Data Rack Cabinet and Server Racks Cabinets in field of telecommications YH14

In the traditional concept, the traditional definition of the cabinet in the data center room is that the cabinet is a carrier of network equipment, servers and other equipment in the data center room. So, with the development of the data center along the way, the use of cabinets in the data center room is changing? Yes. Some manufacturers specializing in computer room products, in view of the current situation of the development of data center computer room, gives the cabinet more functions.
1, improve the overall beauty of the room a variety of appearance
Under the standard of 19 - inch equipment installation width, several manufacturers have innovated the appearance of the cabinet, and considering the appearance effect of the cabinet under the environment of single-unit placement and multiple - unit placement, take dinglong company as an example, they have increased the aluminum profile cabinet from the appearance, and designed various appearances on the basis of the original steel profile cabinet, such as arc mesh door cabinet, arc mesh door cabinet, concave-convex mesh door cabinet, etc.
2, realize the intelligent management function of the cabinet intelligent cabinet
In order to meet the high requirements of the operating environment and safety of the cabinet in the data center room, the cabinet with intelligent system is required to meet the relevant requirements. The main intelligence is reflected in the diversity of monitoring functions:
( 1 ) temperature and humidity monitoring function
The intelligent cabinet system is internally provided with a temperature and humidity detection device which can intelligently monitor the temperature and humidity of the internal environment of the regulated power supply system and display the monitored temperature and humidity values on a monitoring touch screen in real time.
( 2 ) smoke detection function
The smoke detector is installed in the intelligent cabinet system to detect the fire status of the intelligent cabinet system, and when the abnormal situation occurs in the intelligent cabinet system, the relevant alarm status can be displayed on the display interface.
( 3 ) intelligent heat dissipation function
The user can set a set of temperature ranges for the regulated power supply system according to the temperature environment required by the equipment in the cabinet for operation, and when the temperature in the regulated power supply system exceeds the range, the heat dissipation unit is automatically started to work.
( 4 ) system status detection function
The intelligent cabinet system itself has its working status and led indicator light display of data information collection and alarm, and can be visually displayed on the LCD touch screen, and the interface is beautiful, generous and clear.
( 5 ) intelligent equipment access function
The intelligent cabinet system has access to intelligent equipment, including intelligent power meter or ups uninterrupted power supply, reads corresponding data parameters through RS485 / RS232 communication interface and Modbus communication protocol, and displays them on the screen in real time.
( 6 ) relay dynamic output function
When the linkage of the pre-designed system logic is received by the intelligent cabinet system, a normally open / normally closed message will be sent to the do channel of the hardware interface to drive the equipment connected to it to work, such as audible and visual alarm, fan and other equipment.
3. intelligent air supply cabinet capable of save energy consumption of machine room operation
Users must solve the following problems: communication equipment due to work and heat, will accumulate a lot of heat in the cabinet, affect the stable operation of the equipment. The intelligent air supply cabinet can adjust the configuration according to the condition of each cabinet ( such as the number of installation equipment, the requirements on the infrastructure such as air conditioning, power supply, wiring, etc. ), thereby avoiding unnecessary waste, saving initial investment and energy consumption, and bringing greater value to users. In addition, the value of intelligent air supply cabinet products is also reflected in full-load support of equipment. In general, traditional cabinets cannot be fully equipped with equipment such as servers, because once a large number of equipment is installed, it is likely to cause local overheating of the cabinet, resulting in server downtime within the cabinet. Each cabinet in the intelligent air supply cabinet solution is independent, and the equipment can be cooled according to the operation condition of the equipment of the cabinet, so as to realize the full-load operation of the cabinet, thereby greatly saving the space requirement of the machine room and reducing the cost of enterprises. Compared with the common cabinet, the intelligent air supply cabinet can save about 20 % operation cost, and the energy saving effect is remarkable.

 

