High Efficiency Water-cooled Falling Film Centrifugal Chiller

 

Specification

 

Model EKDC500EKDC550EKDC600EKDC650EKDC700EKDC750
Nominal CoolingCooling CapacityU.S.RT510561612663714765
kW179319722152233125102690
x104kCal/h154170185200216231
Input PowerkW293321351381409437
COPkW / kW6.126.146.136.126.146.16
Chilled Water Flowm3/h308339370401432463
Chilled Water Pressure DropkPa626174737384
Cooling Water Flowm3/h359394431466502538
Cooling Water Pressure DropkPa686677767788
Cooling*Cooling CapacityU.S.RT498547597647697746
kW175019252100227524502625
x104kCal/h151166181196211226
Input PowerkW303332363394423451
COPkW / kW5.785.805.795.775.795.82
Chilled Water Flowm3/h301331361391421452
Chilled Water Pressure DropkPa595870696980
Cooling Water Flowm3/h353388424459494529
Cooling Water Pressure DropkPa666475747585
CompressorType Two Stage Semi-hermetic Centrifugal
Start Type Start Delta (Low voltage)
Power Supply 380-415V/3N~/50Hz
CondenserType Shell-Tube
Qty. 111111
EvaporatorType Spray ( Falling Film)
Qty. 111111
Refrigerant R134a
Control Type Water Temp. PID Control
Chilled Water Pipe SizeDN250250250250250250
Cooling Water Pipe SizeDN250250250250250250
Insulation Material Rubber flexible closed foam insulation materials
Unit Net Weightkg9100960010100106001120011200
Operating Weightkg100501055011100117001235012350
Rated Current
(Nominal Cooling)
380VA518570661729802854
6kVA------
10kVA------
Rated Current
(Cooling*)
380VA536590684754829881
6kVA------
10kVA------
Starting Current380VA283528352902311933083308
6kVA------
10kVA------

 

Note:

■ Nominal cooling conditions: Chilled water entering/leaving Temp.:12/7℃,cooling water entering/leaving Temp.:30/35℃;

■ Cooling* conditions :Chilled water entering/leaving Temp.:12/7℃,cooling water entering/leaving Temp.:32/37℃;

■ Water side standard bearing pressure 1.0MPa;

■ Above evaporator and condenser water side pressure drop not including external water pipe and the other parts resistance;

■ Evaporator and condenser water pipe is flange connection;

■ Refer to unit nameplate or manual for job site power supply arrangement.

 

Description

 

EKDC series water-cooled falling film centrifugal chiller adhering to energy saving and environmental protection of the brand concept, can provide chilled water for central air conditioning system in hotel, hospital, pharmaceutical, theater, stadium, recreation center, commercial building, office building, industrial and mining enterprises; also can for textile, chemical, food and electronic research to provide chilled water for process usage.

 

Features

 

Environment Friendly Refrigerant 

 

R134a is environment friendly refrigerant, zero ozone depletion, safety & non-poison, un-burnable, green & environment friendly, comply with current development trend of international environmental protection.

 

High Efficiency two-stage Compression Design

 

Using high efficiency two-stage hermetic impeller compression increases efficiency more than 6%, lower relative speed, lower noise level, small vibration, higher reliability. Adopting three-dimensional flow high efficiency aluminum hermetic impeller design, greatly decrease air leakage;  five-axis machining with higher precision, so can effective reduce impeller axis loss and separate loss, and greatly increase impeller efficiency.  Than unit efficiency is better than national standards for energy conservation.

 

Reliable Oil Recovery Device-Induced Jet Pump

 

Through induced jet pump, on the condition of no energy loss make use of middle pressure steam flashing to achieve low pressure side oil recovery function.

 

Refrigerant Flow Control Kit-Orifice Plate

 

• Use orifice plate to control refrigerant flow. Each set orifice plate is designed and produced according to Centrifugal Chiller performance; so that can get the best match.

• Orifice plate without any moving part, so that it is more reliable than the other throttle valves that need mechanical transmission

 

Spray Type (Falling Film) Evaporator

 

• The refrigerant into the evaporator is a heat exchange tube array on the spray direction. The liquid refrigerant in the tube wall to form a thin film flow down, also known as the falling film evaporator. Because only in the surface of the heat exchanger tube is covered with a layer of liquid refrigerant film, so the heat transfer effect is excellent

• Using refrigerant circulation pump as the refrigerant throttling device from economizer to the evaporator, meanwhile pump out liquid refrigerant in evaporator bottom for recycling; in order to improve the refrigerant supply for evaporator upper copper pipe, so that can make sure that all copper pipes are covered by liquid refrigerant. Unit no need precise water level correction, only for general positioning, evaporator can play high normal performance.

• Only evaporator bottom has a small amount of liquid refrigerant so that refrigerant charge is less, complying with environment protection.

• After a large amount of refrigerant evaporation, lubrication oil concentrate in evaporator bottom; and then oil pump can draw out lubrication oil smoothly and then oil back to compressor oil groove.

 

High Efficiency Advanced Centrifugal Compressor

 

Centrifugal compressor has two-stage compression, internal using high strength alloy main shaft and hermetic impeller, using high precision gear, using non-flat high strength ball/roller bearing; so that emergency stop is ok. Unit start interval can be shortened to 10 minutes, and bearing life can up to 80000 hours.

 

High Efficiency Condenser

 

Condenser is divided into two parts, guide plate installed in the middle that can guide liquid refrigerant to the shell edge, can greatly improve lower copper pipe heat exchange efficiency. For large tonnage unit, this design is very effective, can reduce condensing Temp. 0.5~1℃.

 

Authority Certificate

 

We have industry’s most advanced test room for centrifugal chiller, this test room has passed China National Accreditation Committee audit qualification (CNAS L5123), strictly complying with GB/T10870-2001, GB/T18430.1-2007; testing capacity up to 3000RT. Before delivery, each unit has done strict full performance test to ensure unit performance.

 

Advanced Control

 

• Micro Computer Control

• Touch Screen Panel

• PID Control

• Perfect Protection Function

• Multiple Anti Surge Function

• Reserve Connecting Port for Use

 

Applications

 

Hotel, Hospital, Pharmaceutical, Theater, Stadium, Recreation Center, Commercial Building, Office Building, Industrial & Mining Enterprises, Textile, Chemical, Food and Electronic Research.

 

 

 

 

 

 

 

 

Hot Products

68kW R410A Refrigerant Air Cooled Modular Chiller with DANFOSS Compressor Specifications: EKAC ...
R410a air cooled modular chiller 68KW/90KW/95KW/100KW/134KW/150KW Specifications: Basic Model ...
Features 1. Copeland scroll compressor or Danfoss scroll compressor 2. Plate heat exchanger or shell ...
Totally Heat Recovery Air Cooled Modular Chiller 130KW Features 1. Copeland scroll compressor or ...
Tropical area air cooled scroll chiller max working ambient temperature 56 C Features 1. 4 nos ...
EVI air cooled scroll chiller Features 1. 4 nos Copeland scroll compressors 2. Plate heat exchanger ...