Home Companies ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD

36kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor

ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.318 Shengli Road, Xixi Village, Huheng Industrial Zone, Yueqing City, Zhejiang Province.

Contact name:Meng

Inquir Now

ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

36kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor

Country/Region china
City & Province zhejiang
Categories Other Switches
InquireNow

Product Details

Hot sale 12KV safety indoor AC high voltage load breaker switch

Product Description

 

Key benefits

Efficient solution for transformers protection
Easy application in wide range of configurations
Smart grid and network automation ready
Capability for protection of up to 3000kVA 36 kV transformers
Full range protection in combination with CEF-S fast acting current limiting fuses
Safe and reliable solution for short circuit currents interruptions

ltemUnitData
Rated voltageKVFN12-12D/630FN12-12(R)D/125
Rated frequencyHZ12
Rated currentA50
1min power frequency withstand voltageKV42 to ground and phases fracture 48
Lightning impulse withstand voltageKV75 to ground and phases fracture 85
Rated thermal stable currentKA
630
100
Rated dynamic stable currentKA
50
Rated switching current(peak)KA
50
50
Rated short-circuit current(expected)KV 
31.5
Maximum breaking current thresholdHZFuse characteratic curve accorting
Minimum breaking currentAFuse characteratic curve accorting
Rated transfer currentKV
50
1.5
Maximum breaking currentKV1.8
Breaking OFF-load transformer capacityKV/A1250
Rated cable charging currentA10
Rated active load current breaking timesTimes10000
Opening time when striker strikesS<0.06
Earth switch thermal current switchKA20(2S)
Thermal stable current of earth switchKA5050
Motor operating power supply voltageVAC/DC 110/220

11kv switch disconnector 36kv load break indoor load break switch 11kv

 
ltemUnitData
FN12-10D/630FN12-10(R)D/125
The total traveling distance of moving contactmm200+8-2
Phase center distance (Before energy storage)mm210±15
Moving contact overtravel distancemm40±2
Auxiliary contact opening distancemm>150
Opening/Closing time difference among three phasems<3
Opening speedm/s>2.8>2.8
Closing speedm/s>3.8
Distance between metal flexible door and torchmm>125
Fracture distance of earth switchmm>150
Main circuit resistanceΩ<120<300
Maximum operating torqueNM>160

11kv switch disconnector 36kv load break indoor load break switch 11kv

 

 

Hot Products

400A 11-15KV High Voltage Drop Out Fuse Cutout in poloymer material​ Product Description It is ...
400A 33KV High Voltage Drop Out Fuse Cutout in poloymer material Product Description The Fuse Cutout ...
400A 30-36KV High Voltage Drop Out Fuse Cutout in poloymer material Product Description How a Fuse ...
High Voltage 400A 11KV Drop Out Fuse Cutout in poloymer material Product Description How a Fuse Is ...
11kv Porcelain Expulsion Drop Out Fuse High Voltage IEC Standard Available 11kv drop out fuse high ...
CUTOUT FUSE high voltage fuse link Product Description drop-fuse installation of the technical ...