Shanghai Zhoubo welding & cutting technology CO.,LTD. |
Verified Suppliers
|
|
Kjellberg Swril Gas Cap .11.848.401.1545 G4345 For Hifocus Plasma
Cutter Machine
Our company adopts modern management mode and devotes itself to new
high performance design and production of welding & cutting
equipments, with continuous technique advantages innovation .All
our staff are striving to realize the aim of "Create Chinese Brand
,Build First-Class Enterprise ",with the spirit of "Being honest
and pragmatic ,making pioneering efforts and seeking perfection
with persistency."
Company commitment: thinking what customers think, worrying what
customers worry, in time delivery and high tracking service.
1. Can supply various models of plasma Consumables electrode,
nozzle, shield, swirl ring, inner cap, retaining cap, water tube,
torch body, such as HT4400, HPR400XD, HPR260XD, HPR130XD, HPR260,
HPR130, HSD130, HD3070, HD4070, HT2000, MAX200, POWERMAX1650,
POWERMAX1250, POWERMAX65, POWERMAX85, POWERMAX45, POWERMAX30 and so
on.
2. Can make as per customer's requirements. Almost Every Parts Have
A Lot Of Stock.
3.The strict quality control. Our products processed are using CNC
machines, we have fifteen sets of high-precision testing equipment
and Eighty experienced skilled workers.
Machine | HEC NO. | Thum NO. | Ref NO. | Description |
| K94231 | G971 | .11.848.211.142 | Cooling tube |
K0424 | G044 | 11.848.211.530 | Cathode | |
K0422 | G042 | .11.848.211.510 | Cathode ArH2 | |
K7441 | G101 | .11.848.221.145 | Gas guide | |
K14610 | G2010 | .11.848.221.410 | Nozzle O2 80A | |
K541208 | G3008 | .11.848.201.1608 | Nozzle cap | |
K541218 | G3018 | .11.848.201.1618 | Nozzle cap | |
K641522 | G4022 | .11.848.201.1522 | Swirl gas cap | |
K641525 | G4025 | .11.848.201.1525 | Swirl gas cap | |
K0432 | G052 | .11.848.311.510 | Cathode | |
K7445 | G105 | .11.848.221.149 | Gas guide | |
K141016 | G2516 | .11.848.311.616 | Nozzle | |
K641830 | G4530 | .11.848.311.1530 | Swirl gas cap | |
K44191 | G501 | .11.848.201.081 | Protective cap | |
K04261 | G071 | .11.848.411.500 | Cathode ArH2 | |
K74255 | G125 | .11.848.421.149 | Gas guide | |
K141125 | G2725 | .11.848.411.625 | Nozzle ArH2 | |
K141127 | G2727 | .11.848.411.627 | Nozzle ArH2 | |
K141129 | G2729 | .11.848.411.629 | Nozzle ArH2 | |
K541409 | G3209 | .11.848.401.1609 | Nozzle cap | |
K541419 | G3219 | .11.848.401.1619 | Nozzle cap | |
K541429 | G3229 | .11.848.401.1629 | Nozzle cap | |
K541449 | G3249 | .11.848.401.1649 | Nozzle cap | |
K641735 | G4330 | .11.848.401.1530 | Swirl gas cap | |
K641745 | G4335 | .11.848.401.1535 | Swirl gas cap | |
K641740 | G4340 | .11.848.401.1540 | Swirl gas cap | |
K641745 | G4345 | .11.848.401.1545 | Swirl gas cap | |
K641750 | G4350 | .11.848.401.1550 | Swirl gas cap | |
K641755 | G4355 | .11.848.401.1555 | Swirl gas cap | |
K44201 | G521 | .11.848.401.081 | Protective cap | |
K94211 | G901Y | .11.848.201.142 | Water Tube | |
K94212 | G902Y | .11.852.201.142 | Water Tube | |
K94241 | G931Y | .11.848.401.142 | Water Tube |
Technical Support:
plasma cutting arc fault analysis
1. air pressure is too low
Plasma cutting machine work, such as work pressure far below
specifications required pressure, which means that the plasma arc
jet velocity weakening, input the air flow is less than the
specified value, this form of high energy and high speed of plasma
arc, causing the incision quality is poor, cut through, incision
tumor of the product phenomenon. The reasons for the lack of air
pressure: air compressor input is insufficient, the pressure of the
cutting machine air regulator is too low, there are oil pollution
in the solenoid valve, the gas path is not smooth, etc.. The
solution is to use before the observation of air compressor output
pressure display, such as does not meet the requirements, can
adjust the pressure or maintenance of air compressor. If the input
pressure has reached the requirements, should check air filter
relief pressure valve regulation is correct; gauge display can meet
the cutting requirements. Otherwise deal with air filter pressure
relief valve to carry out routine maintenance, to ensure that the
input air dry, no oil. If you enter the air quality is poor, will
cause the oil pollution in the valve, the valve is difficult to
open, the valve port can not be fully opened. In addition, torch
nozzle pressure is too low, the replacement valve; gas road section
variable is caused by pressure is too low, according to the
specifications for tracheal replacement.
2. air pressure is too high
If the input air pressure is far more than 0. 45MPa, after the
formation of the arc ion, the large flow of air will blow
concentrated arc column, the energy of arc column dispersion,
decreased the plasma arc cutting intensity. Cause the pressure is
too high, the reasons are: improper input air conditioning, air
filter regulator is too high or air filter valve failure. The
solution is to check whether the pressure of the air compressor is
adjusted properly, air compressor and air filter pressure relief
valve is dysfunctional. After startup, such as rotating air filter
relief pressure valve adjusting switch, gauge unchanged, indicating
that the air filter relief pressure valve failure, need to be
replaced.