Home Companies ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD

Safety Vertical Break Disconnect Switch 11KV 630A Porcelain Material Type

ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD

Contact Us

[China] country

Trade Verify

Address: No.318 Shengli Road, Xixi Village, Huheng Industrial Zone, Yueqing City, Zhejiang Province.

Contact name:Meng

Inquir Now

ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Safety Vertical Break Disconnect Switch 11KV 630A Porcelain Material Type

Country/Region china
City & Province zhejiang
Categories Other Switches
InquireNow

Product Details

11KV Outdoor Gang Isolator Disconnecting switch type RH-B /Air break swithes

 

 

High-Voltage Protective Equipment


Gang-Operated, Air-Break Disconnect Switch Picture The first device encountered in a substation is typically a disconnect switch.

The most commonly used switch in small to medium substations is a gang-operated, air-break disconnect switch. "Gang-operated" because the three separate switches for each phase are operated as a group from a single control; "air-break" because the switch operates in air rather than in another medium, such as oil.

The purpose of this switch is to disconnect the substation from the incoming line, not to disconnect the transformer from the load. It is like a large safety switch with no load breaking capability. It can only break, or "interrupt" the relatively small "magnetizing current" of the substation transformer. (This is the small amount of current needed to set up the magnetic field in the transformer core.) A substation must first be disconnected from its secondary or load side before the primary or high voltage side can be disconnected using the disconnect switch. High Voltage Power Fuses Picture

Outdoor AC switch disconnector 11kv/400A - 33kv/600A used in 3 phase AC 50/60Hz power circuit, it is used as switching on and switching off at the voltage with no load. It apply to IEC standard. IEC60964:1996, IEC62271-102:2002.

Features:Manufacture according IEC standards.Up to 36kV,900A,200kV BIL.Three phase disconnector.Porcelain and polymer type insulator.Manual and electric drivers.

RH-B - 33KV Series High Voltage Isolating Switch 11-33KV switches disconnector

RH-B - 33KV Series High Voltage Isolating Switch 11-33KV switches disconnector

Hot Products

400A 11-15KV High Voltage Drop Out Fuse Cutout in poloymer material​ Product Description It is ...
400A 33KV High Voltage Drop Out Fuse Cutout in poloymer material Product Description The Fuse Cutout ...
400A 30-36KV High Voltage Drop Out Fuse Cutout in poloymer material Product Description How a Fuse ...
High Voltage 400A 11KV Drop Out Fuse Cutout in poloymer material Product Description How a Fuse Is ...
11kv Porcelain Expulsion Drop Out Fuse High Voltage IEC Standard Available 11kv drop out fuse high ...
CUTOUT FUSE high voltage fuse link Product Description drop-fuse installation of the technical ...