Home Companies Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

Airport installation modular AHUs with KRUGER fan VFD max 800 tons

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Active Member

Contact Us

[China] country

Address: Euroklimat Industrial Park, Huangjiang Dongguan Guangdong China 523766

Contact name:LENG Zhengliang

Inquir Now

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd

Airport installation modular AHUs with KRUGER fan VFD max 800 tons

Country/Region china
City & Province dongguan guangdong
Categories Toilet Tissue
InquireNow

Product Details

EK keeps looking for valuable distributors and partners around international markets…

 

Airport installation modular AHUs with KRUGER fan VFD max 800 tons

 

 


PUFOAM insulation thickness :30/50mm

 

External sheet  : 0.5 mm preplasticized steel standard , 1 mm is optional
Internal sheet  : 0.5 mm Galvanised steel standard , 1 mm is optional

 

Aluminum frame
Base height : 50 mm /80 mm

 

Sections : Mixing section,Prefilter section,Medium filter section ,HEPA Filter section ,Cooling coil section,Heating coil section , Wet film humidifier / Elec trode humidifier / steam humidifier / HP Atomizing humidifier /Electric heater humidifier section ,Electric heater section , Fan section ,Diffusion section ,muffler section 

 

Heat recovery wheel section , Plate heat recovery section ,Access door section 


Mixing section: Return air damper ,Fresh air damper 

 

Prefilter : Nylon ,panel G3/G4 ,Bag G3/G4
Medium filter : F5,F6,F7,F8
HEPA Filter :H10,H11,H13
Pressure swich & gauge are optional

Access door section :  light & window are optinal


Cooling coil : Row 2 3 4 5 6 8 10 12; Aluminum fins : 11 12 13 14 15 16 FPI
Heating coil : Row 1 2 3 4  ; Aluminum fins : 11 12 13 14 15 16 FPI
Drain Pan :Zinc Painting Steel;SS304 is optional
Hydrophilic Aluminum fins is optional

 

Supply fan :Yilida/Kruger , backward/forward centrifugal type standard , plug fan is optional

 

Motor : ABB,SIEMENS,Chinese Brand, variable frequency motor is optional 

 

TEFC/IP55/F  TEFC/IP54/F

 

VFD & start cabinet are optional

 

Controller : Optional

 

Mixing Box 

 

 

Model
EKDM
Rated air flow m3/hDimensions (mm)
WHLA1A2B1B2CDEF
306200010105303M350350300300330115330115
406300010106903M500500300300255195255115
407400011706903M600600300300285195285115
408500013306903M700700300300315195315115
508600013308503M7007004304303155031550
6077000117010103M6006004304302855028550
6088000133010103M8008004304302655026550
511900018108503M100010004304304055040550
61010000165010103M100010004304303255032550
61112000181010103M110011004304303555035550
71215000197011704M110011005905904355043550
81218000197013304M130013005905903355033550
81320000213013304M140014005905903655036550
91525000245014904M150015007505904755047550
101530000245016504M160016007505904255042550
131335000213021305M1300130010707504155041550
131540000245021305M1500150010707504755047550
151545000245024506M1500150012309104755047550
141750000277022906M1700170012309105355053550
152060000325024506M2000200012309106255062550
172070000325027707M20002000155010706255062550
172280000357027707M22002200155010706855068550
162690000421026107M26002600139010708055080550
1826100000421029307M26002600171010708055080550
1852200000837026107M52005200171010708055080550
3652400000837059107M52005200342021408055080550

 

 

Note:
■ The width and height for mixing boxes listed above are for units with a 30mm-thick panel. For units with a 50mm-thick panel, the
parameters need a 40mm increase.
■ Standard mixing boxes are equipped with manually-divided multi-leaf hermetic air valves. Electric air valves are also available for auto
control. Air valves are made from zinc-galvanized plates or aluminum alloy with an optional flange.
■ A1 x B1 represents the windward area of return air valve; A2 x B2 represents the windward area of fresh air valve.
■ For total return air, the wind speed at the return air valve is 5~6 m/s; for total fresh air, the wind speed at the fresh air valve is no
larger than 9m/s.
■ The unit height (H) does not include the height of its base.

 

 

Specifciations 

 

Model
EKDM
Rated air flow m3/hWindward area of coil (m2)Air flow (m3/h)Diameter  of fan impeller mmFan performance
2.252.502.753.00Max. total pressure of fan PaMax. motor power kW
m/sm/sm/sm/s
30620000.23186320702277248416013002.2
40630000.34275430603366367220013003
40740000.41332136904059442822515003
40850000.48388843204752518425018005.5
50860000.65526558506435702028018007.5
60770000.69558962106831745228018007.5
60880000.81656172908019874831518007.5
51190000.9476148460930610152315180011
610100001.05850594501039511340355200011
611120001.179477105301158312636400200015
712150001.5512555139501534516740450200015
812180001.8114661162901791919548500200018.5
813200001.9816038178201960221384500200018.5
915250002.6621546239402633428728560200022
1015300002.9924219269102960132292630200030
1313350003.4027540306003366036720630200030
1315400003.9932319359103950143092710200030
1515450004.6537665418504603550220800200037
1417500004.9540095445504900553460800200045
1520600006.3651516572406296468688900200045
1720700007.2758887654307197378516900200055
1722800008.05652057245079695869401000200075
1626900009.01729818109089199973081000200075
182610000010.21827019189010107911026811202000110
1852200000020.421654021837802021582205361120x22000110x2
3652400000040.843308043675604043164410721120x42000110x4

 

Note:
■ This table only lists some typical models among many models for quick model selection.
■ Total fan pressures listed above are tested on standard fans with rated air flow.
■ External residual pressure = Total fan pressure - Internal resistance. For internal resistance of EKDM units.

Hot Products

68kW R410A Refrigerant Air Cooled Modular Chiller with DANFOSS Compressor Specifications: EKAC ...
R410a air cooled modular chiller 68KW/90KW/95KW/100KW/134KW/150KW Specifications: Basic Model ...
Features 1. Copeland scroll compressor or Danfoss scroll compressor 2. Plate heat exchanger or shell ...
Totally Heat Recovery Air Cooled Modular Chiller 130KW Features 1. Copeland scroll compressor or ...
Tropical area air cooled scroll chiller max working ambient temperature 56 C Features 1. 4 nos ...
EVI air cooled scroll chiller Features 1. 4 nos Copeland scroll compressors 2. Plate heat exchanger ...