Home Companies State (Beijing) Medical Technology Co., Ltd.

Ground-Based Digital High Frequency X-Ray Radiography System For Medical STT-F50DR-A

State (Beijing) Medical Technology Co., Ltd.
Active Member

Contact Us

[China] country

Address: Room D312,Floor 3,Building 3,Jia 2 Jinfu Road,Economic Development-area, Daxing District,Beijing,China.

Contact name:Cathy Wu

Inquir Now

State (Beijing) Medical Technology Co., Ltd.

Ground-Based Digital High Frequency X-Ray Radiography System For Medical STT-F50DR-A

Country/Region china
City & Province beijing beijing
Categories Laser Pointers
InquireNow

Product Details

Ground-based Digital High Frequency X-ray Radiography System for Medical STT-F50DR

 

High Frequency Generator

1 Functions: Digital x-ray radigography, x-ray filter radiography, buck stand radiography, ARP and AEC.

2 Nominal electric power: 50 kW

3 Tube volate: 40kV~150kV

4 Tube current: 10mA~630mA

5 Time: 2ms~10s

6 mAs: 0.1mAs~630mAs

7 Working frequency: ≥400kHz

8 Control panel: LCD touch screen

 

 

X-ray Tube

1 Max. Tube voltage: 150kV

2 Focus:Small focus:0.6mm; Big focus:1.2mm

3 Anode input power: small focus 19kW, big focus 50kW

4 Target angle: 12°

5 Anode RPM:2800rpm

6 Heat capacity: 150kHU

 

 

 

Flat Panel Detector

 

1 GOS & Csl

2 Size: 35×43cm(14×17 inch)

3 Pixel: 140μm

4 Pixel matrix: 2560×3072

5 A/D conversion: 16Bit

 

 

Radiography Table

1 Size: 2100mm×825mm×655mm (LxWxH)

2 Horizontal moving range: ≥250mm;

3 Lengthways moving range: ≥825mm;

4 Table top lock: Electromagnetic lock, braking force≥100N, with pedal switch, flexible and convenient.

5 With electric or manual control of mechanical movement, and there is automatic tracking alignment function with the x-ray tube and the detector.

6 Grid size: ≥15"×18";Grid focus distance: f0=100cm; Grid ratio: r=10 :1;Grid density: N=103Lines/Inch

 

 

Tube Column

1 Secure and solid structure

2 Column rotation: ≥±180°

3 Moving range along the table: ≥1575mm, can be locked at any point

4 Tube moving up & down: 930mm±10mm, an be locked at any point

5 Tube rotation: ≥±180°

6 Max. Distance from tube focus to film: ≥1200mm

 

 

 

Bucky Stand

1 Up & Down moving range: ≥1200mm;

2 At max. Height, the distance between the floor and the box center is ≥1500 mm;

3 Grid size: 18×18";Grid focus: f0=180cm;Grid ratio: r=10 :1;Grid density: N=103Lines/Inch

 

 

Collimator

Flexible and convenient to operate, and any rectangle radiography field size is available.

 

 

Imaging

Packing List (STT-F50DRA)

NO.

Part Names

Qty

 

Remarks

1

High Frequency Generator

1 pc

 

 

2

Control Panel

1 pc

 

 

3

X-ray Tube

1 set

 

 

4

Collimator

1 pc

 

 

5

Flat Panel Detector with Software

1 set

17*17

 

6

Bucky Stand

1 pc

 

 

7

Radiography Table

1 pc

 

 

8

Workstation (Computer)

1 set

--

 

9

Grid

2 pc

18"×18"

JPI

10

High Voltage Cable

1 pair

75kV

 

 

Hot Products

Good Use Single ENT Treatment Unit For Hospital / Clinic Surgical Room With Perfect Feedbacks As a ...
750×485×860mm Marble Desktop Small Single ENT Unit With Perfect X Ray Viewer Box Technical Parameter...
New Style ENT Treatment Unit with Camera system Well Accepted in Hospital and Clinic size 1650mm...
Hot Sale Blue or Orange Color Marble Desktop ENT Treatment Unit With Image Processing System ...
New Product Single ENT Treatment Unit Well Accepted by Hospital and Clinic Surgical Room Main ...
Double Single Station ENT Treatment Unit for Ears, Nose and Throat surgical in Hospital or Clinic ...