6178.6204.7231.2
COP5.175.295.235.325.265.345.185.225.245.27
Chilled water flow rate125.5135.5152.5160.1170.6177.5140.4160.3184.5209.7
Chilled water pressure drop54545656565674757678
Water source flow rate156.8169.4190.6200.2213.3221.8175.5200.4230.7262.1
Water source pressure drop57575858585874747677
CompressorTypeSemi-hermetic dual-screw compressor
Qty.1111112222
Start up typeY-Δ
Capacity modulation%25%-100% stepless12.5%-100% stepless
Power supply380V~415V/3N~/50Hz
CondenserTypeWater-cooled shell-tube type
Qty.1111111111
EvaporatorTypeFalling film
Qty.1111111111
Refrigerant typeR134a
LubricantCodeEK07
FillingL40405353535323+2323+2328+2828+28
Temperature controlChilled water temperature PID control
Outer diameter of chilled
water inlet/outlet pipe
φ(mm)168.3168.3219.1219.1219.1219.1219.1219.1219.1219.1
Outer diameter of cooling
water inlet/outlet pipe
φ(mm)168.3168.3219.1219.1219.1219.1219.1219.1219.1219.1
Heat-insulation materialFlexible elastomeric foam insulation
Net weight 4090418048804990520052905860600062606530
Gross weight 4370449052505380569058006190636066707000
Rated current (cooling)A265278310320337350294332366428
Start up currentA75375388888888888881389310431327
Max. startup current
(cooling)
A380402432445458474385436518588
Main power wiring diametermm23x2403x2406x1206x1206x1206x1206x956x1206x1856x185

 

 

ModelEKSC374EKSC393EKSC415EKSC448EKSC504EKSC529EKSC564EKSC587
Cooling capacityU.S.RT374393415448504529564587
kW1316.31382.11458.91575.61773.51862.11984.02063.3
×104 kcal/h113.2118.9125.5135.5152.5160.1170.6177.4
Cooling power inputkW255.9266.3282.5298.0339.0349.7377.1386.7
COP5.145.195.165.295.235.325.265.34
Chilled water flow rate226.4237.7250.9271.0305.0320.3341.2354.9
Chilled water pressure drop7979808082828383
Water source flow rate283.0297.2313.7338.8381.3400.4426.6443.6
Water source pressure drop7878808082828383
CompressorTypeSemi-hermetic dual-screw compressor
Qty.22222222
Start up typeY-Δ
Capacity modulation%12.5%-100% stepless
Power supply380V~415V/3N~/50Hz
CondenserTypeWater-cooled shell-tube type
Qty.11111111
EvaporatorTypeFalling film
Qty.11111111
Refrigerant typeR134a
LubricantCodeEK07
FillingL40+4040+4040+4040+4053+5353+5353+5353+53
Temperature controlChilled water temperature PID control
Outer diameter of chilled
water inlet/outlet pipe
φ(mm)219.1219.1219.1219.1273273273273
Outer diameter of cooling
water inlet/outlet pipe
φ(mm)219.1219.1219.1219.1273273273273
Heat-insulation materialFlexible elastomeric foam insulation
Net weight 67706950705072308620883090409260
Gross weight 726074607620782093309600985010540
Rated current (cooling)A478488530556620640674700
Start up currentA15071507150715071777177717771777
Max. startup current
(cooling)
A700720760780880900930950
Main power wiring diametermm29x1509x1859x1859x1859x2409x2409x2409x240

 
 

Hot Products

Features 1. Copeland scroll compressor or Danfoss scroll compressor 2. Plate heat exchanger or shell ...
Totally Heat Recovery Air Cooled Modular Chiller 130KW Features 1. Copeland scroll compressor or ...
Tropical area air cooled scroll chiller max working ambient temperature 56 C Features 1. 4 nos ...
EVI air cooled scroll chiller Features 1. 4 nos Copeland scroll compressors 2. Plate heat exchanger ...
345KW air cooled scroll chiller Features 1. 3 nos Copeland/Danfos/ scroll compressors 2. Shell tube ...
50KW Air Source Heat Pump Water Heater Features 1. EVI famous brand scroll compressor 2. Plate heat ...