A complete set of new generation network cabinet system mainly includes cabinet main body, airflow management unit, cable management unit, power distribution unit, installation fixed accessories, KVM switch and rack LCD display, etc.
First, the cabinet system base wood requirements
In the late 1970s, businesses began installing computers in cabinets. However, installation is difficult due to incompatible equipment between multiple vendors. In 1984, the international electrotechnical commission ( iec ) adopted iec 297 - 3, which specifies a standard physical size of 482.6 nun ( lgin ) for cabinets. Other standards, such as EIA 310, further establish standards for rack-mounted telecommunications and it equipment. Despite the establishment of these standards, the continuous progress of the computer industry and its continuous integration with the telecommunications industry has created new problems, namely, the significant lag of these standards. This section systematically describes the identification and classification of user issues, and in-depth analysis of the nature and characteristics of the next generation of key business facilities cabinet system.
This section systematically analyzes the customer's problems with the cabinet system and points out the direction of the next generation of critical business facilities. The current design ideas and equipment are not solved, the most urgent problems have a common core problem, that is, the data center or network room to adapt to the poor cultural ability. Cabinet systems must be more adaptable to changing requirements in order to improve their availability and cost - effectiveness.
In many industries, with the progress in reliability, cycle, cost, standardization, pre-engineering and module requirements to further improve, the industry has reached a certain level of maturity. Designers and facility owners of critical business facilities and the cabinet systems they use should consider whether this requirement is met.
Ii. cabinet components
A complete set of next generation cabinet system mainly includes cabinet main body, airflow management unit, cable management unit, power distribution unit, installation fixed accessories, KVM switch and rack LCD display, etc. The cabinets referred to in this section generally refer to the cabinet body unless otherwise specified.
( a ) the cabinet body
Cabinet bodies that meet the design requirements of modern core machine rooms typically have the following characteristics.
( 1 ) the ventilation area of the front and rear doors shall not be less than 5355 cm2, meeting the ventilation requirements specified by the main server manufacturer.
Cabinet front door meeting ventilation area requirements
( 2 ) the vertical installation column can be adjusted conveniently to meet the requirements of equipment with different installation depths.
( 3 ) all EIA - 310 - d compliant equipment can be properly installed.
( 4 ) the integrated rear cable management dedicated channel allows users to easily lay, manage, and operate a large number of data cables, even if rack equipment is installed in the cabinet or if the cabinet is installed in parallel.
( 5 ) through the rear power distribution channel, users can easily install multiple models of vertically installed power distributor ( PDU ) without occupying valuable cabinet effective installation space. Special power distribution channel, convenient power distribution operation, at the same time
A greater number of power outlets are provided for cabinet mounting equipment, and no less than 21 iec power outlets can be provided in the power distribution channel on one side of the cabinet.
( 6 ) the power and data lines can come from the cabinet at the top of the cable tray, also can come from the lower space of overhead floor, so the cabinet top and bottom of the cabinet need to provide sufficient cable into the channel. In some use environments, power or data lines may need to be routed from one cabinet installed side-by-side to an adjacent cabinet, and side cable access ports may need to be provided on the routing channels at the rear of the cabinet to accommodate such use.
( 7 ) the cabinet on the vertical installation column marked the accurate position of each " u", eliminate the trouble of the user repeatedly find installation position, greatly facilitate the user's installation work.
( 8 ) the front door, rear door and side plate can be locked, and can only be opened with the key provided.
( 9 ) proven frame design, robust standard mounting rods, and heavy duty wheel feet provide static and dynamic load levels of not less than 900 kg.
( 10 ) set up multiple grounding bolts, for the equipment installed in the cabinet and all independent metal parts to provide sufficient ground.
( 11 ) front, rear and side panel design for quick removal. Removal of cabinet doors or side panels can bring unexpected convenience during equipment installation and routine maintenance.
( 2 ), airflow management unit
The air flow management unit is mainly use for preventing air from circulate repeatedly in that cabinet and improving the refrigeration efficiency of the machine room. Usually divided into passive and active mode.
1. passive airflow management unit
Passive airflow management units typically employ passive components to vary the distribution of airflow. For example, blind flanges can be quickly and easily installed in EIA - 31019 in. racks or cabinets with square mounting holes by occupying unused rack space to facilitate proper airflow within the cabinet and using a modular, tool-less design.
The metal bezel is used in the case of threaded rails, and the brush bar allows the cable to pass from the front of the rack to the back of the rack while blocking airflow.
Air recirculation is prevented by occupying unused rack space using an airflow steering baffle kit consisting of Lu, 2u, 4u, 8u baffles.
2. active airflow management unit
Active airflow management units typically employ active devices to vary the flow of airflow in the cabinet. Depending on the function, there are the following.
( 1 ) side-to-side airflow distribution. Rack equipment with lateral air flow presents a number of challenges to it facility managers, especially in refrigeration. Because most cabinets are designed in the form of air flow from front to back, it is difficult to maintain the desired operating temperature in laterally ventilated equipment. Cabinet - side air supply units allow for better safety and construction, allowing cabinets to be placed side-by-side one after another without preventing air flow.
Cabinet - side air supply units are typically 2u cabinet-mounted air supply products for lateral air flow between network equipment or servers. It draws the conditioned temperature and humidity air from the front of the cabinet and sends it to the airflow inlet on the side of the network equipment. In this way, the life of the apparatus is prolonged by supplying the appropriate inlet temperature.
A: yes, sir
The product is recommended for one or more network devices stacked continuously in a cabinet. The cabinet - side air supply unit may be placed above or below the network equipment, and the user may configure the air flow mode through interchangeable air flow guide vanes.
( 2 ) rear airflow management. In high-density device environments, conventional heat dissipation methods are generally inefficient. High - density installed cabinets can cause it equipment to overheat and cause downtime. Rack exhaust collects hot air from the exhaust and returns it to the ventilation duct, eliminating hot spots in the data center. Through the automatic fan speed adjustment mechanism based on temperature, the fan can automatically adjust the speed for optimal performance. The LCD display installed on the device allows the user to view rack temperature, monitor alarm conditions, and adjust device settings. The integrated network management card enables remote monitoring and control of rack exhaust equipment. This space-saving product is installed on the back of the cabinet that meets the requirements and does not occupy mesa space.
( 3 ) front airflow management. Rack front air distribution equipment is a unique rack mounted fan tray product that is used with existing precision air conditioning systems to deliver cold air to equipment within the enclosure. The air distribution equipment is connected with the movable floor, and the supplementary air is directly sent into the casing, so that the air distribution equipment can not be mixed with external hot air before reaching the equipment needing refrigeration.
The rack air distribution device eliminates temperature differences between the top and bottom of the enclosure and prevents high temperature exhaust gases from re-circulating from the inlet to the enclosure.
For rack enclosures, a rack air conditioning device with a rated load of more than 1.5 kw is appropriate and can provide airflow at a maximum of 3.0 kw. If the underground air conditioning equipment does not meet the requirements of the nearby telecommunication equipment, the above equipment shall be used additionally on the living floor.
Iii. cable management unit
Racks and cabinets can accommodate more equipment than ever before, and this increase in equipment density requires orderly cable management inside and outside the rack. Poor management of the cable may not only result in damage to the cable or increase the time required to replace the cable, but may also impede the passage or arrival of the main airflow, resulting in degraded equipment performance or even downtime. These accessories provide suitable cable management solutions for a variety of needs, from simple cable management rings, vertical or horizontal finishing panels to trunking and cable ladders.
According to the function can be divided into the following.
( 1 ) cable ladder. Usually used for overhead cable management between cabinets, commonly used size has width of l5cm and 30cm. In practical applications, the cable ladder is commonly referred to as a pair of use, one for data transmission and the other for power transmission, and the spacing distance is not less than l5cm.
( 2 ) cable channel. Cable channel is used for cable management outside the cabinet, usually installed at the top of the cabinet, generally installed at least 2 channels, respectively, for data cable and power cable management.
Cable channel assembly
( 3 ) horizontal cable management, that is, cable management inside the cabinet.
( 4 ) vertical cable management, that is, cable management inside the cabinet.
Iv. power distribution unit
The power distribution unit typically occupies an empty l room of the Lu or 0u cabinet
To provide not less than 21 power outlets for the entire cabinet. Power socket adopts the international general cl3, c19 standard, the maximum current value provided by a single power distribution unit is not less than 32a, and provide overload or short circuit protection.
Optional metering power distribution units provide advanced warnings to prevent accidental power overload. Once the user-defined alarm threshold is exceeded, local and remote real-time alarms can be issued for unexpected circuit overloads that may exist in mission-critical equipment, reducing risk. The metered rack PDU provides power utilization trends that allow data center managers to make informed decisions about the proper sizing of their it environments.
V. installation of fixed fittings
Mounting fixtures include stabilizing plates, keyboard drawers, light and heavy duty brackets, bolt lock brackets, ground straps, mounting rails, brackets, and associated hardware.
 

