Horizontal type Compact return 30mm PU insulation Air Handling Units with jet

 

Specifications

 

ModelEKDW
020S
EKDW
030S
EKDW
040S
EKDW
050S
EKDW
060S
EKDW
070S
EKDW
080H
EKDW
090S
EKDW
100S
EKDW
120S
Nominal air flow (m3/h)200030004000500060007000800090001000012000
Nominal cooling capacity (kW)4 rows of coils (return air)12172431384451566374
4 rows of coils (fresh air)294257698394113127142169
6 rows of coils (return air)15233339485563727894
6 rows of coils (fresh air)35536988105122137155173208
Nominal heating capacity (kW)4 rows of coils (return air)1930415061718393103122
4 rows of coils (fresh air)3349668299115133148161197
6 rows of coils (return air)23364860728496108120144
6 rows of coils (fresh air)38577795114132150169188224
Nominal cooling water flow (L/S)4 rows of coils (return air)0.570.811.141.481.812.102.432.673.003.52
4 rows of coils (fresh air)1.382.002.713.293.954.485.386.056.768.05
6 rows of coils (return air)0.711.101.571.862.292.623.003.433.714.48
6 rows of coils (fresh air)1.672.523.294.195.005.816.527.388.249.90
Nominal heating water flow (L/S)4 rows of coils (return air)0.430.680.921.131.371.711.872.242.322.75
4 rows of coils (fresh air)0.741.101.491.852.232.772.993.563.624.44
6 rows of coils (return air)0.520.811.081.351.622.022.162.602.703.24
6 rows of coils (fresh air)0.861.281.732.142.573.173.384.064.235.04
CoilTypeCopper tube with a new type of wavy aluminum fins
Piece/inch13
Working pressure (MPa)1.6
Size of inlet/outlet water
pipe connector
R 1-1/2R 1-1/2R 1-1/2R 1-1/2R 1-1/2R 2R 2R 2R 2R 2
Size of condensate water
pipe connector
R1-1/4
FanType/materialHigh-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates
TransmissionV-belt transmission
Fanning directionDownward horizontal/top
Rang (number of nozzles)4 rows of heat exchangersI

10~20

m(1)

10~20

m(2)

10~20

m(2)

10~20

m(2)

10~20

m(2)

10~20

m(2)

10~20

m(2)

10~20

m(2)

~~
II

20~30

m(1)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

III~~~

30~40

m(1)

30~40

m(2)

30~40

m(1)

30~40

m(1)

30~40

m(1)

30~40

m(2)

30~40

m(2)

6 rows of heat exchangersI

10~20

m(1)

10~20

m(2)

10~20

m(2)

10~20

m(2)

10~20

m(2)

10~20

m(2)

10~20

m(2)

10~20

m(2)

~~
II

20~30

m(1)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

20~30

m(2)

III~~~

30~40

m(1)

30~40

m(2)

30~40

m(1)

30~40

m(1)

30~40

m(1)

30~40

m(2)

30~40

m(2)

Motor power (kW)4 rows of heat exchangersI0.550.750.751.11.51.51.52.2~~
II0.751.11.11.52.22.22.23.03.04.0
III~~~2.23.03.03.04.05.55.5
6 rows of heat exchangersI0.751.11.11.11.51.51.53.0~~
II1.11.51.51.52.22.22.233.04.0
III~~~2.23.03.03.04.05.55.5
FilterTypeThickness (mm)
Thickness (mm)8/21
CabinetType30mm-thick double-layer plates filled with polyurethane material foamed under
high pressure for heat preservation
Unit
Dimensions
Length (mm)82095010101130126013001500162016501750
Width (mm)1450145015501550155016001600160015501550
Height (mm)630650755755805830830830890950
Unit weight
(kg)
4 rows of heat exchangers135149179195222247282300369389
6 rows of heat exchangers139156187204232260297316388411

 

EKDW features a professional air jet solution that is suitable for areas that is super large or high, areas where no air duct is installed, areas where air ducts cannot be installed and areas where conditioned air cannot be supplied to the bottom of a building from the rooftop. Such areas include air ports, bus stations, exhibition centers, factory plants, supermarkets, and lobbies, front doors and shafts of hotels.

 

EKDW air jet units use high-performance ball-shaped sprayer as the air outlet, and can supply air over a maximum distance of 40 meters. The units can supply conditioned air over a long distance without air duct, thus saving space and operation cost and lowering the requirement on floor distance.

 

EKDW air jet units can supply air 360° and the air supply direction can be manually adjusted. The air is similar to natural air and does not directly blow on people.Conditioned air is supplied to specified locations in the most comfortable way. Wide access door makes maintenance work very convenient.

 

Optional accessories such as temperature/pressure drop alarms are available.Both air inlet and outlet are equipped with a flange to facilitate air coil connection.The unit can be mounted on the floor or hung from the ceiling.

 

Functional section

 

Mixing
Primary efficiency filter : Nylon filter , Aluminum Filter, G3,G4 filter
Bag  filter :F5,F6,F7,F8
Cooled coil 
Heating coil 
Electric heater
Wet film humidifier
UVC
Fan 

Hot Products

68kW R410A Refrigerant Air Cooled Modular Chiller with DANFOSS Compressor Specifications: EKAC ...
R410a air cooled modular chiller 68KW/90KW/95KW/100KW/134KW/150KW Specifications: Basic Model ...
Features 1. Copeland scroll compressor or Danfoss scroll compressor 2. Plate heat exchanger or shell ...
Totally Heat Recovery Air Cooled Modular Chiller 130KW Features 1. Copeland scroll compressor or ...
Tropical area air cooled scroll chiller max working ambient temperature 56 C Features 1. 4 nos ...
EVI air cooled scroll chiller Features 1. 4 nos Copeland scroll compressors 2. Plate heat exchanger ...