20kv 24kv Hv High Voltage Isolator Switch Electrical High Efficiency

Country/Region china
City & Province zhejiang
Categories Other Switches
InquireNow

Product Details

20kv load break switch h.v. electrical load break switch 24kv break switch

Product Description

  

 

Disconnect switches can be supplied with equipment to provide a limited load switching capability. Arcing horns, whips, and spring actuators are typical at lower voltages.

These switches are used to de-energize or energize a circuit that possesses some limited amount of magnetic or capacitive current, such as transformer exciting current or line charging currents.

An air switch can be modified to include a series interrupter (typically vacuum or SF6) for higher voltage and current interrupting levels.

These interrupters increase the load break capability of the disconnect switch and can be applied for switching load or fault currents of the associated equipment.

ltemUnitData
Rated voltageKVFN12-12D/630FN12-12(R)D/125
Rated frequencyHZ12
Rated currentA50
1min power frequency withstand voltageKV42 to ground and phases fracture 48
Lightning impulse withstand voltageKV75 to ground and phases fracture 85
Rated thermal stable currentKA
630
100
Rated dynamic stable currentKA
50
Rated switching current(peak)KA
50
50
Rated short-circuit current(expected)KV 
31.5
Maximum breaking current thresholdHZFuse characteratic curve accorting
Minimum breaking currentAFuse characteratic curve accorting
Rated transfer currentKV
50
1.5
Maximum breaking currentKV1.8
Breaking OFF-load transformer capacityKV/A1250
Rated cable charging currentA10
Rated active load current breaking timesTimes10000
Opening time when striker strikesS<0.06
Earth switch thermal current switchKA20(2S)
Thermal stable current of earth switchKA5050
Motor operating power supply voltageVAC/DC 110/220

20kv load break switch h.v. electrical load break switch 24kv break switch

 
ltemUnitData
FN12-10D/630FN12-10(R)D/125
The total traveling distance of moving contactmm200+8-2
Phase center distance (Before energy storage)mm210±15
Moving contact overtravel distancemm40±2
Auxiliary contact opening distancemm>150
Opening/Closing time difference among three phasems<3
Opening speedm/s>2.8>2.8
Closing speedm/s>3.8
Distance between metal flexible door and torchmm>125
Fracture distance of earth switchmm>150
Main circuit resistanceΩ<120<300
Maximum operating torqueNM>160

20kv load break switch h.v. electrical load break switch 24kv break switch

 

  

Hot Products

400A 11-15KV High Voltage Drop Out Fuse Cutout in poloymer material​ Product Description It is ...
400A 33KV High Voltage Drop Out Fuse Cutout in poloymer material Product Description The Fuse Cutout ...
400A 30-36KV High Voltage Drop Out Fuse Cutout in poloymer material Product Description How a Fuse ...
High Voltage 400A 11KV Drop Out Fuse Cutout in poloymer material Product Description How a Fuse Is ...
11kv Porcelain Expulsion Drop Out Fuse High Voltage IEC Standard Available 11kv drop out fuse high ...
CUTOUT FUSE high voltage fuse link Product Description drop-fuse installation of the technical ...