 

 

 

-We accepted sample and tested,we can supply you samples if you want;

-Our products is OK for series of test,quality is no problem;

-We build QC department and experimental lab,we try to make high quality items;

-We enjoy to be very high trust factory in China,and local administration always give honour to us;

-In 2018,we build new export department,we want to have good start with every distributors and project company,we want to have direct cooperation.

-We now have new production area,with good convenient conditions,and high efficient workshop;

-We have active team,including management and trading,of course with production;

-We have standard warehouse system,we try to keep less stock to let business running fast;

-We can delivery by sea,and by air,if you need any means,we all accepted;

-Let us have a nice start,please type you idea;

-Established In 1995,we are the leading manufacture of telecommunication parts and equipment in China;

-In past years,100% products is exported to over 50 country in the world,we enjoy high quality and best service and flexible production schedule,meeting your demands;

Hot Products

Customized Mini Network Server Cabinet Steel Networking Rack Cabinets YH2008 Quick Detail: 1. ...
Glass Door Server Rack Cabinet 100mm Depth Cold Rolled Steel With Powder Coat Finishing YH2002 Quick ...
Home Wall Mount Network Rack Cabinet Lockable 19 Inch 0.6m / 1m Depth YH2006 Quick Detail: 1. ...
FTP UTP Blank Patch Panel , 24 Port Cat5e Patch Panel With Cable Manager YH4020 Quick Detail: 1. ...
BT Style UK Telephone Test Cable ABS PBT Material With RJ11 6P4C Modular Plug YH5009BT1 Quick Detail...
Cat.5e Rj45 Home Ethernet Network Patch Panel for 12 Port / 18 Port YH4007 Quick Detail: 1. Category ...