Home Companies Shenzhen Zhenhua Qunying Electronics CO. ,Ltd.

48 Volt Dc Switching Contactors Coil Curren For Communication Industry

Shenzhen Zhenhua Qunying Electronics CO. ,Ltd.
Active Member

Contact Us

[China] country

Address: Room 601, building no.7, no.3 industrial zone. South of the village community of the citizens streed of guangming new district,Shenzhen

Contact name:Emily

Inquir Now

Shenzhen Zhenhua Qunying Electronics CO. ,Ltd.

48 Volt Dc Switching Contactors Coil Curren For Communication Industry

Country/Region china
City & Province shenzhen guangdong
Categories Car Chargers
InquireNow

Product Details

JQ - 50H(B) / 48 - 48AW Rate Current 50a Normal Open 48v Single Coil Magnetic Contactor For Communication Industry

 

1. Summary

JQ-50H(B)/48-48AW DC contactor has a set of bridge normally opened contactors with load current up to 50A. Accord with GB1408.4-2003/IEC60947-2003, YD/T585-2010. Suitable for communication power equipment electrical control device.

 

2. Order mark standard

JQ - 50H(B)/ 48 - 48AW

JQDC Ccontactor
50Rated load 50A
HNormally open
(B)Communication power
BDouble coil
48The contact voltage
48The contact voltage
WBending mounting plate

 

3. Usage condition

Ambient temperature: work: - 40 ~ + 60; storage and transportation: - 40 ~ + 70
relative humidity: 98% at 40
altitude: not more than 2000 meters.

Vibration: 10-55hz,
amplitude: 0.35mm
impact: 30m/s2

 

4. Standard,safty and environmental protection

(1) Comply with GB14048.4-2003 / IEC60947-4-1:2000 low voltage switching equipment and control equipment electromechanical contactor and motor starter standard.

(2) YD/T585-2010 General credit distribution equipment technical conditions.

 

5. Parameter table

ParameterCoil voltage of contact circuit
Voltage range6-220v
Coil power5-8w
Normal state 
Main rated load current of contact circuit100A
Rated voltage of contact circuit6-80v
Sucking time40ms
Releasing time30ms
Mechanical life100000times
Electric life1000times
Coil resistance603.6-708.4Ω

 

 

6. JQ-50H(B)/48-48AW current curve

 

7. The circuit diagram of the configuration, installation and terminal

 

8. What's the difference between High voltage DC contactor and low voltage DC contactor?

with the small current switch control of high-current electrical appliances, operating to reduce the risk factor, the contactor can achieve remote control, maily used in the frequent start of the device.

The realization of small current switching control of high current electrical appliances and to achieve the control loop and the main circuit isolation.

 

9. Series of DC contactor Pics 

9. DC Contactor Application range

Hot Products

JQ - 50H(B) / 48 - 48AW Rate Current 50a Normal Open 48v Single Coil Magnetic Contactor For ...
Low Voltage Electromagnetic Normal Closed Single Coil 50 Ampere 48v Direct Current Contactor 1. ...
High-current Load Devices 200 Ampere Series 24,48,54,62 Voltage Double Coil Single Pole Normal Open ...
Rate Current 400 Ampere 48 Voltage Normal Open Double Coils Dc Contactor Welding Arc Suppression 1. ...
An Electrically Controlled Switch Rate Current 600a 48v Normal Close Doulbe Coils Dc Contactor 1. ...
A Circuit Breaker 600 Ampere 48 Voltage Normal Open Double Coils Dc Cotactor For Communication Power ...