SPECIFICATIONS

 

MODEL

200

DA

300

DA

400

DA

500

DA

600

DA

800

DA

900

DA

1000

DA

1200

DA

1400

DA

1600

DA

NOMINAL AIR FLOWHcfm205262391489543805920990139714041861
Mcfm179235359467511762891959129914011749
Lcfm11815926237140864176180998111361360
COOLING CAPACITYTOTALW1660230032803750430065707150791099801049012920
SENSIBLEW9801400204025802850449048705480736078809960
HEATING CAPACITYH35644541615873518705127091441315498207362088725529
RATED POWER INPUTHW84101116148165297299309507603665
MW7892108133154273277290475523607
LW586992110133225232250407428529
RATED CURRENT INPUTHA0.400.480.540.670.811.441.531.582.372.783.10
MA0.360.420.490.620.711.251.281.342.172.462.78
LA0.280.320.430.540.611.021.061.141.852.042.42
WATER FLOW RATEm3/h0.160.220.310.360.410.630.680.750.951.001.23
WATER PRESSURE DROPKPa361368101311141620
EXTERNAL STATIC PRESSUREPa7575757575757575757575
SOUND PRESSURE LEVELdDA(A)42.645.645.346.749.248.748.250.350.950.952.9
CONDENSATE DRAIN PIPERc3/4
UNIT DIMENSIONLENGTHmm6778279279971097142715371727142715271827
WIDTHmm530530530530530530530530600600600
HEIGHTmm243243243243243243243243297297297
PACKING DIMENSIONLENGTHmm68983993910091109143915491739143915391839
WIDTHmm542542542542542542542542612612612
HEIGHTmm255255255255255255255255309309309
NET WEIGHTkg1621222428394448515262
GROSS WEIGHTkg1924252831434853555868
OPERATING WEIGHTkg1722242630414750545466

 

NOTES:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) THE PERFORMANCE DATA ARE BASED ON THE FOLLOWING CONDITIONS:
A) COOLING: 24°C DB/18°C WB INDOOR AND WATER INLET 5.5°C OUTLET 14.5°C.
DA) MEDIUM SPEED,75PA ESP.
C) 220V/1PH/50HZ.
3) ALL THE DIMENSIONS ARE FOR THE UNITS WITH STANDARD DRAIN PAN. TO GET DIMENSIONS FOR UNITS WITH EXTENDED DRAIN PAN,
PLEASE INCREASE THE ABOVE LENGTH VALUES ACCORDINGLY.
4) WHEN THE WATER CONNECT DIRECTION IS CHANGED IN FIELD, THE CAPACITY SHOULD BE REDUCED BY 6%.

 

Main Features

 

General

 

The new EKCW-DA FCUs are specifically designed to satisfy high cooling capacity application requirement. They represent one of the most cost effective solutions to provide a comfortable environment for both commercial and residential applications. Their quiet operation, compact dimensions and particularly low height, make units ideal for ceiling concealed installation even in buildings with narrow ceiling spaces. Units are standard supplied with soundproofed suction plenum and air filter. Centrifugal fans, with forward-curved blades, are statically and dynamically balanced and driven by single-phase motors with three speeds.They feature elegant design, advanced structure, high efficiency, low noise, convenient installation and low maintenance. They are widely used in houses, shopping malls, hospitals and office etc.

 

Higher Cooling Capacity in High Delta T Application

 

These units are particularly suitable for high External Static Pressure and high Delta T(chilled water temperature difference) applications. They can delivery more cooling capacity in high Delta T conditions with the specially designed fans & motors, coils and excellent combination of them.

 

Low Chilled Water Pressure Drop

 

In order to meet even the most demanding customer requirements, the new FCUs adopt the most reasonable and optimized water circuit design and utilize the National accredited thermal test room to guarantee both the perfect performance and a low chilled water pressure drop.

 

Extra High Air Flow Volume at High ESP

 

These units can supply more air flow at high ESP. 11 models of EKCW-DA cover an air flow range from 200 to 1600 CFM at medium speed with ESP of 75Pa.

 

High Efficiency and Energy Saving

 

A boundary layer film of air adhering to the fin surface will insulate the fin surface and severely reduces the heat exchange efficiency. McQuay slit designed and HYDROPHILIC DALUE FIN eliminates this boundary layer of air and creates continuous turbulence for best heat exchange efficiency.

Flexibility

 

Units are available with left or right hand water connections, which can be easily switched in the field by changing the positions of the fan-motor assembly and the supply air flange assembly if required.

Compact Design

 

The low height design makes this fan coil unit series ideally suited for the tight ceiling concealed installation.

 

Low Noise Design

 

Enlarged fan wheels design allows lower fan speed selection for the same external static pressure and airflow requirement. Thereby noise level is significantly reduced.

 

Powerful Selection Software

 

Powerful select software makes various conditions selection precise and cost saving.

The EKCW-DA series terminals are air-conditioning units for systems that use water as cooling and/or heating fluid. These are units for false-ceiling installation designed for the air-conditioning of places such as: banks, shops, offices,homes, hotels, hospitals, etc. Featuring silent centrifugal fans with low/medium static pressure and internal soundproofing, they are suitable for applications with air outlet ducts in the room. The range of versions and accessories available make these units easily adaptable to various types of systems.

Hot Products

68kW R410A Refrigerant Air Cooled Modular Chiller with DANFOSS Compressor Specifications: EKAC ...
R410a air cooled modular chiller 68KW/90KW/95KW/100KW/134KW/150KW Specifications: Basic Model ...
Features 1. Copeland scroll compressor or Danfoss scroll compressor 2. Plate heat exchanger or shell ...
Totally Heat Recovery Air Cooled Modular Chiller 130KW Features 1. Copeland scroll compressor or ...
Tropical area air cooled scroll chiller max working ambient temperature 56 C Features 1. 4 nos ...
EVI air cooled scroll chiller Features 1. 4 nos Copeland scroll compressors 2. Plate heat exchanger ...