EA-50 incinerator are designed to burn many types of medical waste including type IV pathological waste and infectious and contaminated “Red bag” ,nozzle, plastic items , plastic caps, cellulose acetate membrane electrophoresis, liquid, toilet boxes, bacteria culture, drug sensitivity reaction plate, syphilis test board, other experimental specimens, operation resection stump, organ and so on

Equipment Technical Specifications

Applicable hospital size (number of beds)

100-200

Burning Ability

30-50kg/hour (daily incineration 3-6 times)

Size of the incinerator

1.8×1.15×3 m

Volume of incinerator

Gasification room 0.5m3,secondary burning chamber 0.3m3, mix burning chamber 0.04m3

Size of the waste filling entrance

620×800

Chimney

Height 10m,diameter Ø280㎜

Air Blower

0.37 kw

Auxiliary burner

Power 0.11kw,oil consumption volume 4-10㎏/h

Re-burning burner

Power 0.11kw,oil consumption volume 4-10㎏/h

Operation voltage

380V or 220V

weight

About 4000kg

Main Features:

Fast ,complete ,efficient waste disposal

Ø Primary chamber:0.5cubic meters

Ø Threechambers and two burner, insulated and refractory lined secondary chamber with exit temperature

of up to 1000-1300℃with 2 secondsretention time.

Ø Easy and safe operation:

Ø With temperaturemonitoring function

Ø insulated and refractory lined chamber, and with thickness of refractory more than150mm

Ø Low temperature outside service when incineration

Ø Electric ignition and shut off. With burner slide and the burner can be take out after work finished so that to

avoid the damage to burner.

Ø Automatic controlthe working oftwo burners, the water pump and the fan.

Ø Automatic display ofvoltage and current,temperature in first chamber and second chamber

Ø With secondary chamber and burner, provides a 2 second and gas retention time.

Ø Virtually smoke & smell free

Ø High temperature, refractory lining giving excellent heat retention

Ø Easy installation and maintenance–installation

Ø One year warranty and full access to technical backup and support via telephone.

Ø Worldwide coverage.



Hot Products

FMD25 Medical waste shredder/Clinical waste shredder Main Feature: 1 Double shaft This machine ...
FMD25 Medical waste shredder/Clinical waste shredder Main Feature: 1 Double shaft This machine ...
Needle syringe hub cutter /manual hub cutter/manual needle destroyer FSD-300 Functions: This ...
30L waste bin/ trash bin/ garbage bin/indoor bin/plastic bin /dust bin/medical waste bin FA-BP30L ...
1100 Liters galvanised steel waste bin with dome lid Model:FA-WG1100R 1100 Liters galvanised steel ...
120Liters medical waste bin with pedal FA-BPW120L Description: 120Liters waste bin with various ...